2-9 Priming the Pumps
Once the furnace has been filled with water, the system pump an anti-stratification
circulator comes pre-installed and must run continuously.
This circulator should not be modified and must not be used in conjunction with any
other application.
You will need to open the supply valves and the return valves on the pump. Plug the
power cord for the circulator pump into the GFCI receptacle, and listen for the air
bubbling back into the water tank. Once you no longer hear air bubbling, slowly close
the supply valve above the pump until you hear a change in the sound the water
makes as it flows through the pump. Once you are satisfied that the pump is moving
water open the supply valve back up.