background image

5

SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install the 

product.
• 

Before you begin installing the fan, disconnect the power by removing fuses or turning off the circuit 

breakers.

•  Make sure all electrical connections comply with local codes, ordinances, the National Electrical 

Code and ANSI/NFPA 70-199. Hire a qualified electrician or consult a do-it-yourself wiring 

handbook if you are unfamiliar with installing electrical wiring.

•  Make sure the installation site you choose allows a minimum clearance of 7 ft. from the blades to 

the floor and at least 30 in. from the end of the blades to any obstruction.

•  The net weight of this fan is:  15.7 lbs.

 

DANGER:

 When using an existing outlet box, make sure the outlet box is securely attached to 

the building structure and can support the full weight of the fan. Failure to do this can result in serious 

injury or death. The stability of the outlet box is essential in minimizing wobble and noise in the fan 

after installation is complete.

 

WARNING:

 To avoid personal injury, the use of gloves may be necessary while handling fan 

parts with sharp edges.

 

WARNING:

 Using a full-range dimmer switch to control fan speed will cause a loud humming 

noise from the fan. To reduce the risk of fire or electric shock, do NOT use a full-range dimmer switch 

to control the fan speed.

 WARNING: 

To reduce the risk of fire, electric shock or personal injury, mount the fan to an 

outlet box marked “ACCEPTABLE FOR FAN SUPPORT” and use the mounting screws provided with 

the outlet box. Most outlet boxes commonly used for the support of lighting fixtures are not acceptable 

for fan support and may need to be replaced. Consult a qualified electrician if in doubt. Secure the 

outlet box directly to the building structure. The outlet box and its support must be able to support the 

moving weight of the fan (at least 35 lbs.). Do NOT use a plastic outlet box.

 WARNING: 

To reduce the risk of fire, electrical shock or personal injury, wire connectors 

provided with this fan are designed to accept only one 12-gauge house wire and two lead wires from 

the fan. If your house wire is larger than 12-gauge or there is more than one house wire to connect to 

the two fan lead wires, consult an electrician for the proper size wire connectors to use.

 WARNING: 

To reduce the risk of fire or electric shock, do not use the fan with any solid-state 

speed-control device or control the fan speed with a full-range dimmer switch.

 WARNING: 

To reduce the risk of fire, electric shock or personal injury, do not bend the blade 

arms when installing them, balancing the blades or cleaning the fan. Do not insert objects between 

the rotating fan blades.

 WARNING: 

To reduce the risk of personal injury, use only parts provided with this fan. The use 

of parts OTHER than those provided with this fan will void the warranty.

Summary of Contents for 41169

Page 1: ... Purchase Date _________________________ ITEM 1607162 43105016 0888516 43105022 BELLEISLE BAY CEILING FAN MODEL 41169 41172 Français p 23 RR20002 Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 8 p m EST Monday Sunday ...

Page 2: ...aration 6 Initial Installation 7 Standard or Angle Mounting Instructions 9 Closemount Instructions 12 Secondary Hanging System 13 Wiring 14 Final Installation 15 Operating Instructions 18 Care and Maintenance 19 Troubleshooting 19 Limited Lifetime Warranty 21 Replacement Parts List 22 ...

Page 3: ... Canopy E 1 G Motor Assembly 1 H Fitter Plate preassembled to the Motor Assembly G 1 I Light Kit 1 J Yoke Cover 1 K Blade 3 L Bulb 2 M Glass Bowl 1 N Remote Pack 1 O Phillips Head Closemount Screw preassembled to the Motor Assembly G 3 P Mounting Bracket Screw preassembled to the Mounting Bracket D 4 Q Set Screw preassembled to the Motor Assembly G 2 R Fitter Plate Screw preassembled to the Fitter...

Page 4: ...RE CONTENTS Wire Connector Qty 6 1 extra Blade Screw Qty 9 1 extra Blade Washer Qty 9 1 extra Secondary Support Screw Qty 1 Support Washer Qty 1 Secondary Spring Washer Qty 1 shown actual size AA BB CC JJ KK MM ...

Page 5: ... dimmer switch to control the fan speed WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an outlet box marked ACCEPTABLE FOR FAN SUPPORT and use the mounting screws provided with the outlet box Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in...

Page 6: ...ing two conditions 1 This device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device if applicable PREPARATION Before beginning the assembly of this product ensure that all parts are present Compare all parts with the package contents list and hardware contents list If any part is missing or damaged do no...

Page 7: ...ting is best suited for angled or vaulted ceilings A longer downrod is sometimes necessary to ensure proper blade clearance Important If using the angle mount check to ensure the ceiling angle is not steeper than 10 Flushmount installation is not available for this item Closemount installation is more suitable for ceilings lower than 8 ft high 3 Ensure the blades K will be at least 30 in from any ...

Page 8: ...nopy E Set aside for later use Detach mounting bracket D from canopy E 5 Attach mounting bracket D to outlet box not included using screws and washers provided with the outlet box CAUTION It is very important to use the proper hardware when installing the mounting bracket D as this will support the fan 5 4 E D P D D Standard or Closemount Mounting Angled Mounting ...

Page 9: ... a longer downrod if required through the canopy E and yoke cover J Feed the wires and braided cable from the fan through the downrod A 3 Slide the downrod A into the yoke of the motor assembly G align the holes then re install the downrod pin B and downrod clip C Secure with set screws Q and slide the yoke cover J down until it rests on top of the motor assembly G C A B Q G A J C A J Q B G E 2 3 ...

Page 10: ...trip 1 2 in of insulation from the end of the white wire Twist the stripped ends of each strand of wire within the insulation with pliers not included Repeat the step for black and blue wires Note If you did not cut back the lead wires in Step 4 Step 5 is not necessary and you may proceed to Step 6 instead 6 Install the ball end of the downrod A into the opening of the mounting bracket D Align the...

Page 11: ...TANDARD OR ANGLE MOUNTING INSTRUCTIONS 7 Insert the receiver from remote pack N into the mounting bracket D with the flat side facing the ceiling Proceed to Secondary Hanging System on page 13 D 7 Receiver ...

Page 12: ...ews O from the top of the motor assembly G Align the canopy E with the holes in the top of the motor assembly G then re install the Phillips head closemount screws O to secure the canopy E to the top of the motor assembly G 3 Raise the fan and place the canopy E on the hook on the mounting bracket D Then place the receiver from remote pack N inside the mounting bracket D with flat side facing the ...

Page 13: ...dary support screw JJ Note The ceiling support brace may not be accessible from below If not it must be accessed from above Important The braided cable must make a complete circle around the support brace to secure the fan Hardware Used JJ Secondary Support Screw x 1 Support Washer x 1 Secondary Spring Washer x 1 3 Tighten the secondary support screw JJ securing the braided cable Hardware Used JJ ...

Page 14: ... from the receiver from remote pack N to the Black fan wire Connect the Red wire with red label from the receiver from remote pack N to the Black hot power supply wire Connect the White wire with red label from the receiver from remote pack N to the White neutral supply wire Connect the White wire with white label from the receiver from remote pack N to the White fan wire Important The Blue fan wi...

Page 15: ...keyholes of the canopy E onto the mounting bracket screws P and rotate the canopy E clockwise 2 Secure the canopy E with the mounting bracket screws P previously removed Step 4 page 8 Tighten all mounting bracket screws P securely 1 2 E P P D E Note Closemount installation will not use the downrod A yoke cover J or canopy cover F ...

Page 16: ... to the fitter plate H and loosen the other two but do not remove Connect the single pin connector from the fitter plate H to the single pin connector from the light kit I blue to blue and white to white Align the slotted holes in the light kit I with the loosened screws in the fitter plate H Turn light kit I clockwise and replace the previously removed fitter plate screw R Tighten all screws 5 In...

Page 17: ...ction until it is secure 7 If desired the clip in remote pack N can be installed to a wall using the provided clip screws The remote from remote pack N can hang from the clip for easy access 8 Turn on the circuit breakers and the wall switch to the fan supply lead lines Assembly is complete M I 7 6 Clip Clip Screw Remote 8 ...

Page 18: ... off Press and hold this button to dim or brighten the lights if applicable 3 The reverse switch is located on the top of the motor assembly G Using a ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort 3a In warmer weather push the reverse switch to the left to display a Sun icon which will ...

Page 19: ...RRECTIVE ACTION The fan does not move 1 The power is off or the fuse is blown 2 There is a faulty wire connection 3 The plugs are not connected properly 4 The reverse switch is not completely engaged 1 Turn the power on or check the fuse 2 Turn the power off Loosen the canopy and check all connections 3 Check that the connectors from the light kit fitter and fan are connected properly 4 Push the r...

Page 20: ...o the yoke until secure The fan operates correctly but the lights are not working 1 The bulbs are not installed correctly 2 The light kit wire plugs are not connected properly 3 There is a faulty wire connection 1 Re install the bulb s 2 Ensure that the male and female plugs in the light kit fitter are connected properly 3 Turn the power off and check all connections at the ceiling outlet box Remo...

Page 21: ... varying climate conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather conditions Any glass provided with this fan is not covered by the warranty Any replacement of defective parts from the ceiling fan must be reported within the fir...

Page 22: ... Downrod 4L000010220 4L000010240 D Mounting Bracket 4L000006280 4L000004480 E Canopy 4L000004350 4L000004470 F Canopy Cover 4L000002900 4L000004500 I Light Kit 4L000012710 4L000012720 J Yoke Cover 4L000002870 4L000006000 K Blade x5 4L000002880 4L000002880 M Glass Bowl 4L163970002 4L163970002 N Remote Pack 4L000011920 4L000011920 HW Hardware Kit 4L000012730 4L000012740 9099 PB 021720 A D E F J I N ...