background image

Charging Station

cPH1

Instruction Manual

Instruction Manual 

cPH1

 

charging station

Version: 1.2.4

1

E

n

g

li

s

h

Summary of Contents for cPH1

Page 1: ...Charging Station cPH1 Instruction Manual Instruction Manual cPH1 charging station Version 1 2 4 1 English ...

Page 2: ...acturer eCHARGE Hardy Barth GmbH Leinbergstraße 14 92262 Birgland Schwend Phone 49 0 9666 188 1350 Fax 49 0 9666 188 1351 Web www echarge de E Mail support echarge de Instruction Manual cPH1 charging station Version 1 2 4 2 ...

Page 3: ...g the Installa on 14 Requirements for moun ng site 14 Installa on and taking into opera on 15 Mechanical installa on on wall 15 Electrical installa on of charging sta on 16 Taking into opera on and charging process 19 Safety no ces for opera on 20 Prepara on for RFID access 20 Charging process 21 Par culari es 23 Opera on status 24 LED Display 24 RFID Module op onal 25 Interrup on of opera on and ...

Page 4: ...nd follow the provided safety notices in any circumstances In particular the warnings and safety measures clearly marked in this manual must be followed The associated symbols carry the following meanings Please note Sections marked with this symbol indicate further important information and particularities which are necessary for a proper functioning device Instruction Manual cPH1 charging statio...

Page 5: ...eploying non qualified professional staff This device represents the current state of technology and fullfills all current technical safety requirements directives and norms The provided safety information serve to ensure a safe installation at the desired installation place as well as the proper operation of the device Disregard of or actions contrary to the safety information and instructions co...

Page 6: ... the charging station does not work properly or is damaged otherwise Please also note the following Do not install the charging station in close vicinity of running water or jetting water The cPH1 is sufficiently protected against spray and splash according to IP44 The cPH1 must not be installed in an environment prone to or with danger of explosion EX area Do not install the charging station in a...

Page 7: ...d with tensile strength when it is connected Make sure that the front side of the housing cover is always closed to prevent unauthorized opening DO NOT modify the housing or the wiring inside the Wallbox in any case Violation contravenes the guarantee specifications and annul the warranty immediately There are no components inside the product that will need to be maintained by the user Only deploy...

Page 8: ...e please replace them immediately No further charging is allowed in this case DANGER If you find damage on the housing charging sockets or corresponding charging cables after installation take the Wallbox out of order immediately and contact the service department of eCHARGE Hardy Barth GmbH The local regulations of operating electrical devices apply at any time Instruction Manual cPH1 charging st...

Page 9: ...red after being completely assembled and tested Below all measurements and assembly points are detailed in the dimensional drawings Charging station Front view and side view of cPH1 series all specifications are in mm Instruction Manual cPH1 charging station Version 1 2 4 9 ...

Page 10: ...ugh the built in RFID Module optionally available all charging processes can be efficiently conducted and controlled while the integrated energy meter provides precise measurement The determined data is displayed in real time on a smartphone tablet or pc for external utilization The charging stations of the cPH series are constantly developed further and at all times comply with regulations and no...

Page 11: ... E offers additional cables e g a charging cable with Type 2 plug on both ends or an adapter cable Type 2 to Type 1 for electric vehicles with Type 1 charging sockets Alternatively the cPH1 is also available with a Schuko plug socket Your distributor can provide further information We set maximum value on the user s safety on all of our products Therefore the cPH1 Wallboxes offer effective protect...

Page 12: ...tion plate Open the housing cover before installation and operation in order to verify the type of variant with help of the identification plate In particular the model description cPH1 XTYY and data of the power supply voltage power frequency current are relevant for identification Detailed information to cPH1 charging stations can be found in section Technical specifications on page 29 Instructi...

Page 13: ...owing additional accessories for your cPH1 charging station Illustration Description Item number Charging cable Type 2 to connect all cPH1 charging stations and vehicles with charging sockets according to IEC 62196 2 Type 2 32 A 240 415 V AC protection against spray and splash IP44 Length 5 Meters 3M40504 Adapter cable Type 2 to Type 1 to connect all cPH1 charging stations and vehicles with chargi...

Page 14: ...withstand mechanical pressure The installation position has to provide a lead big enough for the power supply Depending on your variant two separate leads are also possible Do not install the Wallbox at crowded areas or passage ways Please make sure to lay all charging cables in sight and pedestrians or routes are NOT obstructed in any way Even though basically the cPH1 is constructed to operate i...

Page 15: ...n places easily accessible to persons authorized for usage Choose the place of installation accordingly so the charging cable of the cPH1 can reach the charging socket of your electric vehicle without any further problems UNDER NO CIRCUMSTANCES should the cable be strained with tensile strength while it is connected with your EV Mechanical installation on wall Additionally the following components...

Page 16: ...ER Danger to life due to electric shock Before working with the cPH1 charging station Disconnect the electrical power supply and make sure that it stays disconnected non stop through the whole installing process After completion of the mechanical installation the charging station will be connected to the power line In the following instructions on how to connect additional accessories are not show...

Page 17: ...an unplug it 3 Turn off all circuit breakers and all fault current circuit breakers inside the charging station switch position 0 OFF 4 Insert the lead from below into the respective cable glands Clamp the stripped glands of the lead into the lead terminal blocks according to the labels 6mm 4 1 Single lead 4 2 Double lead Description Colour of core Label Live conductor Phase 1 BROWN EUROFUSE NH00 ...

Page 18: ...ck is A 6 Turn the circuit breakers and fault current circuit breakers back on Switch Position I ON The LED lights will glow green 7 To re attach the front cover 7 1 first plug the LED Display back in and put it on top of the charging station 7 2 Then close the charging station by re attaching the front cover 7 3 Secure it with the two screws on the bottom of the front cover The electrical install...

Page 19: ...The Type 2 charging cable of the cPH1 has three live conducting pins a neutral conductor a PE conductor and two signalling contacts Control Pilot and Proximity Pilot Only when the plug of the charging cable is interlocked with the charging socket voltage will be output through the conducting pins and the charging process will start The charging socket of the cPH1 has an electromotive interlock whi...

Page 20: ...sed during normal operation Make sure that the external charging cable is not twisted and assure yourself that the cable and cover do not have any visible damages Preparation for RFID access You can set up identification of users to restrict or authorize charging process for authorized persons with the integrated RFID Reader Registration at the cPH1 has to be done through the RFID conformable tran...

Page 21: ...rging socket of your vehicle Park the EV accordingly so you can reach it comfortably During the charging process the cable MUSTN T be strained 4 Open the cover of your charging socket of the cPH1 if available with your variant and plug in your Type 2 charging cable PLEASE NOTE If the used charging plug socket does not require RFID authentication the charging process will start immediately In this ...

Page 22: ...ss time control can only function permanently if the eCB1 module has access to a time server NTP 7 The charging process will not be terminated by the charging station but only by the vehicle itself Based on communication between the cPH1 and your vehicle the charging station will give notification by switching the LED colour from blue back to green This is to signify that you can remove the chargi...

Page 23: ...rminated Continuation of charging can only be issued after unplugging and re authentication via the RFID module PLEASE NOTE Unplugging the charging cable during reserved mode will terminate the reservation PLEASE NOTE A flawless time control can only function permanently if the eCB1 module has access to a time server NTP 2 Charge control While one or more vehicles are charging you can actively con...

Page 24: ... shows the current operation condition For visualization the LED lights can glow they are permanently turned on not glow they are permanently turned off When in normal operation mode the following colors and states are displayed as follows Colour code Description Green The charging station charging socket is ready You can connect the vehicle to charge at any time Blue The electric vehicle is curre...

Page 25: ...conds and the charging process will start If the LED light flashes three times these could be the reasons The RFID card is not activated or there is a charging cable connected to the second charging socket which has not been reserved or activated In these cases the charging process will not start If two charging sockets shall be activated at the same time unplug one of the charging cables and re r...

Page 26: ... internal RCCB of the cPH1 is triggered Please check the status of the RCCB and plug it back in by the rocker arm The LEDs of the display are damaged If the LEDs are defect please contact your local distributor or previously employed electricians so they can be exchanged The electric vehicle is not recognized The charging cable is not plugged in correctly Remove the charging plug from the vehicle ...

Page 27: ...ault current circuit breaker of Type A 40 A 0 03 A Charging socket charging cable 2 x Type 2 16 A 32 A Charging controller 2 x EVCC Access RFID Mifare Load management Dynamic with eCB1 Module Environmental temperature 30 to 50 C Storage temperature 30 to 85 C Relative humidity 5 to 95 non condensing Class of protection I Over voltage category III Degree of contamination 3 Type of protection for co...

Page 28: ...c vehicles part 22 alternating current charging station for electric vehicles DIN EN 61851 1 2012 01 Conductive charging systems for electric vehicles part 1 general requirements E DIN EN 61851 22 2011 04 Conductive charging systems for electric vehicles part 22 alternating current charging station for electric vehicles HD 60364 7 722 2012 Installation of low voltage systems part 7 22 power supply...

Page 29: ...ically conductive components of the operating device are connected low impedance with the protective conductor system of the fixed IP 44 Protection type of housing Protection against foreign objects 1mm and protection against splashing from every direction Instruction Manual cPH1 charging station Version 1 2 4 29 ...

Page 30: ...ages and liability This includes claims which are attributable to the following causes 1 Deterioration due to normal wear and tear corrision damage accident incorrect storage or operation lack of reasonable and necessary maintance 2 Wallbox installation services carried out by unauthorised persons by an unauthorised electrician installers not auhorised by eCHARGE Hardy Barth GmbH or the customer h...

Page 31: ...l or manufacturing defects In these cases the manufacturer will attempt to restore the proper functioning of the product in cooperation with the local distributor Any costs incurred for the transport of the product shall be borne by the customer If the serial number has been removed from the wallbox through the fault of the customer or if it has been altered or is illegible all rights granted unde...