WARNING:
To reduce the risk of fire, electrical
shock or personal injury, wire connectors provided
with this fan are designed to accept only one
12-gauge house wire and two lead wires from the fan.
If your house wire is larger than 12-gauge or there is
more than one house wire to connect to the
corresponding fan lead wires, consult an electrician
for the proper size wire connectors to use.
CAUTION:
Be sure outlet box is properly
grounded and that a ground (GREEN or BARE) wire
is present.
WARNING:
If house wires are different colors
than referred to in the following steps, stop
immediately. A professional electrician is
recommended to determine wiring.
WARNING:
Using a full range dimmer switch
(not included) to control fan speed will cause a loud
humming noise from fan. To reduce the risk of fire or
electrical shock, do NOT use a full range dimmer
switch to control fan speed.
WIRING
NOTE:
This fan is remote control adaptable (remote
control not included). Please refer to instructions
provided with the remote control before proceeding
with these wiring instructions.
12
Choose wiring diagram (Fig. 1a, Fig. 1b or Fig. 1c)
that fits your situation and make appropriate wiring
connections as follows: [
IMPORTANT:
Use one of
the wire connectors (CC) provided to make each wire
connection, making sure to screw wire connector
(CC) on in a clockwise direction.]
1a.
FAN AND LIGHT CONTROLLED BY PULL
CHAINS:
Connect BLACK and BLUE wire from fan
to BLACK wire from ceiling. Connect WHITE wire
from fan to WHITE wire from ceiling. Connect
GROUND (GREEN) wires from downrod (A) and
mounting bracket (C) to BARE/GREEN wire from
ceiling.
1.
FAN AND LIGHT CONTROLLED BY TWO WALL SWITCHES
1a
FAN AND LIGHT CONTROLLED BY PULL CHAINS
120V POWER
FROM CEILING
GREEN
WHITE
BLACK
BLUE
BLACK (POWER)
WHITE (NEUTRAL)
GROUND/GREEN (BARE)