background image

Harman®  •  Accentra52i-TC Owner’s Manual_R3  •  2017 -___  •  09/17

2

3-90-00584c

Congratulations

, The Harman

®

 Accentra52i-TC pellet insert 

you have selected is designed to provide the utmost in safety, 

reliability, and efficiency.

As the owner of a new pellet stove, you’ll want to read and 

carefully follow all of the instructions contained in this owner’s 

manual. Pay special attention to all cautions and warnings.

This owner’s manual

 

should be retained for future reference. 

We suggest that you keep it with your other important 

documents and product manuals.

Your new Harman

®

 Accentra52i-TC Pellet Insert will give you 

years of durable use and trouble-free enjoyment. Welcome 

to the Harman

®

 family!

Read this manual before operating this appliance. 

Please retain this Owner’s Manual for future reference.

Read the Installation Manual before making any installation or finishing changes.

Listing Label Information/Location

The model information regarding your specific stove can be found on the 

rating plate usually located in the control area of the stove.

Ce poêle à granulés a été testé et peut être installé dans les maisons 

préfabriquées en conformité avec OAR 814-23-9000 à 814-23-909

PRÉVENTION DES INCENDIES 

Respecter scrupuleusement les 

instructions du constructeur pour l’installation et les consignes de 

fonctionnement. Respecter les règles de sécurité en vigueur dans votre 

région.

Ce poêle à bois doit inspection périodique et la réparation pour un 

fonctionnement correct. Consultez le manuel du propriétaire pour plus 

d’informations. Ce est contre les règlements fédéraux pour faire fonctionner 

ce poêle à bois d’une manière incompatible avec les instructions 

d’utilisation dans le manuel du propriétaire.

AVERTISSEMENT POUR MAISONS MOBILES:

 Ne pas installer dans 

une chambre. Il est impératif de prévoir une prise d’air extérieur. L’intégrité 

structurale du plancher, du plafond et des murs doit être strictement 

préservée. 

Se reporter aux instructions du fabricant et aux réglementations spécifiques 

locales concernant les précautions requises lorsque la cheminée traverse 

un mur ou un plafond fabriqué en matière combustible. 

Contrôler et nettoyer fréquemment tout le système d’évacuation des 

fumées conformément aux recommandations du constructeur.

Utiliser un conduit de fumée type « L » ou « PL » d’un diamètre de 7,6 cm 

(3”) ou de 10 cm (4”), ou bien une gaine en acier inoxydable de 10 cm (4”), 

comme indiqué dans le manuel d’utilisation.

Ne pas raccorder ce poêle à un conduit 

de cheminée déjà utilisé pour un autre 

appareil.

À UTILISER AVEC LA GRANULE DE BOIS 

SEULEMENT.

Émissions certifiés EPA: 1,1 g / h

Consommation maximum: 2,71 kg/h

Caractéristiques électriques:

120 V c.a. – 60 Hz – Intensité au 

démarrage 5,0 A 

Intensité en fonctionnement normal 4,0 A

DANGER: Risque d’électrocution. 

Débrancher l’appareil avant toute 

intervention.

Pour une information plus complète, se 

reporter à la notice d’utilisation.

Ne remplacer la vitre qu’avec une vitre 

céramique 5 mm disponible auprès de 

votre revendeur.

Garder la porte vitrée bien close 

durant le fonctionnement de l’appareil.

Tested to/Testé selon:

 ASTM E 

2779-10, ASTM E 2515-11, ASTM 

E 1509-12, ULC-S628-93

, Pellet 

Fuel-Burning Type, Also For Use In 

Mobile Homes. (UM) 84-HUD

“PREVENT HOUSE FIRES” 

Install and use only in accordance 

with the manufacturer’s installation and operation instructions. 

Contact  local  building  or  fire  officials  about  restrictions  and 

installation inspection in your area.
This wood heater needs periodic inspection and repair for proper 

operation. Consult the owner’s manual for further information. It is 

against federal regulations to operate this wood heater in a manner 

inconsistent with the operating instructions in the owner’s manual.
Room Heater, Pellet Fuel-Burning Type, Also for Use in Mobile 

Homes

WARNING: FOR MANUFACTURED HOMES:

 Do not install 

appliance in a sleeping room. An outside combustion air inlet must 

be provided. The structural integrity of the manufactured home 

floor, ceiling and walls must be maintained.

Refer to manufacturer’s instructions and local codes for precautions 

required for passing chimney through a combustible wall or ceiling.
Inspect and clean exhaust venting system frequently in accordance 

with manufacturer’s instructions.
Use a 3” or 4” diameter type “L” or “PL” venting system, or 4” 

stainless steel flex as per owner’s manual.
Do  not  connect  this  unit  to  a  chimney  flue  servicing  another 

appliance.

FOR USE WITH PELLETIZED WOOD FUEL ONLY.

EPA Certified Emissions: 1.1 g/hr
Input Rating Max: 6 lb. fuel/hr.
Electrical Rating: 120 VAC, 60 Hz, Start 3.5 AMPS, Run 2.5 AMPS

DANGER:

 

Risk of electrical shock. Disconnect power supply 

before servicing.

For further instruction refer to owner’s manual.
Replace glass only with 5mm ceramic available from your dealer.

Keep viewing door tightly closed during operation.
DO NOT REMOVE THIS LABEL/NE PAS ENLEVER CETTE 

ÉTIQUETTE

12” (305mm) Mantel

B

A

E

E

C

D

Sidewall/Mur latéral

Trim/Panneau de Moulure

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL

Non-combustible floor protector must extend 6” (152 mm) to the sides and 

front of the unit, measured from the glass face.

ÉCARTS MINIMUM DE SÉCURITÉ

La protection de sol doit être constituée de matériau incombustible et 

s’étendre de 152 mm (6”) à l’avant et sur les côtés de l’unité, mesurée 

depuis la vitre (ÉTATS-UNIS).

3-90-00584_R1

A.  Corps de l’insert à la paroi latérale - 12” (305mm)

B.  Corps de l’insert à 12” (305mm) Mantel - 12” (305 mm)

C.  Introduisez le corps de 3/4 “fascia ou couper au-dessus - 0” (0 mm)

D.  Corps de l’insert au bord latéral - 0” (0 mm)

E.  Protection de sol. Mesurée depuis la vitre. - 6” (152mm)

BARCODE LABEL

HF

Serial No.

N

o

 de série:

A.  Insert Body to side wall - 12” (305 mm)
B.  Insert Body to 12” (305mm) Mantel - 12” (305 mm)
C.  Insert Body to 3/4” fascia or trim above - 0” (0 mm)
D.  Insert Body to side trim - 0” (0 mm)
E.  Floor protection. Measured from glass. - 6” (152mm)

MODEL / MODÈLE: “Accentra 52i-TC Pellet Insert”

Room Heater Pellet Fuel-Burning Type

SUITABLE FOR MOBILE-HOME INSTALLATION

This pellet burning appliance has been tested and listed for use In

Manufactured Homes In accordance with OAR 814-23-900 through 814-23-909

Date of Manufacture / Date de fabrication:

2017   2018   2019   JAN   FEB   MAR   APR   MAY   JUN   JUL   AUG   SEP   OCT   NOV   DEC

Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032

US ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2020 particulate emission standards.
Certifié conforme aux normes 2020 d’émission de particules.

Made in U.S.A. of US and imported parts. / Fabriqué aux États-Unis-

d’Amérique par des pièces d’origine américaine et pièces importées.

Report #/Rapport #0135PN031S

LABEL TICKET

ECO:

LABEL SIZE:

11” x 5.75”

PART # / REV:

3-90-00584_R1

ADHESIVE:

N/A

ORIGINATOR:

Spidlet

MATERIAL:

24 Gauge Aluminum

DATE:

01/17

INK:

Screened Black Background

(2) Slotted Holes = .156 x .25

(2) Holes = Ø.2

(4) Corners = R.062

This unit will need the addendum label that refers to the 

“Wood heater needs periodic inspection” Information

352 Mountain House Road

Halifax, PA 17032

Serial Number

Model Name

EXAMPLE

Summary of Contents for Accentra52i-TC

Page 1: ...Do not overfire If any external part starts to glow you are overfiring Reduce feed rate Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to co...

Page 2: ...tion instructions Contact local building or fire officials about restrictions and installation inspection in your area This wood heater needs periodic inspection and repair for proper operation Consul...

Page 3: ...Reference Materials A Service Parts 18 B Limited Lifetime Warranty 24 C Loss of Power Addendum 27 D Emergency Manual Ignition 27 E Troubleshooting 28 F Contact Information 30 1 Product Specifications...

Page 4: ...0 50 300 Vent Size 4 Inch Hopper Capacity 64 5 lbs Fuel Wood Pellet NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their specifications and or pr...

Page 5: ...able safety gate Never leave children alone near a hot stove whether operating or cooling down Teach children to NEVER touch the stove Consider not using the stove when children will be present Use on...

Page 6: ...esidence Before using the appliance have the venting system thoroughly inspected and replace any damaged components With any hearth appliance installation of smoke detectors is recommended on every le...

Page 7: ...Do not burn fuel that contains an additive May cause hopper fire Damage to product may result Read the list of ingredients on the packaging G Fuel Specifications Cont BURNING COLORED PAPER CARDBOARD...

Page 8: ...2017 ___ 09 17 8 3 90 00584c H Quick Start Guide 2 Fill hopper with pellets 3 Adjust arrows to set room desired temperature 4 Touch the On Off Power Icon Refer to Touch Manual for all other operations...

Page 9: ...as tall flames with black tails and is lazy The feed rate needs to be reduced or the burnpot needs cleaning Heat exchanger or exhaust blower needs cleaning Smoky start up or puffs of smoke from the ai...

Page 10: ...r If you did not fill hopper The message will disappear in 30 seconds Replace the 2 AA batteries in the Wireless Remote Sensor If Wireless Remote Sensor batteries die the Back Up Sensor will continue...

Page 11: ...ol before unplugging Risk of shock if appliance not unplugged before servicing appliance A Proper Shutdown Procedure CAUTION NOTICE The type of fuel you are burning will dictate how often you have to...

Page 12: ...t ashes into a steel non combustible container with tight fitting lid outside Use provided paint brush Vacuum loose ash from around igniter and inside burn pot Stove MUST be turned off cold and unplug...

Page 13: ...crape and Vacuum Heat Exchanger Cleaning the Heat Exchanger Removing the Center Medallion 1 Lift up on the 2 bottom corners of the medallion until it is higher than the top of the flame guide 2 Pull t...

Page 14: ...e top holed surface and sides of the burn pot down to auger tube as suggested in the Daily Weekly Maintenance Section Use the supplied allen wrench to remove any build up that may have accumulated in...

Page 15: ...on Cover in place Figure 2 10 In order to gain access to this area the medallion and cast rear covers must be removed Once cast components are removed pull up on cleanout cover latch to remove the cle...

Page 16: ...or long periods can result in etching due to the acidity of the ash Never clean the glass while it is hot and do not use abrasive substances Wash the surface with cool water and rinse thoroughly You m...

Page 17: ...e fireplace thoroughly vacuum around the Distribution Blowers Figure 2 17 Figure 2 17 Distribution Blowers Cleaning Venting System Its is recommend that a certified chimney sweep perform service and i...

Page 18: ...July 2017 Ending Manufacturing Date Part number list on following page Pellet Insert 24 Hopper 1 90 584240 1 Black 1 90 584240 14 Majolica Brown 20 Hopper 1 90 584200 1 Black 1 90 584200 14 Majolica...

Page 19: ...Y 9 Differential Switch 3 20 6866 Y Silicone Tubing 1 8 5 Ft 1 00 5113574 Y 10 Power Cord 14 3 20 584024 Y 11 Control Board Mounting Plate 1 10 584012A Power Board 1 00 05372 Y Gasket Hopper Top 20 f...

Page 20: ...de 5 Double Paddle Commonly required for Combustion Blower replacement 3 20 502221 Y Blower Mounting Screws 5 Sets 1 00 832150 32 Combustion Blower 1 00 02275 Y 33 Feeder Assembly See following page 3...

Page 21: ...sket 3 16 Round w PSA 10 FT 1 00 1186258229 Y 21 5 Glass w Gasket 1 00 677000 Y 21 6 Glass Clips Pkg of 4 1 00 249140 Y 21 7 Latch Retainer 2 00 674098S 21 8 Latch Trim Plate Enamel Only 2 00 674206P...

Page 22: ...31 3614087 4 Y 33 4 Gasket UL Feeder Cover 1 00 677122 Y 33 5 5 16 18 wing screw Pkg of 25 3 30 8012 25 33 6 UL Feeder Pusher Arm 1 10 677187W Y 33 7 UL Feeder Auger Assembly 3 50 00565 Y 33 8 Cam Bl...

Page 23: ...d serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM Description COMMENTS PART NUMBER Burn Pot Scraper Pkg of 10 2 00 777692 10 Communication Cable 3 20...

Page 24: ...or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier However the warranty shall commence no later than 24 months following the date...

Page 25: ...ome changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accid...

Page 26: ...not limited to improper chimney or venting installation LIMITATIONS OF LIABILITY The owner s exclusive remedy and HHT s sole obligation under this warranty under any other warranty express or implied...

Page 27: ...estart Since the fire is out the ESP temperature will not rise The unit will then shut down and may flash a six blink status error See ESP error codes If the fire is still burning it will resume norma...

Page 28: ...r has failed Partially burned pellets Feed rate too high Poor air to fuel mixture Check burn pot clean out cover and air intake Burn pot may need to be cleaned Combination of all the above Smoke smell...

Page 29: ...Harman Accentra52i TC Owner s Manual_R3 2017 ___ 09 17 29 3 90 00584c...

Page 30: ..._____ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________...

Reviews: