GAS CYLINDERS 

 

1.  This appliance shall be used with NATURAL and LP inlet gas supply only.  The LP or CNG gas supply cylinder must be 

constructed and marked in accordance with the specifications for LP-gas cylinders or CNG-gas cylinders of the U.S. 
Department of Transportation (DOT). 

 
2.  The use or storage of the LP or CNG cylinder may not be used in a building, garage or any other enclosed area. 

 

3.  Cylinders must be stored outdoors in a well-ventilated area out of the reach of children.  Disconnected cylinders must 

have threaded valve plugs tightly installed. 

 

4.  If the appliance is not in use, the gas must be turned off at the supply cylider. 

 

5.  Inspect the hose before each use of the appliance.  The hose assembly must be replaced prior to the appliance being put 

into operation if there is evidence of excessive abrasion or wear, or if hose is damaged.  The hose assembly must be 
replaced with a replacement hose assembly equivalent to, or greater than, rating specified on the original hose. 

 

6.  The gas hose shall be located out of pathways where people may trip over it or in areas where the hose may be subject to 

accidental damage. 

 

7.  Never use matches or open flame to test for leaks.  Use soapy water or a leak detector. 

 

8.  Do not store or use a LP-gas supply cylinder around excessive heat; the cylinder may get too hot or cause the pressure to 

rise.  Store the cylinder in a secure upright position. 

 

9.  Cylinders must be fully opened and the pressure controlled by a reducing pressure regulator to operate properly.  

 
 

ENCLOSURES FOR LP/CNG GAS SUPPLY SYSTEMS 

 

1.  Enclosures for LP-gas supply cylinders and CNG-gas supply cylinders must be ventilated by openings at the level of the 

cylinder valve and at floor level.  This may be accomplished by one of the following: 

a.  One side of the enclosure must be open.  

See Figure 1

 

 
b.  For an enclosure having four sides, a top and bottom, at least two ventilation openings at cylinder valve level must be 

provided in the side wall, equally sized, spaced at 180 degrees and unobstructed.  Each opening must have a total free 
area of not less than 1/2 square in per pound (3.2sq. cm/kg) of stored fuel capacity and not less than a total free area of 10 
square inches (64.5 sq. cm).  

Ventilation opening(s) must be provided at floor level

 and have a total free area of not 

less than 1/2 square inch per pound (3.2 sq. cm/kg) of stored fuel capacity and not less than a total free are of 10 square 
inches (64.5 sq. cm).  If ventilation openings at floor level are in a side wall, there must be at least two openings.  The 
bottom of the openings must be at floor level.  The openings shall be equally sized, spaced at 180 degrees and 
unobstructed.  

See Figure 2

 

 
*There must be a minimum clearance of 2 inches (50.8 mm) between the lower surface of the floor of the cylinder enclosure 

and the ground. 

*The cylinder enclosure must be such that the cylinder can be connected, disconnected and the connections inspected and 

tested outside the cylinder enclosure.  Cylinder valves must be readily accessible for hand operation.  A door on the 
enclosure to gain access to the cylinder valve is acceptable, provided it is non-locking and can be opened without the use 
of tools. 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 

Figure 1 

Figure 2 

Summary of Contents for Firepit Burners

Page 1: ...fice specifically for the input gas and Btu rating Modifying or failure to use the factory orifice may cause property damage personal injury or loss of life This equipment is intended for use with an input of Natural or Propane gas only Clothing or other flammable materials should not be hung from the appliance or placed on or near the appliance Children and adults should be alerted to the hazards...

Page 2: ...The firepit should be examined prior to use and inspected by a qualified agency The burner should be cleaned annually by a qualified agency 6 To clean the burner shut off and disconnect the gas supply use a pipe cleaner to clean out burner ports and vacuum the inside of the burner by removing the orifice air mixer fitting from the inlet of the burner After the burner is cleaned attach the orifice ...

Page 3: ... to operate properly ENCLOSURES FOR LP CNG GAS SUPPLY SYSTEMS 1 Enclosures for LP gas supply cylinders and CNG gas supply cylinders must be ventilated by openings at the level of the cylinder valve and at floor level This may be accomplished by one of the following a One side of the enclosure must be open See Figure 1 b For an enclosure having four sides a top and bottom at least two ventilation o...

Page 4: ...heel burner Fire ring if ordered in 36 Hose kit with key valve Non whistling flex connector 1 2 to 3 8 brass reducing elbow Brass elbow orifice holder Orifice 2 bigger orifice hole for NG smaller hole for LP Pipe reducing fitting 1 3 Volcanic Cinder One 5 gal bucket for 18 24 2 buckets for 30 36 These pieces come with the FPTP22 but are not used in this accessory kit 3 4 5 6 7 8 9 ...

Page 5: ...the holes will be face down to keep out water and any other debris from falling inside This will not affect flame height LIGHTING INSTRUCTIONS 1 STOP Read the Gas Cylinder Important Information and Enclosures sections before attempting to light this appliance 2 BEFORE LIGHTING Smell all around the appliance area for gas Be sure to smell next to the floor of the firepit because some gas is heavier ...

Page 6: ...ifice The bigger orifice hole is for NG 7 Attach the pipe reducing fitting over the orifice 8 Connect the pipe reducing fitting to the fire wheel on the side with holes 9 Finally connect the plug that came with the fire wheel to the other side Note that the holes will be face down to keep out water and any other debris from falling inside This will not affect flame height CAUTION WHEN BURNING THE ...

Page 7: ...ranty applicable to this appliance is limited in duration to the same period of time as this written warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRI...

Reviews: