6
7
9
8
A
B
C
D
SDEC-3000
SDEC-4500P and
SDEC-4500X
BlueLink
7
AC M
AINS
AC Mains input to the universal switched-mode power supply; operates over a wide range of AC input voltages
from 85V to 270V, 50/60Hz.
8
L
OCATE
Pressing the Locate switch on the rear of the unit will illuminate the Locate switch on the front and identify the
device within the DACS software.
9
RS-232
Serial port for connection of external calibration and configuration equipment not used at this time.
A
E
THERNET
The main connection for the proprietary system control network, and for third-party Ethernet control. The SDEC
must be connected to an Ethernet hub during the calibration process.
B
B
LUE
L
INK
™
C
ONNECTORS
(SDEC-4500 O
NLY
)
The SDEC-4500P and SDEC-4500X use BlueLink to send and receive audio data.
Please Note: When using the SDEC-4500, you must connect the two units through the BlueLink connection, using
a Cat. 5e patch cable.
C
C
ONTROL
I
NPUTS
The SDEC-4500 can be configured for full-range or bi-amp operation by using these control inputs. The SDEC-3000
does not need or use this connection.
D
I
NPUT
/O
UTPUT
C
ARD
P
OSITIONS
A, B, C
AND
D
These connectors provide the balanced and unbalanced connections for the input/output card fitted in the four card
slots in a JBL Synthesis SDEC device. A green LED next to the slot assignment letter A, B, C or D indicates that an
input card is fitted and an amber LED when an output card is fitted. The analog connections are balanced/unbalanced,
on Phoenix/Combicon connectors. Depending on which model and configuration you have purchased will determine
which input/output card has been installed at the factory. Please make sure to order the correct wiring kit, either
S3000IC or S4500IC, with your system.
D
ETAILED
D
IAGRAM
– R
EAR
P
ANEL
SDEC-3000 has no BlueLink
™
connections, but is otherwise identical to the SDEC-4500P and SDEC-4500X.
SDEC3000.4500.om.qxd 4/16/09 10:06 AM Page 6