background image

14

TROUBLESHOOTING

Fan sounds 
noisy.

 

 

Fan wobbles.

Light does 
not work.

 

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

1. Hex nuts are loose.

        

Fan does 
not start.

2. Normal noise.

3. Wire connectors inside switch 
    housing rattling.

4. Cracked blade. 

5. Faulty light bulb installation.

6. Glass is not secure.

1. Tighten all hex nuts with wrench securely.

2. Allow "break-in" period of 24 hours. Most noises 
    associated with a new fan will disappear after this period. 

3. Check to make sure wire connectors in switch housing 
    are not rattling against each other or against the interior 
    wall of the switch housing.

4. Replace blades.

5. Check to be sure light bulb is tight in socket and not 
    touching glass shade.

6. Secure the glass.

3. Blades are loose.
4. Blade holders incorrectly attached 
    and loose.

5. Fan blade out of balance.

6. Wobble appears when changing fan
    speed.

3. Check that all blades are screwed firmly into blade holders.

1. Hanger bracket and/or ceiling outlet
    box is not securely fastened.

1. Tighten the hanger bracket screws to the outlet box, and/or 
    secure outlet box.

2. Hex nuts are loose.

2. Tighten all hex nuts with wrench securely.

4. Check to be sure the fan blade flanges sit firmly and 
    uniformly to the surface of the motor hub. If flanges are 
    seated incorrectly, loosen the flange screws and retighten.

5. If blade wobble is still noticeable, interchanging two 
    adjacent (side by side) blades can redistribute the weight 
    and possibly result in smoother operation, or you can use 
    supplied balancing kit to balance blades.

6. When switching from medium to low speed, you may 
    notice some fan wobble. When the fan stabilizes at low 
    speed, wobble will disappear.

1. Power turned off, fuse blown, or 
    circuit breaker tripped.
2. Loose wire connections or wrong 
    connections.

3. Motor reversing switch not engaged.

4. Pull chain switch not "on".

1. Turn power on, replace fuse, or reset breaker.

2a. Turn power off and loosen motor housing, check all 
      connections according to section "WIRING 
      INSTRUCTIONS".
2b. Check the plug connection in the switch housing. 
3. Push switch firmly right or left (up or down). Fan will not 
    operate when switch is in the middle.
4. Pull switch chain.

1a. Wrong wire connection.

1a. Refer to Step 1, page 8 to ensure all wire connections 
      were done correctly. 

1b. Bulb is burned out.

1b. Replace the bulbs.

Summary of Contents for L1901

Page 1: ...rk of LF LLC All Rights Reserved 1 Español p 17 Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 6 p m EST Monday Thursday p m EST Friday ATTACH YOUR RECEIPT HERE Serial Number Purchase Date PH19238 8 a m 5 ...

Page 2: ...Instructions Wiring Instructions Final Installation Instructions Operation Instructions Care and Maintenance Troubleshooting Limited Lifetime Warranty Replacement Part List Safety Information 4 Package Contents Hardware Contents 3 4 5 6 8 9 13 13 14 15 16 ...

Page 3: ...g Bracket A Mounting Screw Preassembled on Switch Housing Plate C Light Kit Mounting Screw Preassembled on Switch Housing G Silicone Washer Preassembled on Light Kit H Metal Washer Preassembled on Light Kit H Manual Nut Preassembled on Light Kit H Finial Finial Cap Motor Housing 5 5 1 F G E Switch Housing Blade Blade Iron 1 1 I H Glass Bowl Light Kit 2 J 1 K 1 L 4 M Bulb A B C D E H G F I N M O P ...

Page 4: ...and electrical rating required The lighting fixture must be positioned so there is at least 1 64 ft between the bulb and any illuminated surface For supply connections if the conductor of a fan is identified as a grounded conductor then it should be connected to a grounded conductor power supply If the conductor of a fan is identified as an ungrounded conductor then it should be connected to an un...

Page 5: ...5 WARNING CAUTION PREPARATION Estimated Assembly Time and Wrench ...

Page 6: ...rn off circuit breakers and wall switch to the fan supply line leads installation may result in serious injury or death or T Turn Off Power Source 3 Check existing outlet box not included to ensure it is securely fastened to at least two points in a structural ceiling member and can support the full weight of the fan Once verified install mounting bracket A to the outlet box using the screws and w...

Page 7: ...nuts M and metal washers N from the threaded rods on the mounting bracket A Hang the motor body B onto the hook from the mounting bracket A This will allow for hands free wiring INITIAL INSTALLATION INSTRUCTIONS A N M B 4 ...

Page 8: ...turn wires upward and carefully push them into the outlet box make sure the WHITE and GREEN connections are on one side and the BLACK connections are on the other side WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before hanging WARNING If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be groun...

Page 9: ... dot labels on the motor housing D with the mounting bracket A place the mounting bracket A onto the recesses on the motor housing D properly then rotate the motor housing D clockwise until the mounting bracket A slide into the slot hole inside the motor housing D 9 FINAL INSTALLATION INSTRUCTIONS Motor Bracket Recesses Recesses dot label A A A D B N M 1 1 2 3 Position blade iron E under blade F S...

Page 10: ...from the switch housing G onto the two protruding screw heads on the mounting plate C Twist the switch housing G until the screw heads engage the keyslots Install mounting screws O into the closed hole in the switch housing G Tighten all mounting screws O to complete attachment of the switch housing G Hardware Used x 10 CC Motor Screw 6 Remove the three screws P preinstalled on the switch housing ...

Page 11: ...olding the glass bowl I guide the pull chains through the appropriate holes on the bottom of the glass bowl I Place the silicone washer Q metal washer R and the manual nut S onto the rod and tighten securely Guide the pull chains through the appropriate holes on the finial cap K Attach the finial cap K to the glass bowl I and tighten them using the finial L 7 Install the two bulbs J into each sock...

Page 12: ...ull once for each position 2 The fob DD marked with a lamp image controls the light either On or Off with each pull of the chain WARNING Please do not change to wall control or remote control 2 DD 1 DD 9 DD 9 Connect the fobs DD to the appropriate pull chains Hardware Used x 2 DD Fob FINAL INSTALLATION INSTRUCTIONS ...

Page 13: ... 5 5 watt max type A 15 LED bulbs CFL bulbs are not recommended for this item At least twice each year tighten all screws and lower canopy motor housing to check mounting bracket screws and hex nuts Clean fan housing with only a soft brush or lint free cloth to avoid scratching the finish Clean blades with a lint free cloth You may occasionally apply a light coat of furniture polish to wood blades...

Page 14: ...e outlet box 2 Hex nuts are loose 2 Tighten all hex nuts with wrench securely 4 Check to be sure the fan blade flanges sit firmly and uniformly to the surface of the motor hub If flanges are seated incorrectly loosen the flange screws and retighten 5 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operat...

Page 15: ...pitting tarnishing corroding or peeling Brass finish fans maintain their beauty when protected from varying weather conditions Any glass provided with this fan is not covered by the warranty Any replacement of defective parts for the ceiling fan must be reported within the first year from the date of purchase For the balance of the warranty call our customer service department at 1 800 643 0067 fo...

Page 16: ...ay 8 a m 5 p m EST Friday A Mounting Bracket A102 0374005 D Motor Housing A113 0375490 E Blade Iron A143 0193490 F Blade A141 0244036 G Switch Housing A121 0143005 H Light Kit A187 0225036 I Glass Bowl A182 0230001 K Finial Cap A183 0031490 L Finial A186 0109490 AA Wire Nut Blade Screw Motor Screw Fob BB CC DD B168 0598005 Part Description Part Printed in China ...

Reviews: