This setting will produce medium heat with the Dis
-
tribution Blower on "low".
This setting will produce a room temperature of 70 de
-
grees with the Distribution Blower at "medium" speed.
This setting will produce continuous maximum heat output
with the Distribution Blower at full speed.
Fig. 16
When to use "Stove Temp Mode"
In "Stove Temp Mode" the Temp Dial deter-
mines the temperature of the stove. Heat output and
fuel consumption will remain constant. This makes
it possible to tell how long a hopper full of coal will
last. The distribution blower speed will vary according
to the position of the mode selector, between "low"
and "high", fig. 16.
When to use "Room Temp Mode"
In "Room Temp Mode" heat output is controlled
automatically by use of the Room Sensing Probe.
When the Room Sensing Probe calls for heat, the
stove will increase output. When the Room Sens-
ing Probe is getting close to the set temperature,
the stove will begin to level off output and keep the
fire burning at just the right temperature to maintain
that setting. If the temperature in the room exceeds
the set point, the stove will idle on a low burn until
more heat is needed.
High output is determined by the Feed Rate.
The maximum Feed Rate should be set for 1
1
/
2
" to
2" of ash in front of the fire.
In "Room Temp Mode" fuel consumption is
sacrificed for exact room temperature. Therefore,
as it gets colder, more coal will be burned automati-
cally.
The distribution blower speed will vary accord-
ing to the position of the mode selector.
Operation
Keep coal off
ledges
Fig 17
Summary of Contents for DVC-500
Page 2: ...This appliance is also approved for installation into a shop...
Page 10: ...10 Installation...
Page 12: ...12 Installation...
Page 13: ...13 Installation...
Page 16: ...16 ESP Control Hopper Lid Latch Ash Door Latch Handle Glass Door Latch Handle Side Panel Latch...
Page 26: ...26 Wiring Diagram...
Page 32: ...32...
Page 33: ...33...
Page 34: ...34 Service Maintenance Log Date Of Service Performed By Description Of Service...
Page 35: ...35 Service Maintenance Log Date Of Service Performed By Description Of Service...
Page 36: ......