HANYOUNG NUX TH510 Series Operation Manual Download Page 1

هﺮﮐ

 

ﮓﻧﺎﯿﻧﺎﻫ

 

تﻻﻮﺼﺤﻣ

 

یرﺎﺼﺤﻧا

 

هﺪﻨﯾﺎﻧﻤ

 

ناﻮﯿﺳ

 

ﺖﮐﴍ

021-33989001

www.sivancarno.com

021-33989002

Summary of Contents for TH510 Series

Page 1: ...021 33989001 www sivancarno com 021 33989002...

Page 2: ...t prior notice Hanyoung Nux Co Ltd shall not be responsible for anything not specified in this user manual including but not limited to implicit warranty of properness of a certain purpose The accompa...

Page 3: ...ng 28 3 PV graph view 33 4 Time schedule setting 35 5 Event 36 1 Pattern setting 39 2 Pattern management 42 3 Pattern name setting 44 4 Pattern alarm setting 45 5 Time signal setting 46 6 Pattern grap...

Page 4: ...tion manual describes product functions how to install cautions and how to use Read and understand this document before starting the product Make sure that this operation manual will be delivered to a...

Page 5: ...r module Control module N No input output Language S Korean English and Chinese Simplified T Korean English and Chinese Traditional This product consists of the display and control power control input...

Page 6: ...e Failure attributable to unstable power supply If you require A S contact your dealer or Hanyoung Nux Co Ltd 2 Safety cautions The operation manual may be subject to changes for improvement without p...

Page 7: ...g Please make sure that the power is within the rating to avoid any product damage leading to fire or electric shock Do not touch it with wet hand You may be electrically shocked Follow conventional c...

Page 8: ...stall the panel 2 How to install VESA mount 1 2 3 4 5 DC 5V 6 7 8 COM1 COM2 75 0 75 0 4 M4 Connect an M4 X 7L bolt into a VESA hole The tightening torque must be 0 5 N m or less for clamping Forcible...

Page 9: ...RY5 RY3 RY7 RY4 RY8 TM DO ADR PWR RY2 RY6 RY1 RY5 RY3 RY7 RY4 RY8 PWR RY2 RY6 RY1 RY5 RY3 RY7 TM DO ADR PWR RY2 RY6 RY1 RY5 RY3 RY7 RY4 RY8 TM DO ADR PWR RY2 RY6 RY1 RY5 RY3 RY7 RY4 RY8 TM DO ADR PWR...

Page 10: ...75 0 75 0 24 7 35 5 4 M4 Display Unit 2 How to attach panel Referring to the hole dimensions on the left find where to install it Push outside the top and bottom hooks for fixing screws at the bottom...

Page 11: ...5 0 8 8 42 3 1 2 3 4 5 DC 5V 6 7 8 COM1 COM2 75 0 75 0 24 7 35 5 4 M4 Panel dimensions Unit Power module Unit 13 8 73 2 8 0 17 0 112 0 95 0 36 3 35 50 0 13 0 67 0 10 0 88 0 107 0 95 0 4 2 4 2 Control...

Page 12: ...ter for AC circuit and the diodes for DC circuit should be connected in parallel with the inductive load Caution Input wire must use shielded cable and be wired with certain distance from the power an...

Page 13: ...ess terminal Power Input Output M3 screw Temperature Humidity control output SSR or SCR Recording and indicating instrument etc Temperature Humidity transmission output Temperature Humidity control an...

Page 14: ...RY4 RY8 COM1 RUN COM2 TM DIO ADR PWR RY2 RY6 RY1 RY5 RY3 RY4 TH510 MAIN ADR TM DI ADR PWR Terminal No Output 1 4 Terminal No Output 5 8 1 10 2 11 3 12 4 13 5 14 6 15 7 16 8 17 9 18 RY1 RY2 RY3 RY4 RY5...

Page 15: ...m System setting Specifications 1 Name of section Display Front LED Power switch SD card slot Back light OFF STOP Red lamp ON RUN Red lamp flashing Back light ON STOP Green lamp ON RUN Green lamp flas...

Page 16: ...sets numbers and characters Press it to display the numeric or character input panel Displays parameter names and setting ranges Displays setting values Registers setting values Remove the last digit...

Page 17: ...4 How to control character input panel Displays parameter names Displays setting characters Registers setting characters Remove the last digit of setting characters Remove the entire setting value Can...

Page 18: ...connected COM1 Displays communication state of the display and control OFF when OK COM2 Displays communication state of the control and I O OFF when OK LED specifications Input output module PWR Lamp...

Page 19: ...failure operation screen and switch time settings Save setting Save interval media and parameter upload download settings Graph Background color and file save name System menu Program Pattern setting...

Page 20: ...view Go to saved PV graph screen 4 Program Go to program setting pattern setting graph etc screen 5 Date Time Go to current time and schedule setting screen 6 Event Go to event and error history scree...

Page 21: ...the temperature Target Set Value TSG 9 Show the temperature present set value NSV Show only during operation 10 Show the temperature increase decrease maintenance status 11 Show the humidity Present...

Page 22: ...during operation 10 Show the temperature increase decrease maintenance status 11 Show the humidity Present value PV 12 Show the humidity unit 13 Show the humidity control output MV 14 Input the humid...

Page 23: ...uning is in execution it runs with current setting values 2 Press User defined button to run assigned relay in Main menu System menu DO configuration 3 Go to DI state check screen Fig 13 Fixed control...

Page 24: ...setting values and calculates PID integer by measuring hunting cycle and amplitude Enter setting values SV in the constant value control mode run press button window and press temperature or humidity...

Page 25: ...progression during the operation 9 Show the temperature present set value NSV Show only during operation 10 Show the temperature increase decrease maintenance status 11 Show the humidity Present valu...

Page 26: ...15 Show the humidity present set value NSV Show only during operation 16 Show the humidity increase decrease maintenance status 17 Show the temperature humidity PID number in application 18 Show the p...

Page 27: ...progress now and force to move to the next segment 3 During the auto tuning execution proceed the auto tuning with the present set value 4 By pressing the user key Main Menu System Menu DO configurat...

Page 28: ...cture 23 1 DI status screen2 Step Hold This function is enabled only during program operation Enter a key or set Hold Step in System menu DI configuration Configuration type and then set external cont...

Page 29: ...munication error The module and communication in the input output address 1 do not work IO 2 Module communication error The module and communication in the input output address 2 do not work IO 3 Modu...

Page 30: ...ion the temperature rising time may be delayed according to the load and the present value may not reach the set value undershoot Parameter Description Fixed To control temperature with certain settin...

Page 31: ...tions Use to limit the touch panel input Only operation screen and move buttons enabled If password set in System setting System enter the password to change it Use to limit entering to main menu When...

Page 32: ...BEEP sound Cancel Set Set Touch input lock Cancel Set Cancel Main menu password enter 0 9999 0 User button name Up to 14 characters User button Function setting parameter Password input screen Set dat...

Page 33: ...creen 3 and PV graph view screen 2 Select the thickness of line of graph shown in Operation screen 3 and PV graph view screen 3 Select background colors for the operation screen 3 PV graph view and pa...

Page 34: ...on Fig 33 Line thickness 2 pixels Fig 35 Background color Black Fig 34 Line thickness 1 pixel Ambient Set the ambient operation time Parameter Setting range Default ambient operation time 0 9999 min 0...

Page 35: ...ze scales 6 Displays or hides graph of selected value 7 Displays time unit by gradation 8 Displays position of data specified by the base line 9 Base line to display values 10 Go to beginning of data...

Page 36: ...p size scale Scale factors are x1 x2 x4 and x8 6 Scale down size scale The smallest scale factor is x1 No Description 1 Select a file 2 This is the name of saved file The name can be changed in Graph...

Page 37: ...Min 0 60 Parameter Setting Default Operation day Monday Tuesday Wednesday Thursday Friday Saturday Sunday AM PM AM PM AM Hour 1 12 12 Minutes 0 60 0 Reservation confirm cancel set cancel Present time...

Page 38: ...to error Fix operation normal end Fix operation ended normally Program operation start manual Program operation started by RUN button Program operation start communication Program operation started by...

Page 39: ...aving in SD card started SD card save stop Saving in SD card stopped SD card save stop no memory Saving in SD card stopped because of SD card removal SD card save stop over capacity Saving in SD card...

Page 40: ...r Error in humidity calibration Humidity input connection error Error in humidity input connection I O nn connection error No connection in I O nn D I nn occur contact input D I nn occurred D I nn can...

Page 41: ...humidity chamber electric furnace etc On this screen you can set the parameters related to program controls 1 Pattern setting PROGRAM No Description 1 Change the pattern No Pattern 1 100 2 Move by 5...

Page 42: ...9999 H 0 0 59 M 0 Waiting Release Cancel set 0 Segment parameters No Description 1 Set the temperature settings value of the segment 2 Set the humidity settings value of the segment 3 Set the operati...

Page 43: ...ttern alarms up to 4 of them can be selected for a segment n 1 4 Parameter Setting Default P AL n 0 8 0 Alarm parameter T S Among 20 time signals up to 4 of them can be selected for a segment n 1 4 Pa...

Page 44: ...ration Set Start mode If SSV is set to Start mode start SV can be set by channel Parameter Description Stop operation Stop operation when current pattern is finished Holding seg Continue operation wit...

Page 45: ...V is out of defined wait range Wait operation is cancelled because PV is within defined wait range If measurement PV is out of wait range it waits until the measurement PV enters the wait range for de...

Page 46: ...d pattern No 1 100 1 3 Pattern name setting Go to other page Up to 8 pattern names can be set per page Change a pattern name If the language is Korean use Caps to enter Korea English upper case Englis...

Page 47: ...te upper limit Absolute lower limit Upper limit of offset Lower limit of offset Out of range Within range ON OFF HYS A POINT ON OFF HYS A POINT ON SV OFF HYS A POINT ON SV OFF HYS A POINT ON ON SV OFF...

Page 48: ...signal operation Fig 55 Time signal Fig 56 Time signal operation ON TS1 SEGMENT OFF N 1 SEG TIME N 1 SEG TIME N SEG TIME ON Time ON TS2 SEGMENT OFF N 1 SEG TIME N 1 SEG TIME N SEG TIME ON Time OFF Ti...

Page 49: ...o program menu screen 2 Change patter No No 1 100 3 Blue background color is the progress of operation 4 Displays time by gradation 5 Go to beginning of pattern graph 6 Go to previous screen 7 Go to n...

Page 50: ...een and change user password For more details refer to page 74 Caution System setting is a pre installed basic setting condition so you need special attention when you change them There is no need for...

Page 51: ...put filter Enter a digital filter value of input 4 Burn out range setting Operators can set burn out range For example if operator set 10 with the temperature range 100 200 the equipment stops when th...

Page 52: ...ting DCV sensor range DCV high setting limitation RTD low setting limitation DCV input low setting limitation RTD only available with the default setting DCV sensor range DCV low setting limitation Te...

Page 53: ...ity is figured out by the difference between Dry and Wet bulb temperatures it is very important to adjust each temperature Adjustment after when both temperature values are stable is recommended ADJUS...

Page 54: ...anual When the mode is MANUAL operator can set the ARW zone manually Temperature Humidity Control output 2 Control transmission output setting Parameter Setting Range Default Output mode SSR SCR SSR S...

Page 55: ...he output is 20 100 According to the voltage pulse output cycle control output is ON for certain time OFF for the rest If current output is selected it shows relation between control output MV and out...

Page 56: ...upper lower limit value 3 Sensor Burnt out Select between 0mA and 4mA Temperature Humidity Retransmission Output Parameter Setting Range Default Output Type PV MV SV PV Output Upper Limitation Value...

Page 57: ...to copy all PID values of it to a target channel 4 A T GAIN Used to manually and finely optimize PID numerical values automatically calculated with constant values applied to individual PID items for...

Page 58: ...ility Auto tuning gain A T gain 1 Temperature range value The range is decided automatically by user s temperature setting range 2 Humidity range value The range is decided automatically by user s hum...

Page 59: ...sed to reduce the offset If the integral time is too long it is changed too late but if it is too short there might be frequent hunting 3 Derivative D time Set derivative time To compensate for sharp...

Page 60: ...nner signal 1 Target setting Set a target of inner signal 2 Range direction Set the operation range of temperature to use inner signal 3 Type Set a target of inner signal to apply T S V Based on targe...

Page 61: ...limits of operation range for target 5 Operation delay Set operation delay for target 6 Operat ion Mode Always always execute the inner signal Running execute the inner signal during operation only 1...

Page 62: ...1 is an example of setting inner signal I S NSV Inner signal No 1 3 and 8 are set with temperature NSV and Within range so that the inner signal is turn on or off according to change of current settin...

Page 63: ...peration 4 LU Set lower limit offset of ON OFF signal operation 5 HD Set upper limit offset of ON OFF signal operation Temperature Humidity setting 5 ON OFF signal Parameter Setting range Default L SV...

Page 64: ...ffset Zone B M SV PV H SV 1 Hd 0 Always OFF regardless of offset 2 Hd 0 Refer to Fig 91 OFF PV SV Hd ON PV SV Hd Zone C L SV PV M SV 1 Lu 0 Always ON regardless of offset 2 Lu 0 Refer to Fig 92 OFF PV...

Page 65: ...0 100 0 0 0 0 Hysterisys EUS 0 100 0 0 Delay Min 0 9999 0 Alarm direction Direct Reverse Direct Hold On Off Off Fig 93 System alarm Temperature Fig 94 System alarm Humidity Absolute upper limitation...

Page 66: ...are set to Run Stop Hold and Step 3 Detection delay Enter delay time after DI is detected Common 7 DI configuration 1 Enter a system alarm name using Korean English numeric and symbol characters 2 A...

Page 67: ...f it cancels hold For program operation 3 DI 3 operation type Set function for DI 3 operation Error DI 3 operation is used as an error Step DI 3 error forces transition from current segment to next on...

Page 68: ...ter DI occurrence may be set by DI 1 Enter a DI error name using Korean English numeric and symbol characters 2 Entered DI error name is shown on DI error screen for the error 3 A DI error name may in...

Page 69: ...ser defined image in the internal memory basic image is shown 1 State display Upload progress is shown 2 Upload Upload selected image files of SD card to the internal memory It can t operate when it i...

Page 70: ...efined image in the internal memory 1 State display Image deletion progress is shown 2 Delete Delete a selected image files in the internal memory 3 There is no user defined image in the internal memo...

Page 71: ...ble relay numbers are limited by the option so make sure to check the IO specifications Screen to set relays for inner signals If an inner signal is transmitted defined relay is ON Screen to set relay...

Page 72: ...e setting time it turns ON it operates just during the first ON ON OFF signal Parameter Setting range Default Temperature ON OFF signal Up to 0 32 0 Humidity ON OFF signal Up to 0 32 0 Screen to set r...

Page 73: ...tion Set Temperature and Humidity sensor disconnection signal relays and ON time 3 Ascending section Set ascending signal relay and offset Offset Target setting value Temperature or Humidity value 4 H...

Page 74: ...y Max 0 32 0 Temperature holding range deviation 0 9999 0 min Humidity holding range relay Max 0 32 0 Humidity holding range deviation 0 9999 0 min Temperature descending range relay Max 0 32 0 Temper...

Page 75: ...activates upon the equipment running relay 6 User Key Setting relay and delay time of user button If you activate the button window in the operation screen it is possible to operate the user button a...

Page 76: ...ferent relay 8 is ON 5 When 25 seconds elapsed after relay 8 is ON relay 9 is ON 2 Operator Operation signal AND Output relay is ON if both operation value 1 and 2 are ON OR Output relay is ON if eith...

Page 77: ...ish Chinese Select a splash If a user password is set it needs to be entered to enter system setting screen If the user password is 0 it is disabled Upload a splash using a SD card disabled when it is...

Page 78: ...length 7 8 8 Parity bit NONE EVEN ODD NONE Unit No 1 99 Up 32 units can be connected including master 1 Response time 0 100 0 Screen to set hardware state of control module Normal operation is enabled...

Page 79: ...before Caution Indicator Screen to set indicators on constant value and program operation screens Up to 32 indicators can be selected Up to 16 of them can be displayed in 1 screen and tap them to swi...

Page 80: ...must reboot the display and control module User attention is required for upgrading firmware so make sure to set the password Default password is 0 Upgrade files can be downloaded from Hanyoung Nux we...

Page 81: ...ion 30 V A max Max rating of internal fuse 250 V AC Dielectric strength Between 1st and 2nd terminals Min 1500 V AC for 1 min Between 1st and FG terminals Min 1500 V AC for 1 min Between 2nd and FG te...

Page 82: ...andom Refresh interval 250 ms Max number of input 32 Contacts Input type No voltage contact input ON OFF sensing resistor Minimum 1 and less On maximum 10 and more Off recognition Min sensing time 0 2...

Page 83: ...ional band 0 00 100 00 For 0 00 ON OFF control Integral time 0 0 3 000 sec OFF when 0 sec Derivative time ON OFF control Set 0 0 to proportional band PB Normal Open Normal Close According to selection...

Page 84: ...erature 20 70 Temperature fluctuation 20 h or less Ambient humidity 5 95 RH Without condensation Influence of ambient temperature DC voltage 0 003 of F S Thermoresistor sensor 0 03 6 Engineering Units...

Page 85: ...MA0803E170217 Hanyoung Nux Co Ltd 28 Gilparo 71 beongil Namgu Incheon Korea TEL 82 32 876 4697 FAX 82 32 876 4696 www hynux com 021 33989001 www sivancarno com 021 33989002...

Reviews: