8

SDEC-4500

The SDEC-4500 comprises two units. Both the SDEC-4500P and SDEC-4500X are 

required

for the digital equalizer 

to function properly in the Synthesis system. Please be sure to connect both units correctly according to the
Input/Output Assignments chart on page 9. 

The correct Synthesis Interconnect kit includes all the necessary connections for using the SDEC in the Synthesis
system. Please be sure to order the S3000IC or S3000XLRIC for use with SDEC-3000 and S4000IC or S4500XLRIC for use
with SDEC-4500. Retrofit kits are also available. Please contact JBL Synthesis Technical Support for more information
at 516.594.0300 (USA only).

The SDEC-4500 is capable of processing up to 12 inputs and up to 20 outputs. Depending on the type and number 
of outputs will determine which connections you should use to connect the SDEC to the rest of your system. Please
refer to the connection diagram for more information.

C

ONNECTION

N

OTES

• The SDEC-4500 can process two outputs for the front left, center and right channels to output to an amplifier 

for a bi-amplified system. There are discrete outputs for a single high-frequency horn speaker (SAM1HF) and 
low-frequency (SAM2LF) speakers. These outputs can only be used with speakers designed to be used with 
an external crossover. Do not use the SDEC Digital Equalizer for any speakers other than the recommended 
Synthesis speaker packages. 

• There are three pairs of outputs for side speakers. If you are only using one pair of side speakers, then you may

leave the second or third pair of outputs with no connection. If you are using a second or third pair of side speakers,
then you should connect the pair closest to the front speakers to Output 1, the pair in the middle of the room to
Output 2, and the pair closest to the rear speakers to Output 3.

• There are up to four subwoofer outputs. You should use them in pairs so that you either have two or four 

subwoofers. All Synthesis systems are designed for at least two subwoofers. 

• You 

must

connect the SDEC-4500P and the SDEC-4500X using the BlueLink connection, using an Ethernet 

network 

patch

cable, Cat. 5e minimum.

• The two units must be connected to an Ethernet network hub for the final calibration process. Both units need 

to be connected to the same hub or router, and an open port needs to be accessible for the calibration computer. 

• When using the SDP-40HD processor, make sure the subwoofer (in speaker setup) is set to Mono output and con-

nect to the Subwoofer Left output.

S

ELECTING

F

ULL

-R

ANGE OR

B

I

-A

MPED

C

ONFIGURATION

There are two ways to select between bi-amped or full-range LCR operation.

Please note: Only Method One can be done on the control ports (without a computer). Method Two requires a computer running 
the appropriate configuration software. Please contact JBL Synthesis Technical Support for more information.

M

ETHOD

O

NE

: W

ITHOUT A

C

OMPUTER

Full Range:

With the SDEC powered up and running, 

Bi-Amped: 

With the SDEC powered up and running, 

connect Control Input 1 to “C” (common) on the back of 

connect Control Input 2 to “C” for bi-amped. This is 

the unit for full range. This 

a temporary connection

is a temporary contact and 

and should not be

should not be left in place.

left in place.

M

ETHOD

T

WO

: W

ITH A

C

OMPUTER

While online and in Operate mode from within London Architect

or when using the Java remote, select the appropriate

speaker configuration as your installation requires. The software will automatically configure the outputs correctly.

I

NPUT

/O

UTPUT

A

SSIGNMENTS

SDEC3000.4500.om.qxd  4/16/09  10:06 AM  Page 8

Get user manuals: 

See SafeManuals.com

 

 

Summary of Contents for JBL SYNTHESIS SDEC-3000

Page 1: ...SYNTHESIS SDEC 3000 SDEC 4500 DIGITAL EQUALIZER INSTALLER S MANUAL SDEC3000 4500 om qxd 4 16 09 10 06 AM Page 1 Get user manuals See SafeManuals com...

Page 2: ...ULL RANGE FRONT SPEAKERS 10 CONNECTION TO THE REST OF THE JBL SYNTHESIS SYSTEM 11 SDEC 3000 11 SYNTHESIS TWO ARRAY 11 SYNTHESIS THREE ARRAY 11 SYNTHESIS FOUR 11 SYNTHESIS PROJECT ARRAY 11 SDEC 4500 12...

Page 3: ...provide some protection against voltage surges and built up static charges Article 810 of the National Electrical Code ANSI NFPA 70 provides information with regard to proper grounding of the mast and...

Page 4: ...like nearly all other audio components on the market the SDEC has been designed to work specifically with other Synthesis system components This narrow application focus has allowed JBL engineers to d...

Page 5: ...ntly for future use and is not supported SDEC 4500 does not include USB 2 DATA ACTIVITY The data activity LED will flash to indicate that the device is communicating with another control device either...

Page 6: ...k connection using a Cat 5e patch cable C CONTROL INPUTS The SDEC 4500 can be configured for full range or bi amp operation by using these control inputs The SDEC 3000 does not need or use this connec...

Page 7: ...rt on the rear panel of the unit for the final calibration process You can connect the SDEC 3000 through any standard Ethernet hub When using the SDP 40HD processor make sure the subwoofer in speaker...

Page 8: ...kers to Output 1 the pair in the middle of the room to Output 2 and the pair closest to the rear speakers to Output 3 There are up to four subwoofer outputs You should use them in pairs so that you ei...

Page 9: ...RIGHT SIDE 3 C4 S7165 2 CH6 21 LEFT REAR D1 S7165 1 CH7 22 RIGHT REAR D2 S7165 2 CH7 AUX L D3 AUX R D4 S Su ur rr ro ou un nd d P Pr ro oc ce es ss so or r tto o S SD DE EC C 4 45 50 00 0P P IIn np pu...

Page 10: ...20 1 CH1 bridged 10 N C A2 11 RIGHT FRONT A3 S820 2 CH1 bridged 12 N C A4 13 CENTER FRONT B1 S820 3 CH1 bridged 14 N C B2 15 LEFT SIDE 1 B3 S7165 1 CH1 16 RIGHT SIDE 1 B4 S7165 1 CH2 17 LEFT SIDE 2 C1...

Page 11: ...0 S PDIF INPUTS IR IN TRIGGER OUTPUTS OUT S PDIF S N RS 232 2 1 VIDEO S VIDEO AUDIO INPUTS L R C SUB LS RS L R L R C SUB LS RS Y PR PB Y PR PB Y PR PB INPUT 1 INPUT 3 INPUT 2 Y PR PB OUTPUT 1 2 3 4 1...

Page 12: ...EGLAGE CORRECT PUSH 3 2 1 PUSH 3 2 1 PUSH 3 2 1 PUSH 3 2 1 PUSH 3 2 1 PUSH 3 2 1 PUSH 3 2 1 FUSE FUSE 120V 60Hz 1200W T8AL 250V 8A SLO BLO T8AL 250V 8A SLO BLO 7165 6 7 6 7 TRIGGER IN 3 24 VDC OUT CHA...

Page 13: ...50V 6 3A SLO BLO T6 3AL 250V 6 3A SLO BLO 120V 60Hz 800W PUSH 3 2 1 PUSH 3 2 1 FUSE FUSE 820 TRIGGER BRIDGED BRIDGED MINIMUM IMPEDANCE 4 OHMS STEREO MINIMUM IMPEDANCE 8 OHMS BRIDGED MONO ATTENTION VOI...

Page 14: ...ED MINIMUM IMPEDANCE 4 OHMS STEREO MINIMUM IMPEDANCE 8 OHMS BRIDGED MONO ATTENTION VOIR LE CAHIER D INSTRUCTION MODE BRIDGED MONO STEREO IN 3 24 VDC OUT CHASSIS GROUND T6 3AL 250V 6 3A SLO BLO T6 3AL...

Page 15: ...DEVICE AND ETHERNET SWITCH PANEL LED INDICATORS SIGNAL PRESENT PER INPUT CLIP PER INPUT SYNC 48V PER INPUT LCD CONDUCTOR ACTIVE NET LINK ACTIVE DATA ACTIVITY MAINS VOLTAGE 85 270V AC 50 60HZ POWER CON...

Page 16: ...of Conformity We Harman Consumer Group Inc 2 route de Tours 72500 Ch teau du Loir France declare in own responsibility that the products described in this owner s manual are in compliance with technic...

Reviews: