page 15
DriveCore Install DA Series Operation Manual
Installing the Software and Configuring the Network
c� HiQnet Conflict
If a device has a unique IP address yet has a HiQnet address conflict, this error will be shown regardless of other status notifications. When the device is not
selected, the "HiQnet conflict" label is represented in red.
The "HiQnet conflict" status is determined by the following conditions:
• The device is discoverable at the MAC address level.
• The device has a valid and unique IP address (manual or DHCP/Auto-IP).
• The device has a HiQnet address that conflicts with another device which has already been discovered by NetSetter.
d� Locked
If a device has a unique IP address and a unique HiQnet address, this condition will be shown if the device is access controlled. When the device is not selected,
the "Locked" label is represented in yellow.
The "Locked" status is determined by the following conditions:
• The device is discoverable at the MAC address level.
• The device has a valid and unique IP address (manual or DHCP/Auto-IP).
• The device has a unique HiQnet address.
• The device is access controlled.
When a device has been discovered in a Locked state and any field is attempted to be edited for the first time, a dialog prompting for the Admin password will
appear. Only a successful login with the Admin password will enable all fields to be edited. This state may need to be reset on rediscovery after applying current
edits, requiring the Admin password to be entered again.
e� Discovering
This condition will be displayed if the device has had changes made to its IP configuration or HiQnet address and HiQnet NetSetter is waiting to re-establish
connection. When a device being rediscovered is not selected, all fields within the device row are displayed but grayed out.
The "Discovering" status is determined by the following conditions:
• The device had been previously discovered at the MAC address level.
• Edits had been made to one or more fields.
• The device is being rediscovered after applying current edits.
NOTE:
Since the sort order automatically updates when a field within the sorted column is updated, the rediscovered device will occupy the same row on
rediscovery. The exception is when DHCP/Auto-IP or Random ID has been set prior to applying current edits, in which case the rediscovered device will occupy
the appropriate row in the current column sort order.
9� Device Type
The device class name is displayed here, as reported by the discovered device. To the left of each device class name, the brand icon is displayed. The software
application name is displayed for discovered PCs running an instance of HiQnet software. HiQnet software programs include System Architect, Audio Architect, and
Performance Manager.
NOTE:
The Device Type field may not be edited inline.
NOTE:
Devices are not discoverable at the IP or HiQnet level. A device which is not discoverable at the IP level (invalid IP address, etc.) or HiQnet address level
(HiQnet address conflict, etc.) will not be able to report its class name. In this instance, the Device Type field will display a "?" to indicate that the field may exist but
that the software does not have enough discoverability of the device to determine the value. A blank field or "-" implies the value is null.
10� Device Name
The user-definable Device Name is displayed here, as reported by the discovered device.
NOTE:
This field may be edited inline if you want to change the Device Name. This field may not be edited for discovered PCs running an instance of HiQnet
software.
NOTE:
Devices are not discoverable at the IP or HiQnet level.
A device which is not discoverable at the IP level (invalid IP address, etc.) or HiQnet address level
(HiQnet address conflict, etc.) will not be able to report its Device Name. In this instance, the Device Name field will display a "?" to indicate that the field may exist but
that the software does not have enough discoverability of the device to determine the value. A blank field or "-" implies the value is null.
NOTE:
Once edits have been made, it is critical to click the
Apply Current Edits
or
Apply and Exit
buttons for the changes to take affect.