TROUBLESHOOTING
16
Lowes.com/harborbreeze
Fan Wobbles.
8. Fan too close to vaulted
ceiling.
8. Lower or move fan. Extension downrods
may be ordered.
9. Transition to different speed. 9. When switching from medium to low speed,
you may notice some fan wobble in the fan.
When the fan stabilizes at low speed, wobble
should disappear.
10. Fan not securely mounted. 10. Make sure canopy and mounting bracket
are tightened securely to ceiling joist.
1. Power turned off, fuse blown
or circuit breaker tripped.
1. Turn power on, replace fuse or reset breaker.
3. Motor reversing switch not
engaged.
3. Push switch firmly right or left. Fan will not
operate when switch is in the middle.
4. Pull chain switch not "on". 4. Pull switch chain.
1. Wrong wire connection.
1. Refer to Step 1, page 10 to ensure all wire
connections were done correctly.
2. Bulb is burned out.
2. Replace the bulbs.
Light does not work.
Fan does not start
2b. Check the plug connection in the switch
housing.
2a. Turn power off and loosen canopy; check
all connections according to section WIRING
INSTRUCTIONS on page 10.
2. Loose wire connections or
wrong connections.
PROBLEM
PROBABLE CAUSE
CORRECTIVE ACTION
.
6. Blade holders are loose.
6. Check to be sure the fan blade irons seat
firmly and uniformly on the surface of the motor.
If flanges are seated incorrectly, loosen the
flange screws and retighten.
7. Blade out of balance.
7. Interchange two adjacent blades; this will
redistribute the weight and possibly result in
smoother operation. Or, refer to the instructions
inside the balance kit (Q).