Harman® • P35i-C Installation Manual_R2 • 2019 -___ • 02/20
9
8390-784i
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 3.2).
WARNING! Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access. Due
to high temperatures, the appliance should be located out of
traffic and away from furniture and draperies.
NOTICE:
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY. Illustrations/diagrams are not
drawn to scale. Actual installation may vary due to individual
design preference.
B. Clearances to Combustibles & Floor Protection
* Floor protection must be used from hearth opening to 6" (152mm) in front of door glass and 6" (152mm) to each side
of the stove body OR 8” (203mm) to sides to protect combustibles from hot ashes. A minimum size will be 8-7/8" deep
by 24-5/8" wide and be made of a non-combustible material or meet UL approval.
Figure 3.2
G
H
F
Location
Inches
Millimeters
F
Minimum Width
24
609
G
Minimum Depth
14-1/2
368
H
Minimum Height #1-70-774235
23-1/2
597
H
Minimum Height #1-70-774195
19-1/2
495
C. Minimum Opening - Masonry and Manufactured Fireplaces
Mantel
Side W
all
Face Trim
A
B
C
E
D
F
Location
Inches Millimeters
A
Insert to combustible sidewall
13
330
B
Surround top to face trim
0
0
C
Surround side to face trim
1
25
D
Insert top to (max) 12" mantel
12
305
E
Door opening to front
6
152
F
Door opening to side
6
152