Installation

WARNING!  TO PREVENT SERIOUS INJURY:  

Verify that installation surface has no hidden 

utility lines before installing light fixtures.

1.  Place Power Pack close to GFCI outlet.  It 

must receive maximum sunlight in order 

for photo sensor to work properly.  

2.  Lay Power Pack on its back on a sturdy surface.   

Do not plug in Power Pack.

3. 

Connect Wires to Power Pack

a.  Split conductors 2

, strip 3/4

 of 

insulation, twist strands together.

b.  Loosen screws.  Insert each conductor 

under one screw.  Screw connections must 

be tight.  Do not mix solid and stranded 

type wires under one screw.  Make sure 

insulation clears Pressure Plate.

4. 

Mount Power Pack

WARNING!  TO PREVENT SERIOUS INJURY:  

Verify that installation surface has no hidden 

utility lines before drilling or driving screws.

a.  Using included template, mark 

and drill mounting holes.

b.  Insert two included anchors into the holes 

and two included screws into the anchors 

leaving about 1/4

 of threads exposed.

c.  Place large center of keyholes on back of Power 

Pack over screw heads and pull down gently to 

lock screws into keyholes.   

Do not plug in Power Pack.

5. 

Install Light Fixtures

a.  Lay out light fixtures in desired locations.  

The first light fixture must be installed 

at least 10 feet from Power Pack.  

b.  Lay out Landscape Wire from Power Pack 

along path of light fixtures.  

c.  Install light fixtures, then connect to wire 

according to light fixture’s instructions.  

d.  Bury wire no deeper than 6".  

6.  Plug in Power Cord.  

Do not use 

an extension cord.

7.  Press Up/Down buttons to scroll through menu.

a. 

= Auto - Dusk to dawn.

b. 

1 -9 

= Hours on after dusk.

c. 

O = 

Manual - On until manually turned off.

Summary of Contents for 57998

Page 1: ...ce for future reference 21e When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2020 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams...

Page 2: ...not connect two or more power supplies together 7 Do not use extension cords 8 For use with low voltage landscape lighting systems only 9 Use only with maximum 120W lamp load 10 Mount the power unit in or on non combustible mounting surfaces only 11 Main secondary wiring is intended for shallow burial less than 6 inches 152mm 12 Not suitable for use with submersible luminaries and pumps 13 Do not ...

Page 3: ...ON Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded Do not modify the power cord plug provided Never remove the grounding prong from the plug Do not use the power unit if the power cord or plug is damaged If damaged have it repaired by a service facility before use If the plug will not fit the outlet have a proper outlet installed by a qualified ...

Page 4: ...r unit connected to the receptacle If one is not provided contact a qualified electrician for proper installation Ensure that the power unit and cord do not interfere with completely closing the receptacle cover Do not plug in Power Cord until installation is complete Landscape Wire Selection This data is provided as a general guideline 12 VOLT TAP Wire Length Total Fixture Wattage 0 50 feet 51 10...

Page 5: ...Verify that installation surface has no hidden utility lines before drilling or driving screws a Using included template mark and drill mounting holes b Insert two included anchors into the holes and two included screws into the anchors leaving about 1 4 of threads exposed c Place large center of keyholes on back of Power Pack over screw heads and pull down gently to lock screws into keyholes Do n...

Page 6: ...vice technician Troubleshooting Problem Possible Causes Probable Solutions Lights will not turn on 1 No power 2 Bad connection at Power Pack 3 Short in landscape wire 4 Power Pack overloaded 5 Circuit overloaded 1 Check that Power Pack is connected to 120VAC GFCI outlet 2 Check for loose connection at screw terminal 3 Replace shorted wire with 16 2 16AWG 2 Conductor Low Voltage Landscape wire 4 Re...

Page 7: ...ns please call 1 888 866 5797 Item 57998 Record Serial Number Here Note If product has no serial number record month and year of purchase instead Note Replacement parts are not available for this product Refer to UPC 193175430588 ...

Page 8: ...lusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an expl...