background image

Harman®  •  Accentra52i-TC Owner’s Manual_R3  •  2017 -___  •  09/17

11

3-90-00584c

Maintenance & Service 

When properly maintained, your stove will give you many 

years of trouble-free service. 

Contact your dealer

 to answer 

questions regarding proper operation, trouble-shooting and 

service for your appliance. Visit www.harmanstoves.com to 

find a dealer. We recommend annual service by a qualified 

service technician.

Follow the detailed instructions found in this section 

for each step listed in the chart below.

Shock and Smoke Hazard

•  Turn unit to the off position, let appliance 

completely cool and combustion fan must be off. 

Now you can unplug appliance before servicing.

•  Smoke spillage into room can occur if appliance 

is not cool before unplugging.

•  Risk of shock if appliance not unplugged before 

servicing appliance.

A. Proper Shutdown Procedure

CAUTION

!

NOTICE

The type of fuel you are burning will dictate how often you 

have to clean your burnpot. 

Clean more frequently if you 

encounter  heavy  build-up  of  ash  at  the  recommended 

interval or you see soot coming from the vent.

 Not 

properly cleaning your appliance on a regular basis 

will void your warranty.

Note:

 Do not use a household vacuum to clean the stove. 

We recommend that you use a shop vacuum that is equipped 

with a fine dust filter called a HEPA filter or a vacuum specially 

made for fly ash and soot. USING A VACUUM WHICH IS 

NOT EQUIPPED WITH A FINE DUST FILTER WILL BLOW 

FLY ASH AND SOOT OUT INTO THE ROOM.

NOTE:

 THE STOVE MUST BE COMPLETELY OUT BEFORE 

YOU VACUUM THE STOVE. LIVE PELLET EMBERS, IF 

SUCKED INTO THE VACUUM, WILL LIGHT THE VACUUM 

ON FIRE AND MAY ULTIMATELY CAUSE A HOUSE FIRE.

Summary of Contents for Accentra52i-TC

Page 1: ...Do not overfire If any external part starts to glow you are overfiring Reduce feed rate Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to co...

Page 2: ...tion instructions Contact local building or fire officials about restrictions and installation inspection in your area This wood heater needs periodic inspection and repair for proper operation Consul...

Page 3: ...Reference Materials A Service Parts 18 B Limited Lifetime Warranty 24 C Loss of Power Addendum 27 D Emergency Manual Ignition 27 E Troubleshooting 28 F Contact Information 30 1 Product Specifications...

Page 4: ...0 50 300 Vent Size 4 Inch Hopper Capacity 64 5 lbs Fuel Wood Pellet NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their specifications and or pr...

Page 5: ...able safety gate Never leave children alone near a hot stove whether operating or cooling down Teach children to NEVER touch the stove Consider not using the stove when children will be present Use on...

Page 6: ...esidence Before using the appliance have the venting system thoroughly inspected and replace any damaged components With any hearth appliance installation of smoke detectors is recommended on every le...

Page 7: ...Do not burn fuel that contains an additive May cause hopper fire Damage to product may result Read the list of ingredients on the packaging G Fuel Specifications Cont BURNING COLORED PAPER CARDBOARD...

Page 8: ...2017 ___ 09 17 8 3 90 00584c H Quick Start Guide 2 Fill hopper with pellets 3 Adjust arrows to set room desired temperature 4 Touch the On Off Power Icon Refer to Touch Manual for all other operations...

Page 9: ...as tall flames with black tails and is lazy The feed rate needs to be reduced or the burnpot needs cleaning Heat exchanger or exhaust blower needs cleaning Smoky start up or puffs of smoke from the ai...

Page 10: ...r If you did not fill hopper The message will disappear in 30 seconds Replace the 2 AA batteries in the Wireless Remote Sensor If Wireless Remote Sensor batteries die the Back Up Sensor will continue...

Page 11: ...ol before unplugging Risk of shock if appliance not unplugged before servicing appliance A Proper Shutdown Procedure CAUTION NOTICE The type of fuel you are burning will dictate how often you have to...

Page 12: ...t ashes into a steel non combustible container with tight fitting lid outside Use provided paint brush Vacuum loose ash from around igniter and inside burn pot Stove MUST be turned off cold and unplug...

Page 13: ...crape and Vacuum Heat Exchanger Cleaning the Heat Exchanger Removing the Center Medallion 1 Lift up on the 2 bottom corners of the medallion until it is higher than the top of the flame guide 2 Pull t...

Page 14: ...e top holed surface and sides of the burn pot down to auger tube as suggested in the Daily Weekly Maintenance Section Use the supplied allen wrench to remove any build up that may have accumulated in...

Page 15: ...on Cover in place Figure 2 10 In order to gain access to this area the medallion and cast rear covers must be removed Once cast components are removed pull up on cleanout cover latch to remove the cle...

Page 16: ...or long periods can result in etching due to the acidity of the ash Never clean the glass while it is hot and do not use abrasive substances Wash the surface with cool water and rinse thoroughly You m...

Page 17: ...e fireplace thoroughly vacuum around the Distribution Blowers Figure 2 17 Figure 2 17 Distribution Blowers Cleaning Venting System Its is recommend that a certified chimney sweep perform service and i...

Page 18: ...July 2017 Ending Manufacturing Date Part number list on following page Pellet Insert 24 Hopper 1 90 584240 1 Black 1 90 584240 14 Majolica Brown 20 Hopper 1 90 584200 1 Black 1 90 584200 14 Majolica...

Page 19: ...Y 9 Differential Switch 3 20 6866 Y Silicone Tubing 1 8 5 Ft 1 00 5113574 Y 10 Power Cord 14 3 20 584024 Y 11 Control Board Mounting Plate 1 10 584012A Power Board 1 00 05372 Y Gasket Hopper Top 20 f...

Page 20: ...de 5 Double Paddle Commonly required for Combustion Blower replacement 3 20 502221 Y Blower Mounting Screws 5 Sets 1 00 832150 32 Combustion Blower 1 00 02275 Y 33 Feeder Assembly See following page 3...

Page 21: ...sket 3 16 Round w PSA 10 FT 1 00 1186258229 Y 21 5 Glass w Gasket 1 00 677000 Y 21 6 Glass Clips Pkg of 4 1 00 249140 Y 21 7 Latch Retainer 2 00 674098S 21 8 Latch Trim Plate Enamel Only 2 00 674206P...

Page 22: ...31 3614087 4 Y 33 4 Gasket UL Feeder Cover 1 00 677122 Y 33 5 5 16 18 wing screw Pkg of 25 3 30 8012 25 33 6 UL Feeder Pusher Arm 1 10 677187W Y 33 7 UL Feeder Auger Assembly 3 50 00565 Y 33 8 Cam Bl...

Page 23: ...d serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM Description COMMENTS PART NUMBER Burn Pot Scraper Pkg of 10 2 00 777692 10 Communication Cable 3 20...

Page 24: ...or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier However the warranty shall commence no later than 24 months following the date...

Page 25: ...ome changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accid...

Page 26: ...not limited to improper chimney or venting installation LIMITATIONS OF LIABILITY The owner s exclusive remedy and HHT s sole obligation under this warranty under any other warranty express or implied...

Page 27: ...estart Since the fire is out the ESP temperature will not rise The unit will then shut down and may flash a six blink status error See ESP error codes If the fire is still burning it will resume norma...

Page 28: ...r has failed Partially burned pellets Feed rate too high Poor air to fuel mixture Check burn pot clean out cover and air intake Burn pot may need to be cleaned Combination of all the above Smoke smell...

Page 29: ...Harman Accentra52i TC Owner s Manual_R3 2017 ___ 09 17 29 3 90 00584c...

Page 30: ..._____ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________...

Reviews: