99
7 - Fault finding
Operational problems
General info
Operational incidents are frequently due to the same reasons:
1.
A suction leak reduces the pump pressure and may interrupt suction completely, it also causes pulsing in the pressure
hoses.
2.
A clogged suction filter may damage suction or interrupt and prevent the pump from running normally.
3.
A clogged pressure filter increases pressure in the fluid system in front of the pressure filter. This may blow the safety
valve.
4.
Clogged In-line or nozzle filters increase pressure in the pressure gauge but decrease pressure at the nozzles.
5.
Impurities sucked by the pump may prevent the valves from closing correctly, thus reducing the pump flow.
6.
A poor reassembly of the pump elements, especially the diaphragm covers, causes air leaks and reduces the pump
flow.
7.
Rusted or dirty hydraulic components cause bad connections.
8.
A badly charged or faulty battery causes failures and misbehaviour in the electrical system.
Therefore ALWAYS check
1.
Suction and pressure filters, as well as nozzles, are clean.
2.
Hoses for leaks and cracks, paying particular attention to suction hoses.
3.
Gaskets and O-rings are present and in good condition.
4.
Pressure gauge is in good working order. Dosage accuracy depends on it.
5.
Operating unit functions properly. Use clean water to check.
6.
Hydraulic components are clean.
7.
The good condition of the tractor battery and its connectors.
Summary of Contents for Mercury Series
Page 1: ...Mercury Zaturn Instruction book 67029104 100 Version 1 00 GB 10 2016 www hardi com au...
Page 6: ...6...
Page 64: ...4 Sprayer setup 64...
Page 77: ...5 Operation 77...
Page 102: ...7 Fault finding 102...
Page 106: ...8 Technical specifications 106 Specifications Pump Model 464 10 0 4 40 2 2 2 20...
Page 112: ......
Page 114: ...HARDI Australia P L 534 538 Cross Keys Rd Cavan SA 5094 AUSTRALIA...