background image

18

Lowes.com/harborbreeze

CARE AND MAINTENANCE

At least twice each year, lower the canopy to check the downrod assembly, and then tighten all 

screws on the fan . Clean the motor housing with only a soft brush or lint-free cloth to avoid scratching 

the finish. Clean the blades with a lint-free cloth. You may occasionally apply a light coat of furniture 

polish to wood blades for added protection . 

Bulb Replacement: Use 13-watt max . GU24 bi-pin base CFL bulbs .

Impootaat:

 Shut off the main power supply before you begin any maintenance tasks . Do not use 

water or a damp cloth to clean the ceiling fan .

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

The fan does not 

move .

1 .  The power is off or the fuse is 

blown .

2 .  There is a faulty wire connection .

3 .  The plugs are not connected 

properly .

4 .  The DC motor is obstructed 

during operation .

5 .  The power of the motor is over 

80W .

1 .  Turn the power on or check the 

fuse .

2 .  Turn the power off . Loosen 

the canopy and check all 

connections .

3 .  Check that the connectors from 

the light kit fitter and fan are 

connected properly .

4 .  Disable the power supply to the 

fan motor and re-start the motor .

5 .  The blade is overweight . Do not 

install the unapproved blades .

The fan is noisy .

1 .  The blades are loose . 

 

2 .  There is a cracked blade .
3 .  The wall control is not compatible 

with the fan .

4 .  The break-in period has not 

surpassed . 

5 .  The outlet box is not secure . 

6 .  The mounting bracket is not 

secure .

1 .  Check and tighten all screws 

that hold the fan blades to the 

blade arms and the motor .

2 .  Replace the cracked blade .
3 .  Do not use a full range dimmer 

switch to control the fan speed .

4 .  Run the fan continuously for 24 

- 48 hours on medium or high 

speed for a break-in period .

5 .  Ensure the outlet box is secured 

to the building structure .

6 .  Ensure the mounting bracket is 

secured to the outlet box and 

that the screws are tight .

Summary of Contents for KINGSBURY 40190

Page 1: ...8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday 1 Lowes com harborbreeze Harbor Breeze is a registered trademark of LF LLC All Rights Reserved ATTACH YOUR RECEIPT HERE Serial Number ___________...

Page 2: ...ge Contents 3 Hardware Contents 4 Safety Information 5 Preparation 6 Initial Installation 7 Wiring 13 Final Installation 14 Operating Instructions 17 Care and Maintenance 18 Troubleshooting 18 Limited...

Page 3: ...A Downrod 1 B Canopy preassembled to Mounting Bracket C 1 C Mounting Bracket 1 D Light Kit Fitter 1 E Motor Assembly 1 F Yoke Cover 1 G Blade Arm 5 H Blade 5 I Glass Shade 1 J Bulb 2 K Canopy Cover pr...

Page 4: ...to Downrod A Downrod Clip Qty 1 preassembled to Downrod A Motor Housing Set Screw Qty 2 preassembled to Motor Assembly E Mounting Bracket Screw Qty 4 preassembled to Mounting Bracket C Fitter Plate S...

Page 5: ...a full range dimmer switch to control the fan speed WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an outlet box marked ACCEPTABLE FOR FAN SUPPORT and use the m...

Page 6: ...this product ensure that all parts are present Compare all parts with the package contents list and hardware contents list If any part is missing or damaged do not attempt to assemble the product Aft...

Page 7: ...Determine the mounting method to use Note Flushmount installation is not available for this item Important If using the angle mount check to ensure the ceiling angle is not steeper than 23 2 Downrod M...

Page 8: ...screws and washers provided with the outlet box Note It is very important you use the proper hardware when installing the mounting bracket C as this will support the fan Important If using the angle m...

Page 9: ...ted for ceilings 8 ft or higher For taller ceilings you may want to use a longer downrod not included Angle mounting is best suited for angled or vaulted ceilings A longer downrod is sometimes necessa...

Page 10: ...r assembly E Hardware Used EE Downrod Pin x 1 FF Downrod Clip x 1 GG Motor Housing Set Screw x 2 F E FF GG A EE 3 4 Depending on the length of downrod you use you may need to cut the lead wires back t...

Page 11: ...p for black and green wires Note If you did not cut back the lead wires in Step 4 Step 5 is not necessary and you may proceed to Step 6 instead 5 6 Install the ball end of the downrod A into the openi...

Page 12: ...ft high The downrod hanging ball and canopy cover are not used in this type of installation 1 K B 2 Align the canopy B with the holes in the top of the motor assembly E Reinstall the closemount screws...

Page 13: ...these steps Connect the Green wires from the fan and the mounting bracket C to the Bare Green ground supply wire Connect the White wire from the fan to the White supply wire Connect the Black wire fro...

Page 14: ...INAL INSTALLATION 1 Align the canopy B over the loose mounting bracket screws HH preassembled on mounting bracket C Place the keyholes of the canopy B onto the mounting bracket screws HH and rotate th...

Page 15: ...G through slots in the side of the motor assembly E Align the holes of one blade arm G with two motor screw holes in underside of the motor assembly E Secure with two motor screws AA Repeat this step...

Page 16: ...holes of the light kit fitter D with the loosened light plate screws JJ and replace previously removed lit kit plate screw JJ Tighten all screws Hardware Used JJ Light Kit Plate Screw x 3 D JJ E L 6 7...

Page 17: ...rom room Season Slide Switch Changes direction of blade rotation For warm weather slide switch to the left and for cool weather slide switch to the right 2 Remove battery door from back of the remote...

Page 18: ...ring operation 5 The power of the motor is over 80W 1 Turn the power on or check the fuse 2 Turn the power off Loosen the canopy and check all connections 3 Check that the connectors from the light ki...

Page 19: ...o the electrical outlet box The bracket must be flush without movement against the outlet box 4 Use a longer downrod or move the fan to another location 5 Lift up the yoke cover and tighten the set sc...

Page 20: ...te control see p 17 4 The remote control has been synced to this fan at the factory and the dip switch as been switched to 0 inside the battery compartment If you have more than one remote control in...

Page 21: ...alid Due to varying climate conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest...

Page 22: ...0067 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday PART DESCRIPTION PART A Downrod 184428 A B Canopy 184428 B C Mounting Bracket 184428 C D Light Kit Fitter 184428 D F Yoke Cover 184428 F G...

Page 23: ...a nuestro Departamento de Servicio al Cliente al 1 800 643 0067 de lunes a jueves de 8 a m a 6 p m hora est ndar del Este y los viernes de 8 a m a 5 p m hora est ndar del Este ADJUNTE SU RECIBO AQU N...

Page 24: ...amentos 26 Informaci n de seguridad 27 Preparaci n 28 Instalaci n inicial 29 Cableado 35 Instalaci n final 36 Instrucciones de funcionamiento 39 Cuidado y mantenimiento 40 Soluci n de problemas 40 Gar...

Page 25: ...adera de montaje C 1 C Abrazadera de montaje 1 D Soporte del kit de iluminaci n 1 E Ensamblaje del motor 1 F Cubierta de la horquilla 1 G Brazo del aspa 5 H Aspa 5 I Pantalla de vidrio 1 J Bombilla 2...

Page 26: ...ant 1 preensamblado en la varilla A Tornillo de ajuste de la carcasa del motor Cant 2 preensamblado en el ensamblaje del motor E Tornillo de la abrazadera de montaje Cant 4 preensamblado en la abrazad...

Page 27: ...rolar la velocidad del ventilador ADVERTENCIA Para reducir el riesgo de incendios descargas el ctricas o lesiones personales instale el ventilador en una caja de salida marcada como ACCEPTABLE FOR FAN...

Page 28: ...rme a la Secci n 15 de las reglas de la FCC Estas normas se dise aron para proporcionar una protecci n razonable contra la interferencia perjudicial en una instalaci n residencial Este equipo genera u...

Page 29: ...Determine el m todo de instalaci n que utilizar Note La instalaci n de montaje al ras no est disponible para este art culo Important Si realiza el montaje en ngulo verifique que el ngulo del techo no...

Page 30: ...s arandelas planas que se proporcionan con la caja de salida Note Es muy importante que use los aditamentos adecuados para instalar la abrazadera de montaje C ya que esta soportar el ventilador Import...

Page 31: ...to o de mayor altura Para techos m s altos se recomienda utilizar una varilla m s larga no incluida El montaje en ngulo es mejor para los techos en ngulo o de b veda En ocasiones es necesaria una vari...

Page 32: ...del motor E Aditamentos utilizados EE Pasador de la varilla x 1 FF Sujetador de la varilla x 1 GG Tornillo de ajuste de la carcasa del motor x 2 F E FF GG A EE 3 4 Seg n el largo de la varilla A que...

Page 33: ...e y negro Nota Si no cort los cables conductores en el paso 4 el paso 5 no es necesario y puede continuar con el paso 6 en su lugar 5 6 Instale el extremo con la bola de la varilla A en la abertura de...

Page 34: ...la para colgar y la cubierta de la base no se utilizan en este tipo de instalaci n 1 K B 2 Alinee la base B con los orificios de la parte superior del ensamblaje del motor E Fije la base B a la parte...

Page 35: ...endo estos pasos Conecte los conductores verdes del ventilador y de la abrazadera de montaje C al conductor de suministro desnudo verde de puesta a tierra Conecte el conductor blanco del ventilador al...

Page 36: ...cios de la base B con la cabeza de los tornillos de la abrazadera de montaje HH preinstalados en la abrazadera de montaje C Levante la base B y g rela en direcci n de las manecillas del reloj hasta qu...

Page 37: ...spa G con los dos orificios del ensamblaje del motor E y f jelos con dos tornillos del motor AA mediante un destornillador Phillips Repita este procedimiento con los brazos de aspa restantes G Aditame...

Page 38: ...ltos de la placa de iluminaci n JJ y reemplace y apriete todos los tornillos de la placa del kit de iluminaci n JJ Aditamentos utilizados JJ Tornillo de la placa del kit de iluminaci n x 3 D JJ E L 6...

Page 39: ...da Cambia la direcci n de giro de las aspas En climas c lidos deslice el interruptor a la izquierda y en climas fr os deslice el interruptor a la derecha 2 Retire la puerta de la bater a de la parte p...

Page 40: ...perior a los 80 vatios 1 Encienda el suministro de electricidad o verifique el fusible 2 Interrumpa el suministro de electricidad Afloje la base y revise todas las conexiones 3 Verifique que los conec...

Page 41: ...salida y no debe moverse 4 Utilice una varilla m s larga o mueva el ventilador a otra ubicaci n 5 Levante la cubierta de horquilla y apriete el tornillo de ajuste en la horquilla hasta que quede firm...

Page 42: ...o de la bater a del control remoto consulte la p gina 39 4 El control remoto ha sido sincronizado con este ventilador en la f brica y el interruptor DIP se ha puesto en 0 dentro del compartimiento de...

Page 43: ...garant a Debido a las cambiantes condiciones clim ticas esta garant a no cubre cambios en el acabado de lat n incluidos la oxidaci n las picaduras la corrosi n el deslustre o el descascarado Los acab...

Page 44: ...EZA A Varilla 184428 A B Base 184428 B C Abrazadera de montaje 184428 C D Soporte del kit de iluminaci n 184428 D F Cubierta de la horquilla 184428 F G Brazo del aspa 184428 G H Aspa 184428 H I Pantal...

Reviews: