background image

6

7

9

8

A

B

C

D

SDEC-3000

SDEC-4500P and
SDEC-4500X

BlueLink

7

AC M

AINS

AC Mains input to the universal switched-mode power supply; operates over a wide range of AC input voltages 
from 85V to 270V, 50/60Hz.

8

L

OCATE

Pressing the Locate switch on the rear of the unit will illuminate the Locate switch on the front and identify the
device within the DACS software.

9

RS-232

Serial port for connection of external calibration and configuration equipment not used at this time.

A

E

THERNET

The main connection for the proprietary system control network, and for third-party Ethernet control. The SDEC
must be connected to an Ethernet hub during the calibration process. 

B

B

LUE

L

INK

C

ONNECTORS

(SDEC-4500 O

NLY

)

The SDEC-4500P and SDEC-4500X use BlueLink to send and receive audio data. 

Please Note: When using the SDEC-4500, you must connect the two units through the BlueLink connection, using 
a Cat. 5e patch cable.

C

C

ONTROL

I

NPUTS

The SDEC-4500 can be configured for full-range or bi-amp operation by using these control inputs. The SDEC-3000
does not need or use this connection.

D

I

NPUT

/O

UTPUT

C

ARD

P

OSITIONS

A, B, C 

AND

D

These connectors provide the balanced and unbalanced connections for the input/output card fitted in the four card
slots in a JBL Synthesis SDEC device. A green LED next to the slot assignment letter A, B, C or D indicates that an
input card is fitted and an amber LED when an output card is fitted. The analog connections are balanced/unbalanced,
on Phoenix/Combicon connectors. Depending on which model and configuration you have purchased will determine
which input/output card has been installed at the factory. Please make sure to order the correct wiring kit, either
S3000IC or S4500IC, with your system.

D

ETAILED

D

IAGRAM

– R

EAR

P

ANEL

SDEC-3000 has no BlueLink

connections, but is otherwise identical to the SDEC-4500P and SDEC-4500X.

SDEC3000.4500.om.qxd  4/16/09  10:06 AM  Page 6

Get user manuals: 

See SafeManuals.com

 

 

Summary of Contents for JBL SYNTHESIS SDEC-3000

Page 1: ...SYNTHESIS SDEC 3000 SDEC 4500 DIGITAL EQUALIZER INSTALLER S MANUAL SDEC3000 4500 om qxd 4 16 09 10 06 AM Page 1 Get user manuals See SafeManuals com...

Page 2: ...ULL RANGE FRONT SPEAKERS 10 CONNECTION TO THE REST OF THE JBL SYNTHESIS SYSTEM 11 SDEC 3000 11 SYNTHESIS TWO ARRAY 11 SYNTHESIS THREE ARRAY 11 SYNTHESIS FOUR 11 SYNTHESIS PROJECT ARRAY 11 SDEC 4500 12...

Page 3: ...provide some protection against voltage surges and built up static charges Article 810 of the National Electrical Code ANSI NFPA 70 provides information with regard to proper grounding of the mast and...

Page 4: ...like nearly all other audio components on the market the SDEC has been designed to work specifically with other Synthesis system components This narrow application focus has allowed JBL engineers to d...

Page 5: ...ntly for future use and is not supported SDEC 4500 does not include USB 2 DATA ACTIVITY The data activity LED will flash to indicate that the device is communicating with another control device either...

Page 6: ...k connection using a Cat 5e patch cable C CONTROL INPUTS The SDEC 4500 can be configured for full range or bi amp operation by using these control inputs The SDEC 3000 does not need or use this connec...

Page 7: ...rt on the rear panel of the unit for the final calibration process You can connect the SDEC 3000 through any standard Ethernet hub When using the SDP 40HD processor make sure the subwoofer in speaker...

Page 8: ...kers to Output 1 the pair in the middle of the room to Output 2 and the pair closest to the rear speakers to Output 3 There are up to four subwoofer outputs You should use them in pairs so that you ei...

Page 9: ...RIGHT SIDE 3 C4 S7165 2 CH6 21 LEFT REAR D1 S7165 1 CH7 22 RIGHT REAR D2 S7165 2 CH7 AUX L D3 AUX R D4 S Su ur rr ro ou un nd d P Pr ro oc ce es ss so or r tto o S SD DE EC C 4 45 50 00 0P P IIn np pu...

Page 10: ...20 1 CH1 bridged 10 N C A2 11 RIGHT FRONT A3 S820 2 CH1 bridged 12 N C A4 13 CENTER FRONT B1 S820 3 CH1 bridged 14 N C B2 15 LEFT SIDE 1 B3 S7165 1 CH1 16 RIGHT SIDE 1 B4 S7165 1 CH2 17 LEFT SIDE 2 C1...

Page 11: ...0 S PDIF INPUTS IR IN TRIGGER OUTPUTS OUT S PDIF S N RS 232 2 1 VIDEO S VIDEO AUDIO INPUTS L R C SUB LS RS L R L R C SUB LS RS Y PR PB Y PR PB Y PR PB INPUT 1 INPUT 3 INPUT 2 Y PR PB OUTPUT 1 2 3 4 1...

Page 12: ...EGLAGE CORRECT PUSH 3 2 1 PUSH 3 2 1 PUSH 3 2 1 PUSH 3 2 1 PUSH 3 2 1 PUSH 3 2 1 PUSH 3 2 1 FUSE FUSE 120V 60Hz 1200W T8AL 250V 8A SLO BLO T8AL 250V 8A SLO BLO 7165 6 7 6 7 TRIGGER IN 3 24 VDC OUT CHA...

Page 13: ...50V 6 3A SLO BLO T6 3AL 250V 6 3A SLO BLO 120V 60Hz 800W PUSH 3 2 1 PUSH 3 2 1 FUSE FUSE 820 TRIGGER BRIDGED BRIDGED MINIMUM IMPEDANCE 4 OHMS STEREO MINIMUM IMPEDANCE 8 OHMS BRIDGED MONO ATTENTION VOI...

Page 14: ...ED MINIMUM IMPEDANCE 4 OHMS STEREO MINIMUM IMPEDANCE 8 OHMS BRIDGED MONO ATTENTION VOIR LE CAHIER D INSTRUCTION MODE BRIDGED MONO STEREO IN 3 24 VDC OUT CHASSIS GROUND T6 3AL 250V 6 3A SLO BLO T6 3AL...

Page 15: ...DEVICE AND ETHERNET SWITCH PANEL LED INDICATORS SIGNAL PRESENT PER INPUT CLIP PER INPUT SYNC 48V PER INPUT LCD CONDUCTOR ACTIVE NET LINK ACTIVE DATA ACTIVITY MAINS VOLTAGE 85 270V AC 50 60HZ POWER CON...

Page 16: ...of Conformity We Harman Consumer Group Inc 2 route de Tours 72500 Ch teau du Loir France declare in own responsibility that the products described in this owner s manual are in compliance with technic...