11
THD:
<0.01% [20Hz to 20kHz, +10dBu output]
Dynamic Range:
108dB typ. [22Hz to 22kHz unweighted]
Crosstalk:
<-75dB
D/A Latency:
28/Fs [0.58ms@48k, 0.29ms@96k]
DIGITAL OUTPUTS
Up to 16 AES/EBU or S/PDIF on Phoenix/Combicon removable screw connectors
Output Impedance:
110 ohm [AES/EBU], 75 ohm [S/PDIF]
Sample Rate:
48kHz or 96kHz
Sample Rate conversion:
8kHz-96kHz
THD+N:
<-140dB
Latency SRC OFF:
6/Fs [0.13ms@48k, 0.06ms@96k]
Latency SRC ON:
60/Fs [1.25ms@48k, 0.63ms@96k]
CONTROL PORTS
12 inputs and 6 outputs
Control Input Voltage:
0 to 4.5v
Control Input Impedance:
4.7kOhms to +5V [2-wire mode] >1MOhm [3-wire mode]
Logic Output Voltage:
0 or +5V unloaded
Logic Output Impedance:
440 Ohm
Logic Output Current:
10mA source, 60mA sink
WATCHDOG OUTPUT
Phoenix/Combicon connector for failsafe control
Opto Output current:
14mA maximum
Withstanding voltage:
80V maximum [Off]
Series Impedance:
220 Ohms [isolated]
CONTROL NETWORK [All Models]
Connectors:
RJ45 Ethernet connector
Maximum cable length:
100m/328ft on Category 5 cable between device and Ethernet switch
BLU-link
TM
AUDIO NETWORK [BLU-800, 320, 160, 120]
Connectors:
2 x RJ45 Ethernet connectors
Maximum cable length:
100m/328ft on Category 5e cable between devices
Latency:
11/Fs [0.23ms@48k, 0.11ms@96k]
Pass Through Latency:
4/Fs [0.08ms@48k, 0.04ms@96k]
CobraNet
TM
AUDIO NETWORK [BLU-80, 32, 800, 320]
Connectors:
2 x RJ45 connectors
Maximum cable length:
100m/328ft on Category 5 cable between device and Ethernet switch
Latency:
1.33ms-5.33ms
Dante
TM
AUDIO NETWORK [BLU-806, 326]
Connectors:
2 x RJ45 connectors
Maximum cable length:
100m/328ft on Category 5 (100Mbps) or Category 5e/Category 6 (Gigabit) cable
between
devices
Latency:
0.15ms-5.0ms
AVB AUDIO NETWORK [BLU-805, 325]
Connectors:
2 x RJ45 connectors
Maximum cable length:
100m/328ft on Category 5e cable between device and AVB compliant Ethernet switch
Sample Rate:
48kHz
Latency:
0.5ms-2.0ms
Compatible AVB Switches:
BSS Audio/NETGEAR GS724T Ethernet Switch
LABX Titanium 411 Ruggedized AVB Ethernet Bridge Switch
POWER/TEMPERATURE
Mains Voltage:
100-240V AC, 50/60Hz
Power Consumption:
<35VA [BLU-80, 32, 16]; <55VA [BLU-800, 805, 806, 320, 325, 326, 160, 120]
BTU Rating:
<120 BTU/hr [BLU-80, 32, 16]; <188 BTU/hr [BLU-800, 805, 806, 320, 325, 326, 160,
120]
Operating Temperature Range:
5[41] to 35[95] degrees C[degrees F]