background image

7

ASSEMBLY INSTRUCTIONS

7a.

Hardware Used

             Wire Connector                               x 3 

Unwrap BARE wire from BLACK and 
WHITE wires on back of fixture (A). 
Prepare wire by stripping 1/2 inch of 
insulation from wire ends using wire 
strippers (not included). 

Connect BARE/GREEN ground wire from 
outlet box to BARE ground wire from fixture 
(A) using wire connector (AA). Connect 
WHITE wire from fixture (A) to WHITE wire 
from outlet box using existing wire 
connector or wire connector (AA). Connect 
BLACK wire from fixture (A) to BLACK wire 
from outlet box using existing wire 
connector or wire connector (AA).   

NOTE:

 Screw wire connectors (AA) on in a 

clockwise direction.

      

WARNING:

 Never connect ground wire 

to WHITE or BLACK power supply wires.

      

WARNING: 

To reduce the risk of fire, 

electrical shock, or personal injury, wire 
connectors (AA) provided with this light 
fixture are designed to accept only one 
12-gauge house wire and two lead wires 
from the light fixture. If your house wire is 
larger than 12-gauge or there is more than 
one house wire to connect to the 
corresponding fixture lead wires, consult an 
electrician for the proper size wire 
connectors to use.

AA

7b.

4

4

7a

7b

Outlet Box

WHITE

WHITE

BLACK

BARE/

GREEN

BLACK

 AA

 AA

 AA

BARE

Summary of Contents for WL136MW

Page 1: ...o design are trademarks or registered trademarks of LF LLC All rights reserved VR21099 Questions problems missing parts Before returning to your retailer call our customer service department at 1 888...

Page 2: ...tenance 10 Troubleshooting 10 Warranty 10 TABLE OF CONTENTS 2 A Fixture 1 B Mounting Strap 1 C Decorative Nut preassembled to 2 screw D D Screw preassembled to mounting 2 strap B E Nut preassembled to...

Page 3: ...subject to electrical shock which could cause serious injury or death DO NOT connect the bare or green insulation fixture ground wire to the black HOT current carrying wire or the white NEUTRAL house...

Page 4: ...install fixture at least 4 ft above the ground floor Before beginning assembly of product make sure all parts are present Compare parts with package contents list and hardware contents list If any pa...

Page 5: ...supply line leads DANGER Failure to disconnect power supply prior to installation may result in serious injury or death 1 Remove existing fixture and disconnect all electrical wiring 1 2 Remove two de...

Page 6: ...p B so the screws D are level horizontally Use a level not included to adjust screws D parallel with floor and ceiling as needed Tighten preassembled set screw located in the middle of the mounting st...

Page 7: ...re from outlet box using existing wire connector or wire connector AA NOTE Screw wire connectors AA on in a clockwise direction WARNING Never connect ground wire to WHITE or BLACK power supply wires W...

Page 8: ...n to the wire WARNING Make sure no bare wire or wire strands are visible after making connections Push wire connectors AA gently into outlet box Carefully push excess wiring into outlet box 9 Align ho...

Page 9: ...unting surface with silicone weather sealant not included WARNING Failure to caulk fixture mounting surface with silicone weather sealant may result in water damage in outlet box which may cause elect...

Page 10: ...y for direct incidental or consequential damages improper packaging of returned products and acts of God As some states do not allow exclusions of limitations on an implied warranty the above exclusio...

Reviews: