B1140 Winch
24
Technical information on hydraulic motor
Characteristics of the Parker hydraulic motors installed to operate the 1140 winch (table 9):
Table 9
For both hydraulic motors:
Input/return tube thread: 7/8 – 14 SAE
Drainage tube thread: 7/16 – 20 straight thread
Note (1):
any flow range within the limits indicated is acceptable
Hydraulically operated winches have a load capacity proportional to the working pressure of the system, while the line
recovery speed is proportional to the oil flow.
Table 10
Note (2):
with very high flow values, for example 60 Lt/min, the gearing will need a more frequent maintenance cycle.
Capacity
Maximum
Recommended flow
recommended
range
(1)
pressure
Backwind motor
(Parker 111A-071 AS-O)
Main motor
(Parker 111A-129 AS-OSW)
116 c.c.
160 bar (2400 psi)
From 15 to 60 Lt/min
(from 4 to 16 gal/min)
211 c.c.
200 bar (3000 psi)
From 15 to 60 Lt/min
(from 4 to 16 gal/min)
1
st
speed
2
nd
speed
3
rd
speed
Maximum load
(at 200 bar with 20 mm line)
Maximum recovery speed
(with 15 Lt/min flow and 20 mm line)
Maximum recovery speed
(with 60 Lt/min flow
(2)
and 20 mm line)
900 kg
3420kg
9750kg
29 mt/min
7 mt/min
2 mt/min
98 mt/min
24 mt/min
7 mt/min
Summary of Contents for B 1140 Series
Page 1: ...WINCH MANUAL B1140 WINCH MANUAL...
Page 7: ...B1140 Winch 7 Technical information and characteristics Exploded view Fig 3...
Page 8: ...B1140 Winch 8 Technical information and characteristics Exploded view Fig 4...
Page 15: ...B1140 Winch 15 Fig 9 Technical information and characteristics Exploded view...
Page 16: ...B1140 Winch 16 Fig 10 Technical information and characteristics Exploded view...
Page 44: ...B1140 Winch 44 Maintenance Esploded view Fig 41...