Installation Instructions:

LUNOS e

2

 and e

2

 short with 

5/UNI-FR No.:40269 Controller

CONTENTS

Questions? Email: [email protected] |  Call: 800-995-6329

1

About this manual, Safety instructions
Technical Specifications
Dimensional Diagrams
Installation Position
Operating Conditions 
Shipping Units
Assembly: Assembly pipe and outside grid
Assembly: Electric installation and electric connection
Assembly: Heat recovery unit and indoor blind
Operation
Controller Dial Settings / Flow Rate Selection 
Filter Indicator Reset + Summer Vent Mode Operation

1
1
2
2
2
3
3 - 4
4 - 5
6
6
7
7

ABOUT THIS MANUAL

Read this manual carefully and completely before assembly. Comply with the general safety instructions 
symbols with information in the text.

Hand out this manual to the user (tenant, proprietors, property management, etc.) after completing 
assembly.

Symbols in this manual

 

  This symbol is a danger warning in connection with risk of injury or product malfunction

 

This symbol is a danger warning in connection with risk of injury from electricity

Safety instructions 

Beware! Any assembly work to the ventilation device may only be carried out after disconnecting all 

phases of supply currents! The ventilation device is fitted with protective insulation according to Protection Class 
II, the protection connection is superfluous!

 

 Attention! The electric connection may only be authorized by qualified electricians according to the local 

building codes.

 

 Attention! This device may not be operated (including filter replacements/cleaning) by children and persons 

who are not able to operate the device safely due to their abilities, or Lack of knowledge.

Device voltage:  12 VDC SELV
Type of protection: IP 22
Volume flow: 10;15;20 CFM or 
(9CFM-15m3/h;18CFM-30m3/h,22CFM-38m3/h)
Measuring sound pressure level: 16,5 dB; 19,5 dB
Sound level difference: 42 dB
UL: fans are certified to the UL 507-2010: Electric 
Fans 9th Edition

TECHNICAL SPECIFICATIONS

DISPOSAL

Dispose of the packaging correctly 
sorted. If you want to dispose of the 
device, abide by the current rules and 
regulations. The applicable municipal 
office will provide information.

Summary of Contents for e2

Page 1: ...ol is a danger warning in connection with risk of injury from electricity Safety instructions Beware Any assembly work to the ventilation device may only be carried out after disconnecting all phases...

Page 2: ...volume is equal to the total exhausted volume If a pair of fans in this balanced push pull operation is installed in two different rooms of a dwelling a sufficiently dimensioned interconnection under...

Page 3: ...llation pipe exterior white grill heat exchanger unit indoor cover optional condensate ring and installation instructions are supplied as a complete set Indoor Cover Heat Exchange Unit Outside Grill I...

Page 4: ...terior grill finishes are also available in stainless steel grey burgundy and white Safety Instructions Beware Any assembly work to the ventilation device may only be carried out when all of the suppl...

Page 5: ...or the supply voltage to the transformer power supply unit 14 gauge Double Rocker Switch Connection W1 W2 grey red black Rocker switch front view Rotary Switch Connection grey red black Device connect...

Page 6: ...lter casing snap the interior blind into place in open position off wall If cover completed covered lift cover and rotate 180 Installation is now complete When operating the Lunos e2 using a double ro...

Page 7: ...5 supply Call 800 995 6329 Exhaust air without heat recovery Unpaired operation with 1 unit connected to S1 and two units connected to S2 7 The LED will permanently light in red when the lter is due t...

Reviews: