![Hardy Barth CPMICRO1 Instruction Manual Download Page 19](http://html1.mh-extra.com/html/hardy-barth/cpmicro1/cpmicro1_instruction-manual_3899518019.webp)
Taking into operation and charging process
After the mechanical and the electrical installation, your charging station is immediately
ready. The cPµ1 possesses a Type 1 or Type 2 charging cable complying with IEC 62196-2
for charging (depends on variant).
The Type-2 charging cable of the cPμ1 has
three live conducting pins, a neutral
conductor, a PE conductor and two signalling
contacts (
C
ontrol
P
ilot and
P
roximity
P
ilot),
which provide a safe connection without
danger.
Only when the plug of the charging cable is
interlocked with the charging socket, voltage
will be output through the conducting pins
and the charging process will start.
The cPµ1 is equipped with a DC fault-current-
circuit breaker which automatically interrupts
in case of leakage current. Thereby it is not
necessary to install a Type B fault-current-
circuit-breaker in the pre-distributor. A Type
A fault current circuit breaker suffices.
Instruction Manual
cPμ1
charging station
Version: 1.3.3
19