background image

Right Main Output

PRX635

PRX612M

Monitor Output

Live Performance Or Music Playback Reinforcement System With Stage Monitors 
(PRX635 and PRX612M or PRX615M) 

This is an ideal system when wide coverage and good directivity is required, specifically in highly reverberant
rooms. The horn loaded PRX635 3-way system will control the propagation of the sound much better than a
conventional 2-way system. The more directional or controlled the sound is the more independent the system
becomes from the room acoustics present, resulting in a much clearer sound. The PRX635’s full low end is an
additional advantage when no subs are used. The PRX612Ms are set to the “monitor” EQ setting. 

27

PRX600.UsersGuide.020411.qxd  2/4/11  11:13 AM  Page 27

Summary of Contents for JBL Professional PRX600 Series

Page 1: ...P R X 6 1 2 M P R X 6 1 5 M P R X 6 2 5 P R X 6 3 5 P R X 6 1 8 S P R X 6 1 8 S X L F U s e r s G u i d e PRX600 UsersGuide 020411 qxd 2 4 11 11 13 AM Page 1...

Page 2: ...2 PRX600 UsersGuide 020411 qxd 2 4 11 11 13 AM Page 2...

Page 3: ...e PRX600 Series Power Amplifier 10 Introduction To The PRX600 Series 11 12 System Specifications 13 18 System Setup 19 22 Setting Input Sensitivity 23 Setting The Gain 24 Application Examples 25 28 Re...

Page 4: ...been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not opera...

Page 5: ...as a sail and topple the system Unless you are confident that you can handle the weight of the speaker ask another person to help you get it onto the tripod stand or pole The PRX635 should be pole mo...

Page 6: ...should be provided to the Professional Engineer for design purposes Uniform Building Code as applicable Municipal Building Code as applicable and Seismic Code as applicable The installation of the ha...

Page 7: ...x 35 mm forged shoulder steel eyebolts with washers WARNING Suspension of JBL loudspeakers must employ a minimum of two attachment points When bridling a JBL loudspeaker system two legs of equal leng...

Page 8: ...quilateral triangle is intended to alert the user to the presence of uninsulated Dangerous Voltage within the products enclosure that may be of sufficient magnitude to consitute a risk of electric sho...

Page 9: ...nly CSA Certified to operate only at 120V in Canada FCC Compliance Notice This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not...

Page 10: ...ratures and the heat sink on the rear of the enclosure is in direct sunlight Always ensure adequate cooling and appropriate shade AC Power Requirements Standard PRX600 series speaker systems are equip...

Page 11: ...he PRX Series integrate seamlessly with one another offering a multitude of choices when tailoring a system to fit your specific needs Whether you need a single speaker on a stand for public address s...

Page 12: ...ing when you re confronted with a barrage of specifications from manufacturers all claiming to have the best performance A self powered speaker is really a system unto itself it s a closed system Unli...

Page 13: ...ter slope High Low Pass HF 36 dB Oct High Pass Crossover Frequency 2 kHz Amplifier Design Crown Class D Power Rating 1000 W 2 x 500 Speaker LF Driver 1 x JBL 262F 1 380 mm 12 in Differential Drive dua...

Page 14: ...HF 36dB Oct High Pass Crossover Frequency 1 8 kHz Amplifier Design Crown Class D Power Rating 1000 W 2 x 500 Speaker LF Driver 1 x JBL 265F 1 380 mm 15 in Differential Drive dual voice coil and magnet...

Page 15: ...n Class D Power Rating 1500 W 3 x 500 Speaker LF Driver 2 x JBL 265F 1 380 mm 15 in Differential Drive dual voice coil and magnetic gap neodymium woofer HF Driver 1 x JBL 2408H 1 37 5 mm 1 5 in annula...

Page 16: ...eaker LF Driver 1 x JBL 265F 1 380 mm 15 in Differential Drive dual voice coil and magnetic gap neodymium woofer MF Driver 1 x JBL 195H 165 mm 6 5 in horn loaded midrange transducer HF Driver 1 x JBL...

Page 17: ...lter slope Crossover Frequency 120 Hz Amplifier Design Crown Class D System Power Rating 600 W Speaker LF Driver 268G 460 mm 18 in Differential Drive dual voice coil and magnetic gap neodymium woofer...

Page 18: ...ency 90 Hz Dynamic Control Input dbx Type IV limiter circuit Amplifier Design Crown Class D Power Rating 1000 W 2 x 500 Speaker LF Driver 460 mm 18 in Differential Drive dual voice coil and magnetic g...

Page 19: ...ll provide greater accuracy of reproduced music higher speech intelligibility and maximum overall level BOOST is particularly useful at lower levels to enhance the low and high frequencies of pre reco...

Page 20: ...ser selection of different country voltage ratings 8 AC LINE INPUT Standard IEC AC line input connector Real Panel Indicators 4 SIGNAL Signal indicator The green LED illuminates when a signal is prese...

Page 21: ...e illumination of the grille logo 7 LINE SELECT Allows user selection of different local voltage ratings 8 AC LINE INPUT Standard IEC AC line input connector Indicators 4 SIGNAL Signal indicator The g...

Page 22: ...ng distortion and may lead to premature failure of your speaker system If the LIMIT LED illuminates excessively Reduce the LEVEL control Reduce the output level of the mixer or other source connected...

Page 23: ...indicated by the 4 dB region The LEVEL control can then be trimmed to optimize the performance of the system see Setting The Gain When a microphone instrument or other consumer product is connected to...

Page 24: ...set to just before clip or when the input LED just starts to flicker 2 Position the channel fader for that input to 0 dB 3 Position the Master output fader to 0 dB 4 With the Mic Line button set to L...

Page 25: ...ources without the need for extra mixer or pre amplifier The XLR or 1 4 inch input jack provides versatility and cabling options and the mic line input sensitivity selector switch optimizes the speake...

Page 26: ...lite system PRX612M is a perfect match to the subwoofer From the master outputs of your mixer route the wires to the subwoofer first and select the x over in high pass option Route the cable from the...

Page 27: ...t rooms The horn loaded PRX635 3 way system will control the propagation of the sound much better than a conventional 2 way system The more directional or controlled the sound is the more independent...

Page 28: ...doors a flexible system like this will deliver excellent results The dual 15 inch PRX625 delivers mighty bottom end and crisp highs The combination of extra PRX618S XLF subwoofers gives it an even mor...

Page 29: ...into the cable is cancelled out by the opposite signals at the receiving end Balanced connections are preferred for long cable runs Unbalanced Lines Unbalanced cable is a two wire system where the shi...

Page 30: ...ts TS unbalanced 1 4 inch phone jack to XLR M This cable is electrically identical to TRS unbalanced 1 4 inch phone and maybe used interchangeably XLR M to RCA phono cable Connects consumer audio prod...

Page 31: ...signal Faulty cables and connections Disconnect and re seat signal cables Replace suspected cable with a known good cable No sound with microphone connected directly to the MIC input Microphone requir...

Page 32: ...ur PRX speakers Use a DI direct injection box to convert your unbalanced equipment output to a balanced output Improper system gain structure Review the Owner s Manual for your system setup and adjust...

Page 33: ...33 PRX600 UsersGuide 020411 qxd 2 4 11 11 13 AM Page 33...

Page 34: ...a charge will be made if replacement cartons are requested Payment of shipping charges is discussed in the next section of this warranty How To Obtain Warranty Performance If your JBL product ever nee...

Page 35: ...PRX600 UsersGuide 020411 qxd 2 4 11 11 13 AM Page 35...

Page 36: ...PRX600 UsersGuide 020411 qxd 2 4 11 11 13 AM Page 36...

Reviews: