Appendix
Technical specifications
Variant
cPH1
Power line
For lead of size 5 x 6 mm
2
Rated nominal voltage
230 / 400 V
Rated nominal current
16 A/ 32 A, 3-phase
Nominal frequency
50 Hz
Maximum charging capacity
22 kW
Protective switches
DC fault-current detection 6 mA (built in)
and circuit breaker C16 A/ C32 A (built in,
depends on variant);
additionally required:
fault-current circuit breaker of Type A, 40 A,
0,03 A
Charging socket/charging cable
2 x Type 2, 16 A/ 32 A
Charging controller
2 x EVCC
Access
RFID Mifare
Load management
Dynamic with eCB1-Module
Environmental temperature
-30 to 50° C
Storage temperature
-30 to 85° C
Relative humidity
5 to 95% (non-condensing)
Class of protection
I
Over-voltage category
III
Degree of contamination
3
Type of protection for cover
IP44
Dimensions
497mm x 397mm x 166mm (HxWxD)
Weight per unit
approx. 10.5 kg
Product number
3M2XXXX
Instruction Manual
cPH1
charging station
Version: 1.2.4
27