Harman AMX MIO-R3 Instruction Manual Download Page 16

Programming The Mio R-3

16

 Mio Modero R-3 Remote - Instruction Manual

Send_Commands

When used with ZigBee communications and a NetLinx master, the Mio R-3 supports a small set of Send_Commands. The table 

below captures all Send_Commands supported by the Mio R3

Serial Commands (Cont.)

^UNI

Set Unicode text. For the ^UNI command (%UN and ^BMF command), the Unicode text is sent as ASCII-HEX nibbles. 
Syntax: 

SEND_COMMAND <DEV>,"'^UNI-<vt addr range>,<button states range>,<unicode text>'"

Variables: 
• variable text address range = 1.
• button states range = (0 = All states, for General buttons 1 = Off state and 2 = On state). 
• unicode text = Unicode HEX value. 
Example: To send the variable text 'A' in Unicode to all states of the variable text display, (for which the character code is 

0041 Hex), send the following command:

SEND_COMMAND Keypad,"'^UNI-1,0,0041'"

Note: Unicode is always represented in a HEX value.

ZAP! 

Erase Configuration Information in Flash Memory
Syntax:

ZAP! t

Variables:
• t = MENU or FONT or blank
Example:

ZAP!

Clears all configuration information and erases the font. The text displayed on the LCD for the six devices returns to 

default and all parameters that can be set in Setup Mode are reset to their default value.

ZAP! MENU

Sets the text displayed on the LCD for the six devices to the default values.

ZAP! FONT

Erases the font from the flash.

Note: These commands are intended for serial use only. These commands cannot be issued when the device’s Setup 

Page is open.

ZIGC

Sets the ZigBee Channel
Syntax:

ZIGC <channel> (Decimal)

Example:

ZIGC 26

ZIGP

Sets the ZigBee Extended PAN ID
Syntax:

ZIGP <panId> (Decimal)

Example:

ZIGP 123A

Send_Commands

@BRT

Set Brightness level - This command can be used to customize the brightness of the red LEDs that backlight the power 

button if the predefined brightnesses in Setup Mode are not fine enough.
Syntax:

@BRT- <awake brightness level>, <sleep brightness level>

Variables:
• #  =  a  value  from  0  -  32.

@BRT- #       (Set LED Awake brightness level)

@BRT- #, #    (Set LED Awake brightness level, sleep brightness level)

Example:

@BRT-16

Sets the awake brightness level to 50%.

@BRT-32,5

Sets the awake brightness level to 100% and sleep brightness level to approximately 15%

^CFG

Enable or Disable Debug Mode
Syntax:

^CFG- <command value>

Variables:
• # = (1 = Debug Mode ON, 0 = Debug Mode OFF).
Example:

^CFG-1

Turn Debug Mode ON

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for AMX MIO-R3

Page 1: ...INSTRUCTION MANUAL MIO R3 MIO MODERO R 3 REMOTE KIT MIO R3 MIO R3 CC All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...they exit from the apparatus 11 ONLY USE attachments accessories specified by the manufacturer 12 USE ONLY with a cart stand tripod bracket or table specified by the manufacturer or sold with the appa...

Page 3: ...e 9 Debug Mode 9 Roaming Diagnostic Mode 9 Firmware Version 10 Device ID 10 LED Awake Brightness 10 LED Sleep Mode Brightness 10 ZigBee Extended PAN ID Channel and System Connection 10 Network Scan 10...

Page 4: ...16 UNI 16 ZAP 16 ZIGC 16 ZIGP 16 FML 17 FML S D L 17 GLY 17 JST 18 NUMD 18 REBOOT 18 SETD 18 SHO 18 SLEEP 18 SSL 18 SST 19 SWK 19 TXT 19 UNI 19 WAKE 19 ZIGC 19 ZIGP 19 Mio Remote Charging Base 20 Over...

Page 5: ...and certified as a stand alone device according to FCC Rules CFR 47 Part 15 Subpart C Contains FCC ID CWU NXR MO This device complies with Part 15 of the FCC rules Subject to the following two condit...

Page 6: ...battery connector fully within its port Mio R 3 FG148 03 Specifications Transmission Frequencies Zigbee RF wireless network IR 38 Khz IR 455 Khz Transmission Range ZigBee 100 feet 30 48m IR 38 Khz 100...

Page 7: ...R 3 into the Mio Remote Charging Base see the Mio Remote Charging Base section on page 20 Installing Custom Buttons 1 Flip and turn the device so that the buttons are facing away from you and the devi...

Page 8: ...back down on the PCB and return the unit over exposing the 6 screw points 9 Tighten the 6 screw points 10 Replace the battery door and slide the door upwards to lock it in place Patents This product i...

Page 9: ...font file to the Mio R 3 remote using the remote s program port see Using the Programming Jack on The Mio R 3 section on page 11 for details the remote must first be placed into Download mode Press 3...

Page 10: ...again toggles to the new mode 30 seconds after selecting the mode the menu returns to Setup mode ZigBee Extended PAN ID Channel and System Connection Pressing the 9 button will display the current Zi...

Page 11: ...to the port on the back of your computer 7 Configure the communication parameters in KeypadBuilder Updating Mio R 3 Firmware Updating firmware in the Mio R 3 is also done through the programming jack...

Page 12: ...126 166 206 S REV u 7 47 87 127 167 207 REC p 8 48 88 128 168 208 Power Symbol 9 49 89 129 169 209 0 10 50 90 130 170 210 1 11 51 91 131 171 211 2 12 52 92 132 172 212 3 13 53 93 133 173 213 4 14 54 9...

Page 13: ...xample SEND_COMMAND Panel FML 1 S Sets dynamic line to a menu line FML D Sets a line of the display to a dynamic line with no level Syntax FML variable text address range D Variables variable text add...

Page 14: ...ined address range Syntax JST variable text address range new text alignment Variable variable text address range 1 the address range corresponds to the dynamic line number only one line is supported...

Page 15: ...s new text 1 20 ASCII characters Default string is SLEEP Example SEND_COMMAND Panel SSL KeyPad Sleep Sends the string KeyPad Sleep to the master at time of sleep SST Sends a string to the master upon...

Page 16: ...the six devices returns to default and all parameters that can be set in Setup Mode are reset to their default value ZAP MENU Sets the text displayed on the LCD for the six devices to the default valu...

Page 17: ...set the Text Field on the R3 to dynamic FML D L Sets a line of the display to a dynamic line with a level Syntax FML variable text address range D L Variables variable text address range 1 the addres...

Page 18: ...ntax SETD deviceNum Example SETD 10020 SHO Show or hide text with a set variable text range Syntax SHO variable text address range command value Variables variable text address range 1 the address ran...

Page 19: ...tate new text 1 50 ASCII characters Example SEND_COMMAND Keypad TXT 1 Test Only Sends text to variable text line on display Note You must send an FML command before sending variable text to an R3 remo...

Page 20: ...Overview The Mio remotes are complemented with a Mio RCC charging base FG147 02 FIG 5 Mio RCC Charging Base FIG 6 Mio Remote Charging Base Top and Bottom view Insert MIO R3 front Charging contacts To...

Page 21: ...ote blinks red to indicate it is charging and illuminates solid red when it is done Full charge cycle for a depleted battery is approximately 3 hours Mio RCC FG147 03K with Base FG147 02 Specification...

Page 22: ...ility for errors or omissions AMX also reserves the right to alter specifications without prior notice at any time The AMX Warranty and Return Policy and related documents can be viewed downloaded at...

Reviews: