page 57
DriveCore Install DA Series Operation Manual
AC Power Draw and Thermal Dissipation
AC Power Draw and Thermal Dissipation:
Pink noise 12 dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Data based on all channels driven.
DCi 4|600DA – Bridge Mode
120VAC / 60Hz
230VAC / 50Hz
Condition
Load
Line
current
(amps)
Power Dissipated as Heat
Line
current
(amps)
Power Dissipated as Heat
watts
BTU
kcal/hr
watts
BTU
kcal/hr
At Idle Awake
N/A
1.0
113
387
98
0.6
118
404
102
1/8 Power
Pink Noise
Typical of program
material just at clip
4Ω
2.7
170
582
147
1.4
165
563
142
8Ω
4.1
176
599
151
2.1
178
608
153
16Ω
3.8
156
531
134
2.0
151
516
130
140V
(16Ω)
3.9
156
534
135
2.1
158
538
136
200V
(33.33Ω)
3.8
150
511
129
2.0
141
482
122
1/3 Power
Pink Noise
Typical of program
material at
extreme clip
4Ω
5.6
247
844
213
2.9
235
801
202
8Ω
9.5
298
1018
257
4.8
269
916
231
16Ω
8.7
223
760
192
4.5
207
705
178
140V
(16Ω)
8.7
230
786
198
4.5
214
730
184
200V
(33.33Ω)
8.7
203
692
174
4.4
176
601
151
DCi 4
|
600DA – Dual Mode
120VAC / 60Hz
230VAC / 50Hz
Condition
Load
Line
current
(amps)
Power Dissipated as Heat
Line
current
(amps)
Power Dissipated as Heat
watts
BTU
kcal/hr
watts
BTU
kcal/hr
At Idle Awake
N/A
1.0
113
386
97
0.6
115
391
99
1/8 Power
Pink Noise
Typical of program
material just at clip
2Ω
2.8
172
588
148
1.5
162
555
140
4Ω
4.1
165
564
142
2.1
171
582
147
8Ω
3.9
151
514
130
2.0
138
470
119
70V
(16.33Ω)
3.9
147
500
126
2.1
143
488
123
100V
(33.33Ω)
3.7
138
470
118
2.0
134
458
115
1/3 Power
Pink Noise
Typical of program
material at
extreme clip
2Ω
5.9
256
874
220
3.1
253
862
217
4Ω
9.0
264
900
227
4.5
234
799
201
8Ω
8.6
213
726
183
4.5
206
704
178
70V
(16.33Ω)
8.8
223
760
192
4.5
200
682
172
100V
(33.33Ω)
8.5
196
670
169
4.4
190
648
163