HARDY MANUFACTURING CO., INC (MODEL KB125) PAGE 10
2-7
Installation of Smoke Stacks
The KB125 comes with two three foot sections of smoke stack and a stack ring. Push
the two smoke stacks into one another. Then place the stack ring onto the top section.
Last install the combined stacks into the units flu gas exit hole on the roof. Pay close
attention while working above the unit top when installing the stacks. Don’t apply to
much pressure or drop any tools as the stainless steel roof can be scratched and bent.
F
Smoke Stack
Do not seal Vent Cap
To Vent Pipe.
Vent Pipe.
Smoke Stack Collar