background image

6

Press

BATTERY TYPE button

and hold for 3 seconds to go into your battery type

selection mode, the battery type you select will be shown on the LCD meter, the default
setting is AGM Battery; the controller will automatically memorize your battery type
setting.

Li-ion battery shown in LCD indicates 3-SERIES Li-ion battery shown as below:

-- Lithium Cobalt Oxide LiCoO2 (LCO) battery

-- Lithium Manganese Oxide LiMn2O4 (LMQ) battery

-- Lithium Nickel Manganese Cobalt Oxide LiNiMnCoO2 (NMC) battery

-- Lithium Nickel Cobalt Aluminum Oxide LiNiCoAlo2 (NCA) battery

LiFePO4 battery shown in LCD indicates Lithium Iron Phosphate battery, LFP battery.

LTO battery shown in LCD indicates Lithium Titanate Oxide, Li4Ti5O12 battery.

Caution: Incorrect battery type setting may damage your battery.

When the controller powers on, the unit will run self-qualify mode and automatically show

below items on LCD before going into charging process

Self-test starts, digital meter segments test

Software version test

Rated voltage and current test

External battery temperature sensor test (if connected)

After going into charging process, the LCD displays the charging statues as below:

Press

VOLT / AMP button

in sequence, the LCD will display in turn with

Battery Voltage, Charging Current, Charged capacity (Amp-hour) and Battery

Temperature (if external temperature sensor connected)

Display in the day time

-

Display during the night

-

Display when battery fully charged

Press

VOLT / AMP button

in sequence, the LCD will display in turn with

Battery Voltage, Charging Current, if you do not press the button, the LCD will

alternatively display the FUL and VOLT or FUL and AMP every 2 seconds

Summary of Contents for KOR12-10

Page 1: ...1 Solar Controller Battery Charger User s Manual ...

Page 2: ...ge provided you have satisfactory proof of purchase keep your receipt There are three standard versions of HARD KORR PWM controllers KOR12 10 Rated for 12V solar panel Max 25V Rated maximum output current of 10Amp KOR12 15 Rated for 12V solar panel Max 25V Rated for maximum output current of 15Amp KOR12 20 Rated for 12V solar panel Max 25V Rated for maximum output current of 20Amp RISK OF EXPLOSIV...

Page 3: ...Common negative grounding connection High efficiency and low power consumption Battery type setting and battery condition indication Smart charging control Charging time management LED indication for the battery condition and charging statues Digital display charging parameters and battery settings Automatically active to Lithium battery against BMS protection Thermal protection Over voltage prote...

Page 4: ...s 4 terminals which are clearly marked Solar and Battery There is a 12V and earth GND terminal for each circuit Refer to the wiring diagram as shown below please cover the solar panel before connecting cables WIRING CONNECTIONS ...

Page 5: ...start working automatically Please check your battery manufacturer s specifications to select correct battery type The unit provides 7 battery types for selections Lithium ion LiFePO4 LTO Gel AGM WET conventional lead acid and Calcium battery OPERATION LCD DISPLAY ...

Page 6: ...ct battery type setting may damage your battery When the controller powers on the unit will run self qualify mode and automatically show below items on LCD before going into charging process Self test starts digital meter segments test Software version test Rated voltage and current test External battery temperature sensor test if connected After going into charging process the LCD displays the ch...

Page 7: ...te the BMS against protection Soft start When batteries suffer an over discharge the controller will softly ramp the battery voltage up to 10V Bulk Charge Maximum current charging until batteries rise to Absorption level Absorption Constant voltage charging and battery is over 85 for lead acid battery a Li ion battery LiFePO4 battery and LTO battery will close fully charging after absorption stage...

Page 8: ... FLASH OFF OFF OFF Normal Display ON Bulk charge charged capacity 25 ON ON FLASH OFF OFF OFF Bulk charge charged capacity 50 ON ON ON FLASH OFF OFF Bulk charge charged capacity 75 ON ON ON ON FLASH OFF Absorption charging ON ON ON ON ON FLASH Float charging ON OFF OFF OFF OFF ON Solar weak At dawn or dusk FLASH OFF Subject to battery voltage In the night OFF OFF OFF Solar good VB 5V ON OFF OFF OFF...

Page 9: ...ing timer timed out 4 Hour 2 7 Equalization charging active Only for WET or Calcium battery Battery voltage discharged to less than 10 0 2 VDC Automatic equalizing charging periodical 28 Day 2 8 Equalization charging voltage at 25 15 5 0 2 VDC 2 9 Equalization charging timer timed out 2 Hour 2 10 Float voltage GEL WET Calcium AGM battery at 25 13 8 0 2 VDC Restart voltage for LTO battery 13 2 0 2 ...

Page 10: ...1 All solar panels need to be connected to a battery to work 2 Make sure all Anderson connectors are plugged in 3 Make sure a wire has not been pulled out of the controller 4 Please ensure solar panel is connected directly to a battery Not through any secondary controller charger Note If reset of controller is needed remove all wires from battery Q Why am I not getting maximum amps per hour A Taki...