Harman®  •  PF-120 Installation Manual_R1  •  2014 -___  •  03/14

28

3-90-08121i

B. wiring Harness

CF

M @ <.3" ST

ATIC PRESSURE

OR

ANGE MED L

OW

YALL

OW MED HIGH

BLA

CK HIGH

6.8 A

MP M

AX.

FIELD T-ST

AT

WIRING

M

ALE/FEM

ALE C

ONNEC

TION

3/8" FLEX C

ONDUIT

3/8" FLEX C

ONDUIT

DISTRIBUTION BL

OWER

LOW FUEL AUX. OUTPUT *

72B wir

enut (or

ange)

SPLICE IN JUNC

TION BO

X

*  SEE 

YOUR OWNERS M

ANU

AL FOR MORE DE

TAILS

IGNITER ELEMENT 450 

W

AT

T M

AX

LOW PRESSURE SWIT

CH

SK

Y BL

UE

N.O

. C

ONT

ACE

T

18/3 RUBBER C

ORD

FR

OM 

THE UPS *

FEEDER MO

TOR

BLA

CK

120 

VA

C

IGNITER PUMP

MALE/FEMALE CONNECTION

YELL

OW

SK

Y BL

UE

450 

W

AT

T

1132

1368

1516

1638

RED L

OW

120 

VOL

TS A.C. 60 HZ.

900 W

AT

TS

-

1200 W

AT

TS

-

 PELLE

T FURNA

CE 

WIRING DIA

GR

A

M

MAIN JUNCTION BOX

10 AMP CIRCUIT BREAKER

WHITE

RED

10 A

MPS M

AX ( t

est mode )

7.5  A

MPS NORM

AL OPER

ATION

VIOLE

T

SK

Y BL

UE

WHITE

POWER T

O THE 

UPS 

*

120V

AC  60 hz

DRK BL

UE

BLA

CK

120V

AC INPUT

TERMINALS

DRK BLUE

WHITE

WHITE

GREEN

N

L

BR

OWN

DRK BLUE

VIOLE

T

BROWN

BLA

CK

RED

BR

OWN

GREEN

WHITE

WHITE

GREEN

WHITE

BR

OWN

SKY BL

UE

WHITE

RED

BR

OWN

WHITE

BLACK

SKY BLUE

YELLOW

HIGH VOL

TA

GE

YELL

OW

VIOLET

SKY BLUE

WHITE

3/8" FLEX C

ONDUIT

PVC C

ORD MO

TOR LEAD

COMBUSTION MO

TOR

MALE/FEMALE CONNECTION

OR  MED LO
RED  LO

BLK  HI

YEL MED HI

VIOLET (NEUTRAL)

BLACK

VIOLET

P.N. 3-90-73560

CONTR

OL

BLA

CK

VIOLE

T

SK

Y BL

UE

WHITE

N.C.

HIGH LIMIT

INSIDE

N.O

.

FA

N

72B wir

enut (or

ange)

SPLICE IN JUNC

TION BO

X

DRK BL

UE

RED

4" SQU

ARE JUNC

TION BO

X

WHITE

WHITE

SK

Y BL

UE

VIOLE

T

WHITE

RED

BLACK

VIOLE

T

BLA

CK

VIOLE

T

RED

WHITE

GR

OUND

BLACK

VIOLE

T

BLA

CK

BLA

CK

WHITE BL

UE

BL

UE

RED

POLE THERMOST

AT TERMINAL 

BL

OCK

LOW FUEL SENSOR   ( in hopper )

LOW VOL

TA

GE

BL

UE

WHITE-

OR

ANGE

WHITE-BL

UE

YELL

OW

OR

ANGE

BR

OWN

WHITE

WHITE 11 PIN PLUG

FAN C

ONTR

OL

WITH SEPER

ATE F

AN C

ONTR

OL 

AND HIGH LIMIT 

YELL

OW

EMPT

Y

EMPT

Y

EMPT

Y

EMPT

Y

RED

BL

UE

WHITE

BLA

CK

10

5

7

9

8

6

3

4

11

6 A

MP GLASS FUSE

ESP PR

OBE

11 PIN SOCKE

T

TERMINA

TION

 T

WISTED 

WIRE

PL

UGGED

CONTR

OL

ESP 

BO

ARD  

BR

OWN

1

2

4

3

2

1

HOUR ME

TER  

   RESE

T

BLA

CK

SK

Y BL

UE

SKY BLUE

SK

Y BL

UE

Summary of Contents for PF-120

Page 1: ...allation Installation MUST comply with local regional state and national codes and regulations Contact local building or fire officials about restrictions and installation inspection requirements in y...

Page 2: ...s Specifications 4 C Electrical Rating 4 D Mobile Home Approvals 4 E BTU Efficiency Specifications 4 2 Getting Started A Tools and Supplies Needed 5 B Inspect Appliance and Components 5 3 Clearances A...

Page 3: ..._________ Electrical Section 1 Pg 4 120VAC unswitched power provided to the appliance ________________________________ Finishing Sections 3 4 Pg 8 14 Combustible materials not installed in non combust...

Page 4: ...to the frame of the mobile home and use only listed pellet vent Class PL connector pipe A Harman Outside Air Kit must be installed in a mobile home installation MODEL Pellet Furnace PF 120 LABORATORY...

Page 5: ...g the installation to ensure maximum safety and benefit WARNING Risk of Fire or Explosion Damaged parts could impair safe operation DO NOT install damaged incomplete or substitute components Keep appl...

Page 6: ...iagram Dimensions are actual appliance dimensions Use for reference only 14 18 25 966 62 474 15 883 9 743 37 961 18 11 00 65 525 20 065 25 254 16 802 3 215 44 478 WITHOUT BLOWER BOX INSTALLED 27 238 2...

Page 7: ...sh pan door The 18 clearance from the hopper end is a manufacturer s recommendation for adding pellets and or servicing the feeder mechanism The minimum clearance to the top of the plenum is 4 Fig 3 3...

Page 8: ...The United States J Floor Protection Requirements US Sides 8 K Front 18 C Floor Protection The shaded area indicates the required floor protection area The furnace requires 48 x 52 of floor protectio...

Page 9: ...onfiguration Graph under Section B Locating Your Appliance Chimney Each Vertical 90 or T subtract 2 5 feet Each Vertical 45 subtract 1 5 feet Each Horizontal 90 or T subtract 5 0 feet Each Horizontal...

Page 10: ...intain specified clearances to windows doors and air inlets including air conditioners Vents should not be placed below ventilated soffits Avoid venting into alcove locations Vents should not terminat...

Page 11: ...fsets Consider the appliance location relative to floor and ceiling and attic joists DO NOT CONNECT THIS UNIT TOACHIMNEY FLUE SERVICING ANOTHER APPLIANCE May allow flue gases to enter the house CAUTIO...

Page 12: ...regulator assembly when measured from the horizontal center line of the regulator I The clearance to service regulator vent outlet must be a minimum of 6 feet J The clearance to a non mechanical air s...

Page 13: ...ombine with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When...

Page 14: ...nd chimney To measure the draft or negative pressure on your appliance use a magnahelic or a digital pressure gauge capable of reading 0 1 inches of water column W C The appliance should be running on...

Page 15: ...NOT install damaged components Do NOT install incomplete components Do NOT install substitute components Report damaged parts to dealer WARNING WARNING Do not relocate or bypass any of the safety cont...

Page 16: ...y the demands of the pellet appliance but consideration must be given to the total house demand House demand may consume some air needed for the stove especially during a power failure It may be neces...

Page 17: ...is access to the combustion blower and flue area 1 Place the bottom on the floor The edge closest to the knockouts will be the edge towards the furnace See Figure 5 1 2 Place the desired vertical pan...

Page 18: ...bottom middle hole under the filter opening NOTE Do not put any screws into any of the top holes at this time Filter Frame Panel Filter opening must be up 4 Place the remaining panel in this case the...

Page 19: ...sure that the setscrew on the flex connector is not pointing toward the furnace end of the box when the locknut is fully tightened The filter box is now ready to install onto the furnace Note The blo...

Page 20: ...Y DUCT WORK OR IN FREE AIR WILL CAUSE MOTOR OVERLOAD AND PREMATURE FAILURE 3 Mount the filter box on the furnace with 6 10 x 3 4 Tek screws 3 on each side Figure 5 10 Visually locate these holes so yo...

Page 21: ...Orange Blue White Orange White Blue This section is not used on this unit CAUTION With this small gauge of wire care must be taken not to over tighten the terminal screws thus breaking the wire There...

Page 22: ...dampers 2 should be installed in the ductwork 1 in the warm air supply duct for the existing furnace and 1 in the warm air supply duct of the pellet furnace after or downstream of the high limit fan c...

Page 23: ...ct system can be installed to fit the customers needs Velocity 500fpm 700fpm 900fpm Static In W C 3 Minimum to 6 Maximum 1638 cfm 470 in 360 in 290 in These duct sizes are only recommendations The Ret...

Page 24: ...blower size is 75 to 1 CFM for each square foot of conditioned space standard 8 ceiling height This furnace can be fitted with an air conditioning coil mounted in the supply air plenum HHT is not resp...

Page 25: ...t the WHITE and SKY BLUE wires to the LIMIT switch It doesn t matter which wire is on which screw Figure 5 17 8 Make sure that all of the wires are out of the way when closing the cover Excess twistin...

Page 26: ...ply 120 VAC 60Hz power stable enough to operate the control board properly Control board damage could occur Checking Recording the Low Draft After the venting is completed the firebox low draft will n...

Page 27: ...shall comply with CSA B139 The installation of a gas furnace shall comply with the applicable requirements of CSA B365 and if changes are made to the installation of the gas furnace including clearanc...

Page 28: ...WHITE GREEN N L BROWN DRK BLUE VIOLET BROWN BLACK RED BROWN G R E E N WHITE WHITE GREEN WHITE BROWN SKY BLUE WHITE RED BROWN WHITE BLACK SKY BLUE YELLOW HIGH VOLTAGE YELLOW VIOLET SKY BLUE WHITE 3 8...

Page 29: ...Harman PF 120 Installation Manual_R1 2014 ___ 03 14 29 3 90 08121i...

Page 30: ...n U S A Copyright 2012 Harman a brand of Hearth Home Technologies Inc 352 Mountain House Road Halifax PA 17032 www harmanstove com Please contact your Harman dealer with any questions or concerns For...