page 43
DriveCore Install DA Series Operation Manual
Using the GPIO Port
Using the GPIO Port
DCi DA Series amplifiers come with a 2-in/2-out General Purpose In/Out (GPIO) Control port in the form of a 6-position RJ-11 connector. The Control port has multiple
functions and uses, which include preset selection and gain control, among others.
AUX
CLASS 2
WIRING
INPUT
GPIO
ETHERNET
100Mb
ACT
DANTE
OUT
+3.3V
IN
PRIMARY
SECONDARY
CAUTION - TO REDUCE THE RISK OF ELECTRIC
SHOCK, GROUNDING OF THE CENTER PIN
OF THIS PLUG MUST BE MAINTAINED
4
3
2
1
8
7
6
5
MAC
ADDRESS
SERIAL NUMBER
SERIAL NUMBER
BAR CODE
RESET
DATA
PRESET
AUX
CLASS 2
WIRING
INPUT
GPIO
ETHERNET
100Mb
ACT
DANTE
OUT
+3.3V
IN
PRIMARY
SECONDARY
CAUTION - TO REDUCE THE RISK OF ELECTRIC
SHOCK, GROUNDING OF THE CENTER PIN
OF THIS PLUG MUST BE MAINTAINED
4
3
2
1
8
7
6
5
MAC
ADDRESS
SERIAL NUMBER
SERIAL NUMBER
BAR CODE
RESET
DATA
PRESET
Figure 50:
The GPIO port
Hardware Specification
Inputs are capable of either binary or analog control of a state variable (SV) within the amplifier. Outputs are binary only and represent an SV of the amplifier. Additionally,
outputs can be controlled independently via the software.
Control port pinout descriptions:
PIN 1:
Output 1. 0VDC to +3.3VDC output. Output impedance = 1KΩ pullup to +3.3V.
PIN 2:
Output 2. 0VDC to +3.3VDC output. Output impedance = 1KΩ pullup to +3.3V.
PIN 3:
Input 1. 0VDC to +3.3VDC input. Logic = TTL thresholds. Analog = full scale 0–3.3V. Input impedance > 20KΩ.
PIN 4:
+3.3VDC output. LIMIT = 30mA. Output impedance = 100Ω to +3.3V.
PIN 5:
Input 2. 0VDC to +3.3VDC input. Logic = TTL thresholds. Analog = full scale 0–3.3V. Input impedance > 20KΩ.
PIN 6:
GND.
Configuring the Control Port Inputs
To access Control port configuration, double-left-click on the
DCi DA Amp
icon in the Room window to highlight it. Now, right-click the
DCi DA Amp
icon, and then
select
Configure Control Ports
). The Control Ports tab will open (see
).
Key Control port input configuration points:
• Each of the two Control port inputs support variable
control (using a potentiometer), binary control (using a
switch), or multilevel control (using a rotary switch with
voltage dividers).
• Audio Architect is used to assign up to 40 SV's to each
control input.
Figure 51:
Accessing the Control Ports tab