![Harman BSS Soundweb London BLU-103 Installation Manual Download Page 14](http://html1.mh-extra.com/html/harman/bss-soundweb-london-blu-103/bss-soundweb-london-blu-103_installation-manual_3952569014.webp)
8
OPTO (WATCHDOG) OUTPUT
Connectors:
Phoenix/Combicon connector for failsafe control
Opto Output current:
14mA maximum
Withstanding voltage:
80V maximum (Off)
Series Impedance:
220 Ohms (isolated)
CONTROL NETWORK
Connectors:
RJ45 Ethernet connector
Maximum cable length:
100m/300ft on Category 5 or better cable between device and Ethernet switch
Maximum number of nodes:
60
BLU link AUDIO NETWORK
Connectors:
2 x RJ45 Ethernet connectors
Maximum cable length:
100m/300ft on Category 5e or better cable between devices
Latency:
11/Fs [0�23ms@48k]
Pass-Through Latency:
4/Fs [0�08ms@48k]
POWER AND DIMENSIONS
Mains Voltage:
100-240V AC, 50/60Hz
Power Consumption:
<55VA
BTU Rating:
<188 BTU/hr
Operating Temperature Range:
5(41) to 35(95) degrees C(degrees F)
Dimensions (HxWxD):
1�75” (45mm)(1U) x 19” (483mm) x 12�5” (318mm)
Weight:
9�1 lbs / 4�1 kg
BSS Audio incorporates high quality mechanical fans in some products� All mechanical fans have a limited life expectancy� We
recommend annual inspection of fans for dust occlusion and excessive noise� Fan assemblies should be replaced after six to ten
years of use� Environmental factors such as elevated temperature, dust, and smoke can adversely affect fan life� Systems exposed to
these conditions should be inspected more frequently� Fan replacement can be performed either at the factory or by an experienced
technician in the field. Please contact BSS Technical Support for more information on purchasing replacement parts or product
service�
BSS Audio has a policy of continued product improvement and accordingly reserves the right to change features and specifications
without prior notice�