![Harken 46 Rewind STA EL Installation And Maintenance Manual Download Page 12](http://html1.mh-extra.com/html/harken/46-rewind-sta-el/46-rewind-sta-el_installation-and-maintenance-manual_597642012.webp)
12
46 Rewind ™ Radial Winch
Installation and Maintenance Manual
Fasten the Dual Function Control Box containing solenoids to bulkhead or wall: refer to the
Dual Function Control Box manual. Install remote circuit breaker between power supply
and Dual Function Control Box. Locate push-buttons on deck in a convenient spot for easy winch
operation: refer to the Digital System Switch manual.
Refer to the following chart for wire size:
Total distance between winch and battery
Winch
Current
voltage
Under
16.4 ft
AWG
Under 5 m
mm
2
16.4 - 32.8 ft
AWG
5 m - 10 m
mm
2
32.8 - 49.2 ft
AWG
10 m - 15 m
mm
2
49.2 - 65.6 ft
AGW
15 m - 20
m
mm
2
46 Rewind
™
12 V
2
32
0
50
00
70
000
95
46 Rewind
™
24 V
5
16
3
25
2
35
0
50
NOTICE
To connect motor, attach cable terminals to clamps between
nut and lock nut. Hold nut in contact with motor using a
spanner and tighten other nut with second spanner. Take
special care not to turn the central spindles. Be careful not
to turn central spindles. These instructions apply when
assembling and disassembling. We recommend using a
torque wrench so as to obtain a torque equal to and no
greater than 10 Nm (88 in-lb).
NOTICE
Note that correct electrical contact sequence is:
Nut – Cable Terminal – Self-Locking Washer – Lock Nut