background image

Read this material before using this product. 

Failure to do so can result in serious injury. 

SAVE THIS MANUAL.

Copyright

©

 2014 by Harbor Freight Tools

®

.  All rights reserved.  

No portion of this manual or any artwork contained herein may be reproduced in 

any shape or form without the express written consent of Harbor Freight Tools.  

Diagrams within this manual may not be drawn proportionally.  Due to continuing 

improvements, actual product may differ slightly from the product described herein.  

Tools required for assembly and service may not be included.

When unpacking, make sure that the product is intact 

and undamaged.  If any parts are missing or broken, 

please call 1-888-866-5797 as soon as possible.

Save This Manual

 

Keep this manual for the safety warnings and precautions, assembly, operating, 

inspection, maintenance and cleaning procedures.  Write the product’s serial number in the back of the manual 

near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and  

the receipt in a safe and dry place for future reference.

Owner’s Manual & Safety Instructions

Do not use for 

potable water.

Visit our website at: http://www.harborfreight.com

 Email our technical support at: [email protected]

ITEM 62508

REV 14l

Summary of Contents for PacificHydroStar

Page 1: ...e may not be included When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Save This Manual Keep this manual for the safety warnings and precautions assembly operating inspection maintenance and cleaning procedures Write the product s serial number in the back of the manual near the assembly diagram or m...

Page 2: ...and or di 2 ethylhexyl phthalate DEHP chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling California Health Safety Code 25249 5 et seq 11 WARNING This product contains lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm California Health Safety Code 25249 5 et seq...

Page 3: ...ecifications Electrical Rating 120VAC 60Hz 5A Inlet Outlet Diameter 1 NPT Maximum Pressure 50 PSI Maximum Flow 550 GPH Maximum Suction Lift 23 Maximum Delivery Height 110 Maximum Water Temperature 95 F 35 C Maximum Ambient Temperature 104 F 40 C Power Cord Length 6 3065430 ...

Page 4: ...Page 4 For technical questions please call 1 888 866 5797 Item 62508 Functions Inlet Outlet Priming Plug Power Cord not shown Figure A ...

Page 5: ...nresidential facility providing water for human consumption that is not lead free Power Supply 1 The pump is equipped with a shock proof plug according to regulations The pump is designed to be connected to 120 VAC 60 Hz safety socket 2 Make sure that the socket is sufficiently secured and is in excellent condition 3 When the plug is inserted into the socket the pump will be on standby WARNING If ...

Page 6: ...ncluded to help keep Pump primed 3 Remove strainer from Check Valve by turning it counterclockwise Figure B 4 Incorporate the following items into the plumbing See Figure D a check valve on inlet make sure it is positioned so water will flow in the proper direction Figure C b in line shutoff ball valves sold separately on inlet and outlet and c unions sold separately on inlet and outlet 5 Remove P...

Page 7: ...o the water supply with a 120V GFCI protected outlet nearby Note The Pump is not self priming A Check Valve is included to help keep Pump primed Figure E 2 Attach hoses to Inlet and Outlet 3 Attach Check Valve to Inlet hose 4 Place Inlet hose in water source 5 Remove Priming Plug fill cavity with water until water overflows Replace Priming Plug and tighten securely Inlet Hose Outlet Hose Inlet Out...

Page 8: ...socket is in good condition 5 Verify that water and moisture cannot get near the power supply socket 6 Verify that the pump is installed so as to prevent running dry General Operation 1 BEFORE EVERY USE make sure Impeller can move freely by inserting slotted screwdriver into center hole on Fan Cover and turning fan Figure G Fan Cover 2 Dry hands then plug Power Cord into a 120V GFCI protected outl...

Page 9: ...ng 1 Pump overheated 2 Fuse is blown or circuit breaker tripped 3 Voltage is too low 1 Wait for Pump to cool off restart pump MAKE SURE YOU DO NOT HAVE A DRIPPING FAUCET OR SLOW LEAK this will cause the pump to run continuously and overheat 2 Disconnect power and replace fuse or reset circuit breaker 3 Check voltage being supplied to pump Motor runs but no water is being delivered 1 Pipes are froz...

Page 10: ...loth 3 WHEN TAKING OUT OF SERVICE a Dry hands then unplug Pump b Close Inlet and Outlet Valves 4 TO PREVENT DAMAGE TO THE PUMP a If there is a possibility that it will be exposed to freezing temperatures Take out of service according to 3 above Disconnect pipes from pump Tip Pump to drain water b Do not expose the pump to freezing temperatures for an extended period Temporary Installation 1 BEFORE...

Page 11: ...r 1 15 Ball Bearing 2 16 Wave Spring 1 17 Fan Cover 1 18 Fan 1 19 Bolt M5 x 18 2 Item Description Qty 20 End Plate 1 21 Mechanical Bolt 2 22 Cord Clip 1 23 Gasket 1 24 Cord Clip 1 25 Wave Spring 1 26 Mechanical Bolt 1 27 Screw Cap 1 28 Seal Washer 1 29 Sealed Sheath 1 30 Cable 1 31 Mechanical Bolt 4 32 Capacitor Box 1 33 Sealing Ring 1 34 Cord Clip 3 35 Capacitor 1 36 Stator 1 37 Priming Plug 1 38...

Page 12: ...tion of the complaint must accompany the merchandise If our inspection verifies the defect we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement We will return repaired products at our expense but if we determine there is no defect or that the defect resulted from causes not within t...

Reviews: