background image

8

WIRING

 1. 

Wire Connector                                       x 3

Hardware Used

AA

Make the necessary wiring connections for 
remote control operation as detailed below and 
in the figure. For each wire connection, use one 
of the wire connectors (AA), (L), making sure to 
screw wire connector on in a clockwise 
direction.

CAUTION:

 Assistance from another person is 

recommended for this step.

Connect all GROUND (GREEN) wires together 
from fan and mounting plate (A) to 
BARE/GREEN supply wire from ceiling.

Connect BLACK wire (labeled AC IN L) from 
remote control receiver (M) to BLACK supply 
wire from ceiling.

Connect WHITE wire (labeled AC IN N) from 
remote control receiver (M) to WHITE supply 
wire from ceiling.

Connect WHITE wire (labeled TO MOTOR N) 
from remote control receiver (M) to WHITE wire 
from motor housing (D).

Connect BLACK wire (labeled TO MOTOR L) 
from remote control receiver (M) to BLACK wire 
from motor housing (D).

Connect BLUE wire (labeled FOR LIGHT) from 
remote control receiver (M) to BLUE wire from 
motor housing (D).

Wrap electrical tape around each individual wire 
connector (AA), (L) down to the wire.

      

WARNING:

 Make sure no bare wire or wire 

strands are visible after making connections. 
Place green and white connections on opposite 
side of box from the black and blue (if applicable) 
connections.

Turn spliced/taped wires upward and gently push 
wires and wire connectors into outlet box.

 2. 

2

AA

AA

AA

M

1

WHITE SUPPLY WIRE

BLACK SUPPLY WIRE

BLACK

BLACK

WHITE

BLUE

BLUE

WHITE

BLACK

AC IN L

WHITE

AC IN N

WHITE

GROUND (GREEN OR BARE)

GROUND 

(GREEN OR BARE)

BLACK

FROM

RECEIVER

FROM 

FAN

FROM

RECEIVER

FROM

CEILING

Summary of Contents for FWH60BNK3LRS

Page 1: ...60BNK3LRS Purchase Date 1 Espa ol p 18 APPROVED FOR USE IN DAMP LOCATIONS ATTACH YOUR RECEIPT HERE Questions problems missing parts Before returning to your retailer call our customer service departme...

Page 2: ...ng the blades SAFETY INFORMATION READ AND SAVE THESE INSTRUCTIONS Do not discard fan carton or foam inserts Should this fan need to be returned to the factory for repairs it must be shipped in its ori...

Page 3: ...ne house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use To reduce the risk of fire or electrical shock do not use the fan with an...

Page 4: ...crew Washer 4 preassembled C Ring 1 D Motor Housing 1 E Motor Plate Screw 3 preassembled F Fitter Plate 1 DESCRIPTION PART QUANTITY PACKAGE CONTENTS 4 DESCRIPTION PART QUANTITY G LED Light Kit 1 H Sha...

Page 5: ...Assembly Time 120 minutes Tools Required for Assembly not included Electrical Tape Phillips Screwdriver Pliers Safety Glasses Stepladder and Wire Strippers Helpful Tools not included AC Tester Light T...

Page 6: ...n outer edge of mounting plate A directly opposite the one was just removed Partially loosen the other two mounting plate screw washers B Save mounting plate screw washers B for later use 3 Secure mou...

Page 7: ...gauge house wire and two lead wires from the fan If your house wire is larger than 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician...

Page 8: ...labeled TO MOTOR N from remote control receiver M to WHITE wire from motor housing D Connect BLACK wire labeled TO MOTOR L from remote control receiver M to BLACK wire from motor housing D Connect BLU...

Page 9: ...th this fan it must also meet these same requirements 1 FINAL INSTALLATION Raise ring C and align tabs on ring C with grooves on motor housing D until you hear tabs snap into grooves NOTE Ring C shoul...

Page 10: ...underside of the motor housing D Tighten both motor screws washers BB Repeat for the other two blades I NOTE Make sure all blades I are completely secure before proceeding 10 Hardware Used Blade Scre...

Page 11: ...e F to ensure wires do not get pinched when attaching the LED light kit G Align slotted holes in LED light kit G with loosened fitter plate screws K on fitter plate F Twist light LED light kit G to lo...

Page 12: ...ed installation site The remote control transmitter from remote pack L rests inside the bracket 9 Align slots on shade H with protrusions on underside of fitter plate F Turn shade H clockwise until it...

Page 13: ...user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Con...

Page 14: ...periods Store the remote control transmitter away from excess heat or humidity 2 Remote Control Transmitter OPERATING INSTRUCTIONS Operation buttons on the panel of the remote control transmitter 3 bu...

Page 15: ...weather setting the reverse switch in the RIGHT position will result in upward airflow that can help move stagnant hot air off the ceiling area 4 Use the fan reverse switch located on the motor housin...

Page 16: ...ll connections Noisy operation 1 Blades are loose 2 Cracked blade 3 Motor housing is loose 4 Fan is new 1 Tighten all motor screw washers BB 2 Replace blade I 3 Verify mounting plate screw washers B a...