Programmable Temperature & Humidity Controller
46
5. Time signal setting
Up to 20 time signals can be set.
① Set OFF time. Time signal is on after waiting for defined time from the start point of segment.
② Set ON time. Time signal is on during defined time from the ON point of segment.
[Time signal parameter]
Parameter
Setting range
Default
OFF Time
0~9999 [M]
0
ON Time
0~9999 [M]
0
●
Time signal operation
Fig. 55) Time signal
Fig. 56) Time signal operation
ON
TS1
SEGMENT
OFF
(N-1) SEG TIME
(N+1) SEG TIME
N SEG TIME
ON Time
ON
TS2
SEGMENT
OFF
(N-1) SEG TIME
(N+1) SEG TIME
N SEG TIME
ON
Time
OFF Time
ON
TS3
SEGMENT
OFF
(N-1) SEG TIME
(N+1) SEG TIME
N SEG TIME
ON Time
ON
TS4
SEGMENT
OFF
(N-1) SEG TIME
(N+1) SEG TIME
N SEG TIME
ON
Time
OFF
Time
1. TS1
1) seg tIMe ≥ off tIMe + on tIMe
2) off tIMe = 0
2. TS2
1) seg tIMe ≥ off tIMe + on tIMe
2) off tIMe
≠
0
3. TS3
1) seg tIMe
<
off tIMe + on tIMe
2) off tIMe = 0
4. TS4
1) seg tIMe
<
off tIMe + on tIMe
2) off tIMe
≠
0