SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install the 

product.
• 

Before you begin installing the fan, disconnect the power by removing fuses or turning off the circuit 

breakers.

•  Make sure all electrical connections comply with local codes, ordinances, the National Electrical 

Code and ANSI/NFPA 70-199. Hire a qualified electrician or consult a do-it-yourself wiring 

handbook if you are unfamiliar with installing electrical wiring.

•  Make sure the installation site you choose allows a minimum clearance of 7 ft. from the blades to 

the floor and at least 30 in. from the end of the blades to any obstruction.

•  The net weight of this fan is: 26.03 lb (11,81 kg).

DANGER:

 When using an existing outlet box, make sure the outlet box is securely attached to 

the building structure and can support the full weight of the fan. Failure to do this can result in serious 

injury or death. The stability of the outlet box is essential in minimizing wobble and noise in the fan 

after installation is complete.

WARNING:

 To avoid personal injury, the use of gloves may be necessary while handling fan 

parts with sharp edges.

WARNING:

 Using a full-range dimmer switch to control fan speed will cause a loud humming 

noise from the fan. To reduce the risk of fire or electric shock, do NOT use this fan with any solid-state 

speed control device.

WARNING: 

To reduce the risk of fire, electric shock or personal injury, mount the fan to an outlet 

box marked “ACCEPTABLE FOR FAN SUPPORT” and use the mounting screws provided with the 

outlet box. Most outlet boxes commonly used for the support of lighting fixtures are not acceptable 

for fan support and may need to be replaced. Consult a qualified electrician if in doubt. Secure the 

outlet box directly to the building structure. The outlet box and its support must be able to support the 

moving weight of the fan (at least 35 lbs.). 

WARNING: 

To reduce the risk of fire, electric shock or personal injury, wire connectors provided 

with this fan are designed to accept only one12-gauge house wire and two lead wires from the fan. If 

your house wire is larger than 12-gauge and/or there is more than one house wire to connect to the 

two fan lead wires, consult an electrician for the proper size wire connectors to use.

WARNING: 

To reduce the risk of fire, electric shock or personal injury, do not bend the blade 

arms when installing them, balancing the blades or cleaning the fan. Do not insert objects between 

the rotating fan blades.

WARNING: 

To reduce the risk of personal injury, use only parts provided with this fan. The use 

of parts OTHER than those provided with this fan will void the warranty.

Summary of Contents for 42612

Page 1: ...ase Date _________________________ ITEM 4904932 4904931 CUMBERLAND XL CEILING FAN MODEL 42612 42613 AS21776 Questions problems missing parts Before returning to your retailer call our customer service department at 1 888 251 1003 8 a m 8 p m EST Monday Sunday You could also contact us at partsplus lowes com Español p 20 2hr 4hr 8hr ...

Page 2: ... 4 Safety Information 5 Preparation 6 Initial Installation 7 Standard or Angle Mounting Instructions 9 Wiring 11 Final Installation 12 Operating Instructions 15 Care and Maintenance 16 Troubleshooting 16 Limited Lifetime Warranty 18 Replacement Parts List 19 ...

Page 3: ...y E 1 G Yoke Cover 1 H Motor Assembly 1 I Set Screw preassembled to the Motor Assembly H 2 J Mounting Bracket Screw preassembled to the Mounting Bracket D 4 K Fitter Plate preassembled to the Motor Assembly H 1 L Fitter Plate Screw preassembled to the Fitter Plate K 4 M Light Pan 1 N Light Pan Screw preassembled to the Light Pan M 3 O Light Kit 1 P Remote Pack 1 Q Glass Bowl 1 R Medallion 6 S Blad...

Page 4: ...4 HARDWARE CONTENTS Wire Connector Qty 3 1 extra Blade Screw Qty 18 1 extra Blade Washer Qty 18 1 extra Motor Screw Qty 12 1 extra XX shown actual size AA BB CC ...

Page 5: ...use a loud humming noise from the fan To reduce the risk of fire or electric shock do NOT use this fan with any solid state speed control device WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an outlet box marked ACCEPTABLE FOR FAN SUPPORT and use the mounting screws provided with the outlet box Most outlet boxes commonly used for the support of lighting fixt...

Page 6: ... interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receive...

Page 7: ...included Angle Mounting is best suited for angled or vaulted ceilings A longer downrod is sometimes necessary to ensure proper blade clearance Important If using the angle mount check to ensure the ceiling angle is not steeper than 16 Flushmount is not available for this item Closemount is not available for this item Standard Mounting Flushmount Closemount Angle Mounting 3 Ensure the blades T will...

Page 8: ...se direction Detach mounting bracket D from canopy E 5 Attach mounting bracket D to outlet box not included using screws and washers provided with the outlet box CAUTION It is very important to use the proper hardware when installing the mounting bracket D as this will support the fan 6 Discard the orange packing material from the top of the motor assembly H 4 D Standard Mounting Angle Mounting Pa...

Page 9: ...ert the downrod A or a longer downrod not included if required through the canopy E and yoke cover G Feed the wires from the fan through the downrod A 3 Slide the downrod A into the yoke align the holes then re install the downrod pin B and downrod clip C Secure with set screws I and slide the yoke cover G down until it rests on top of the motor assembly H C A I B G Yoke 2 3 A G E Yoke C A B I H 1...

Page 10: ...2 in of insulation from the end of the white wire Twist the stripped ends of each strand of wire within the insulation with pliers not included Repeat the step for the black wire Note If you did not cut back the lead wires in Step 4 Step 5 is not necessary and you may proceed to Step 6 instead 6 Install the ball end of the downrod A into the opening of the mounting bracket D Align a slot in the ba...

Page 11: ...ply wire Connect the Black wire from the fan to the Black supply wire Secure all wiring connections together with wire connectors AA Note The Black wire is hot power for the fan The White wire is common for the fan and light kit The Green wire is the ground wire If household supply wires are different colors than referred to above it is recommended a professional electrician determines the proper ...

Page 12: ...screws J previously removed Step 4 page 8 Tighten all mounting bracket screws J securely 3 Partially insert the blade screws BB along with the blade washers CC through the blade T blade arm S and into the medallion R Tighten each blade screw BB with a Phillips screwdriver not included starting with the one in the middle Repeat this step for the remaining blades T and blade arms S Hardware Used BB ...

Page 13: ... loosened fitter plate screws L Place the light pan M over the three screws and turn the light pan M clockwise Then tighten the three fitter plate screws L Re install the fitter plate screw L that was removed in the previous step and tighten firmly 6 Remove one and loosen the other two light pan screws N from the underside of the light pan M Connect the Single pin connector from the fitter plate K...

Page 14: ... remote from remote pack P and insert the CR2032 batteries Replace the battery cover If battery is installed correctly the LED indicator on the front of the remote transmitter should illuminate when any button is pushed Note If remote doesn t turn on the fan see TROUBLESHOOTING page 17 9 If desired the wall bracket can be installed to the wall using the two mounting screws from the remote pack P S...

Page 15: ...ctive Press Fan On Off to deactivate Light Delay Delays turning off light for one minute which allows safe exit from room Light dims to confirm function is active Press Light Control button to deactivate and turn the light off Security Light Press and hold Security Light button for 3 seconds to activate Lights cycle on for 5 20 minutes and off for 60 minutes simulating occupancy Cycle repeats cont...

Page 16: ...N The fan does not move 1 The power is off or the fuse is blown 2 There is a faulty wire connection 3 The plugs are not connected properly 4 The reverse switch is not completely engaged 1 Turn the power on or check the fuse 2 Turn the power off Loosen the canopy and check all connections 3 Check that the connectors from the light kit fitter and fan are connected properly 4 Push the reverse switch ...

Page 17: ...he yoke until secure The fan operates correctly but the lights are not working 1 The light kit wire plugs are not connected properly 2 There is a faulty wire connection 1 Ensure that the single pin connectors from the light kit are connected properly 2 Turn the power off and check all connections at the ceiling outlet box Remote control does not work 1 Power surge may have cleared memory and remot...

Page 18: ...varying climate conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather conditions Any glass provided with this fan is not covered by the warranty Any replacement of defective parts from the ceiling fan must be reported within the firs...

Page 19: ...D Mounting Bracket 4L000008860 4L000007490 E Canopy 4L000015740 4L000015730 F Canopy Cover 4L000002190 4L000002900 G Yoke Cover 4A000009350 4A000005540 O Light Kit 4L000015750 4L000015750 P Remote Pack 4L000015780 4L000015780 Q Glass Bowl 4L167560001 4L167560001 R Medallion x6 4L074500002 4L074500001 S Blade Arm x6 4L074470002 4L074470001 T Blade x6 4L086230002 4L086230001 HW Hardware Kit 4L000015...