Hardy Barth CPMICRO1 Instruction Manual Download Page 14

Preparing the installation 

Several requirements regarding the mounting site and connection technology must be met for

the installation in order to guarantee a safe operation.

Requirements for mounting site

The cPμ1 charging station was developed for indoor as well as outdoor areas.  As user, please
note   the   following   requirements   for   the   mounting   site   and   installation   to   ensure   safe

charging later on.

• Follow all local regulations concerning electrical installation, fire prevention and

accident prevention

• All regulations to installation a low voltage system according to IEC 60364-1- and

IEC 60364-5-52 apply to any times.

• The   mounting   surface   has   to   be   steady   and   solid   enough   to   withstand

mechanical pressure.

• The installation position has to provide a lead big enough for the power supply
• Do not install the Wallbox at crowded areas or passage ways. Please make sure

to lay all charging cables in sight and pedestrians or routes are NOT obstructed

in any way.

• Even though basically the cPµ1 is constructed to operate in an environment

with   high   temperatures,   it   is   highly   recommended   to   install   the   charging

station at a place, where it is protected of direct sun irradiation. This way,

overheat of the housing can be prevented. You can find more information to

environmental conditions in section “Technical specifications” on page 24.

Instruction Manual 

cPμ1

 

charging station

Version: 1.3.3

14

Summary of Contents for CPMICRO1

Page 1: ...Charging Station cP 1 Instruction Manual Instruction Manual cP 1 charging station Version 1 3 3 1 English English...

Page 2: ...er eCHARGE Hardy Barth GmbH Leinbergstra e 14 92262 Birgland Schwend Germany Phone 49 0 9666 188 1350 Fax 49 0 9666 188 1351 Web www echarge de E Mail support echarge de Instruction Manual cP 1 chargi...

Page 3: ...ing the installation 14 Requirements for mounting site 14 Installation and taking into operation 15 Mechanical installation on wall 16 Electrical installation of charging station 17 Taking into operat...

Page 4: ...Danger Sections marked with this symbol indicate electrical voltages that represent danger to life and limb Actions marked with this symbol must not be carried out under any circumstances Caution Sect...

Page 5: ...also inside the device These symbols carry the following meanings Attention Only qualified staff which are familiar with this manual this document are allowed to open the cp 1 Attention Dangerous ele...

Page 6: ...he desired installation place as well as the proper operation of the device Disregard of or actions contrary to the safety information and instructions contained in this manual may lead to electric sh...

Page 7: ...g water or jetting water The cP 1 is sufficiently protected against spray and splash according to IP44 The cP 1 must not be installed in an environment prone to or with danger of explosion EX area Do...

Page 8: ...with tensile strength when it is connected Make sure that the front side of the housing cover is always closed to prevent unauthorized opening DO NOT modify the housing or the wiring inside the Wallb...

Page 9: ...ing cable please replace them immediately No further charging is allowed in this case DANGER If you find damage on the housing charging sockets or corresponding charging cables after installation take...

Page 10: ...after being completely assembled and tested Below all measurements and assembly points are detailed in the dimensional drawings Charging station Front view and side view of the cP 1 series all specif...

Page 11: ...g in an integrated network the charging station will allow nearly 100 power usage consisting solely of solar electricity The charging stations of the cP series are constantly developed further and at...

Page 12: ...on equipment Via two LED lights on the housing the user is always informed about the current state of the charging station Identifying your product variant The cP series consists of multiple variants...

Page 13: ...ble cover Instruction for assembly and operation 1 Contains instructions for mechanical and electrical installation as well as taking into operation this document Available accessories eCHARGE offers...

Page 14: ...364 5 52 apply to any times The mounting surface has to be steady and solid enough to withstand mechanical pressure The installation position has to provide a lead big enough for the power supply Do n...

Page 15: ...r outdoors various environmental conditions To ensure safe operation comply with minimum distances to other technical constructions Further information can be obtained upon asking your distributor or...

Page 16: ...play 2 Mark the four drill holes on the wall by using the charging station as template 3 Drill the previously marked spots 6 mm 4 Insert the included screw anchors for the fastening screws 5 Position...

Page 17: ...ve component For the electrical installation the following tools will be needed A slotted screwdriver with maximum width of 4 mm not included in scope of delivery A Torx screwdriver or Torx Bit TX20 n...

Page 18: ...electrical company and have them examine the lead and if required replace it 4 Plug the LED Display back in and re attach the cover of the charging station before securing it with its screws 5 Reacti...

Page 19: ...cts Control Pilot and Proximity Pilot which provide a safe connection without danger Only when the plug of the charging cable is interlocked with the charging socket voltage will be output through the...

Page 20: ...e to connect the external charging cable to your electric vehicle without putting it under tension or straining it otherwise Make sure that your cP 1 is properly connected to the lead Make sure that t...

Page 21: ...st not be strained during the charging process 3 Charging will start as soon as the cable connects with the socket of your vehicle Upon starting the LEDs colour will change to blue Completion of charg...

Page 22: ...The LED Display on the front cover shows the current operating condition For visualization the LEDs can glow they are permanently turned on not glow they are permanently turned off When in normal mod...

Page 23: ...ct your local distributor The LEDs of the display are damaged If the LEDs are defect please contact your local distributor or the previously deployed electrician so they can be exchanged The electric...

Page 24: ...and an automatic cut out C16 A C20 A Charging cable 1 x Type 2 20 A 16 A 1 x Type 1 16 A Charging controller EVCC charge controller phoenix Load management Dynamic with external eCB1 module Environmen...

Page 25: ...art 22 alternating current charging station for electric vehicles DIN EN 61851 1 2012 01 Conductive charging systems for electric vehicles part 1 general requirements E DIN EN 61851 22 2011 04 Conduct...

Page 26: ...onductive components of the operating device are connected low impedance with the protective conductor system of the fixed installation IP 44 Protection type of housing Protection against foreign obje...

Page 27: ...your local distributor or an authorized representative to clarify whether the malfunction is covered by guarantee and or warranty provisions Do not under any circumstances make alterations or repairs...

Reviews: