Float Charge or Re-Bulk charge

- Battery is fully charged and maintained at a safe level.

A fully charged Lead acid battery (GEL, AGM, WET and Calcium battery) has
a voltage of more than 13.8 Volts; if the lead acid battery voltage drops to
12.8V at float mode, it will return to Bulk charge; Li-ion,LiFePO4 and LTO
battery have no float mode; If a Li-ion battery voltage drops to 12.0V after
absorption stage, it will return to Bulk charge; if a LIFePO4 battery voltage
drops to 13.4V, or LTO battery voltage drops to 13.2V after Absorption stage,
they will return to Bulk charge

LED indications

LCD

Display

LCD

Backlight

LED Color

ORG

BLUE

BLUE

BLUE

BLUE

GREEN

White

Soft-start charging

ON

ON

FLASH

OFF

OFF

OFF

Normal

Display

ON

Bulk charge (charged

capacity < 25%)

ON

ON

FLASH

OFF

OFF

OFF

Bulk charge (charged

capacity < 50%)

ON

ON

ON

FLASH

OFF

OFF

Bulk charge (charged

capacity < 75%)

ON

ON

ON

ON

FLASH

OFF

Absorption charging

ON

ON

ON

ON

ON

FLASH

Float charging

ON

OFF

OFF

OFF

OFF

ON

Solar weak (At dawn or

dusk)

FLASH

OFF

Subject to battery voltage

In the night

OFF

OFF

OFF

Solar good, VB < 5V

ON

OFF

OFF

OFF

OFF

OFF

b03 / bLv

FLASH

Solar good, battery

reversed

ON

OFF

OFF

OFF

OFF

OFF

b02/ brc

FLASH

Solar good, battery

over-voltage

ON

OFF

FLASH

FLASH

FLASH

FLASH

b01 / bov

FLASH

Solar off, battery

over-voltage

OFF

OFF

FLASH

FLASH

FLASH

FLASH

b01 / bov

FLASH

Solar good, battery

over 65⁰C

ON

OFF

Subject to battery voltage

xxC/bot

FLASH

Battery good, solar

reverse

FLASH

OFF

P02/Prc

FLASH

Battery good, solar

over-voltage

FLASH

OFF

P01/Pov

FLASH

Over Temperature

Protection

xxC/Pot

FLASH

LED INDICATION

Summary of Contents for KOR12-10

Page 1: ...1 Solar Controller Battery Charger User s Manual ...

Page 2: ...ge provided you have satisfactory proof of purchase keep your receipt There are three standard versions of HARD KORR PWM controllers KOR12 10 Rated for 12V solar panel Max 25V Rated maximum output current of 10Amp KOR12 15 Rated for 12V solar panel Max 25V Rated for maximum output current of 15Amp KOR12 20 Rated for 12V solar panel Max 25V Rated for maximum output current of 20Amp RISK OF EXPLOSIV...

Page 3: ...Common negative grounding connection High efficiency and low power consumption Battery type setting and battery condition indication Smart charging control Charging time management LED indication for the battery condition and charging statues Digital display charging parameters and battery settings Automatically active to Lithium battery against BMS protection Thermal protection Over voltage prote...

Page 4: ...s 4 terminals which are clearly marked Solar and Battery There is a 12V and earth GND terminal for each circuit Refer to the wiring diagram as shown below please cover the solar panel before connecting cables WIRING CONNECTIONS ...

Page 5: ...start working automatically Please check your battery manufacturer s specifications to select correct battery type The unit provides 7 battery types for selections Lithium ion LiFePO4 LTO Gel AGM WET conventional lead acid and Calcium battery OPERATION LCD DISPLAY ...

Page 6: ...ct battery type setting may damage your battery When the controller powers on the unit will run self qualify mode and automatically show below items on LCD before going into charging process Self test starts digital meter segments test Software version test Rated voltage and current test External battery temperature sensor test if connected After going into charging process the LCD displays the ch...

Page 7: ...te the BMS against protection Soft start When batteries suffer an over discharge the controller will softly ramp the battery voltage up to 10V Bulk Charge Maximum current charging until batteries rise to Absorption level Absorption Constant voltage charging and battery is over 85 for lead acid battery a Li ion battery LiFePO4 battery and LTO battery will close fully charging after absorption stage...

Page 8: ... FLASH OFF OFF OFF Normal Display ON Bulk charge charged capacity 25 ON ON FLASH OFF OFF OFF Bulk charge charged capacity 50 ON ON ON FLASH OFF OFF Bulk charge charged capacity 75 ON ON ON ON FLASH OFF Absorption charging ON ON ON ON ON FLASH Float charging ON OFF OFF OFF OFF ON Solar weak At dawn or dusk FLASH OFF Subject to battery voltage In the night OFF OFF OFF Solar good VB 5V ON OFF OFF OFF...

Page 9: ...ing timer timed out 4 Hour 2 7 Equalization charging active Only for WET or Calcium battery Battery voltage discharged to less than 10 0 2 VDC Automatic equalizing charging periodical 28 Day 2 8 Equalization charging voltage at 25 15 5 0 2 VDC 2 9 Equalization charging timer timed out 2 Hour 2 10 Float voltage GEL WET Calcium AGM battery at 25 13 8 0 2 VDC Restart voltage for LTO battery 13 2 0 2 ...

Page 10: ...1 All solar panels need to be connected to a battery to work 2 Make sure all Anderson connectors are plugged in 3 Make sure a wire has not been pulled out of the controller 4 Please ensure solar panel is connected directly to a battery Not through any secondary controller charger Note If reset of controller is needed remove all wires from battery Q Why am I not getting maximum amps per hour A Taki...

Reviews: