background image

1

2

 

STAR-DELTA Timer

 

MA4SD

      

 

        

 

Thank you for purchasing HANYOUNG product.

        Please check whether the product is the exactly same as you ordered. 
        Before using the product, please read this instruction manual carefully.
        Please keep this manual where you can view at any time

 

28, Gilpa-ro 71beon-gil, Nam-gu, Incheon, Korea

TEL:(82-32)876-4697 FAX:(82-32)876-4696 
http://www.hynux.net

HANYOUNGNUX CO.,LTD

HEAD OFFICE

JL.CEMPAKA BLOK F 16 NO.02 DELTA SILICON II INDUSTRIAL PARK
LIPPO CIKARANG CICAU, CIKARANG PUSAT BEKASI 17550 INDONESIA
TEL : 62-21-8911-8120~4  FAX : 62-21-8911-8126 

PT. HANYOUNG ELECTRONIC INDONESIA

INDONESIA

FACTORY

 INSTRUCTION MANUAL

 MD0801KE130226

Safety information

Before using the product, please read the safety information thoroughly and use it properly.Alerts declared in the manual 
are classified to Danger, Warning and Caution by their criticality

DANGER

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury

WARNING

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury

CAUTION

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury

Danger

Warning

Caution

• The contents of this manual may be changed without prior notification.

• Before using the product you purchased, make sure that it is exactly what you ordered.
• Make sure that there is no damage or abnormality of the product during delivery.
• Do not use this product at any place with corrosive (especially noxious gas or ammonia) or flammable gas.
• Do not use this product at any place with direct vibration or impact.
• Do not use this product at any place with liquid, oil, medical substances, dust, salt or iron contents.
•Do not polish this product with substances such as alcohol or benzene.
• Do not use this product at any place with a large inductive difficulty or occurring static electricity or magnetic noise.
• Do not use this product at any place with possible thermal accumulation due to direct sunlight or heat radiation.
•Install this product at place under 2,000 m in altitude.
• When the product gets wet, the inspection is essential because there is a danger of electric leakage or fire.
• If there is excessive noise from the power supply, using insulating transformer or noise filter is 

recommended. The noise filter must be attached to a panel which is already connected to a ground and 
the wire between the filter output and power supply terminal must be as short as possible.

•If puttig power cables closely together then It is effective against noise.
•Do not connect anything to the unused terminals.
•After checking the polarity of terminal, connect wires at the correct position.
• When this product is connected to a panel, use a circuit breaker or switch  approved with IEC60947-1 or IEC60947-3.
•Install the circuit breaker or switch at near place for convenient use.
• Write down on a label that if the circuit breaker or switch is operating then the power will be 

disconnected since the circuit breaker or switch is installed.

• For the continuous and safe use of this product, the periodical maintenance is recommended.
• Some parts of this product have limited life span, and others are changed by their 
• The warranty period for this product including parts is one year if this product is properly used

• If there is a possibility of an accident caused by errors or malfunctions of this product, install external 

protection circuit to prevent the accident.

• This product does not contain an electric switch or fuse, so the user needs to install a separate electric 

switch or fuse externally. (Fuse rating : 250 V 0.5 A)

• To prevent defection or malfunction of this product, supply proper power voltage in accordance with the rating.
• To prevent electric shock or malfunction of product, do not supply the power until the wiring is completed.
• Since this product is not designed with explosion-protective structure, do not use it any place with 

flammable or explosive gas.

• Do not decompose, modify, revise or repair this product. This may be a cause of malfunction, electric shock or fire.
• Reassemble this product while the power is OFF. Otherwise, it may be a cause of malfunction or electric shock.
• If you use the product with methods other than specified by the manufacturer, there may be bodily 

injuries or property damages.

•  Due to the danger of electric shock, use this product installed onto a panel while an electric current is applied.

There is a danger of occurring electric shock in the input/output terminals so please never let your body or 
conductive substance is touched.

•Star-delta timer  •8 Pins plug type  •High capacity MOTOR start timer
•Instantaneous contact output, start contact output, DELTA contact output. 
•Various power supply voltage (100 – 240 V a.c 50/60 Hz, 24 – 240 V d.c Dual usage)

Features

Suffix code

Model 

Code

Description

  MA4

Analog multi timer (STAR-DELTA Timer), 48 (W) × 48 (H) ㎜

Control output

SD

   output, △ output

SDI

Instantaneous output,     output, △ output

Υ

Υ

Specification

Model

MA4SD

MA4SDI

Power supply voltage

100 - 240 V a.c 50/60 Hz, 24 – 240 V d.c

Allowable voltage

Power supply voltage ±10 %

Power consumption

Approx. 3.8 VA (100 - 240 V a.c 60 Hz), Approx. 1.9 W (24 – 240 V d.c)

Resetting time

100 ms max

Operating time range

1 ~ 300 sec

Operating time difference

Repeated error : ±0.3 % max, Setting error : ±5 % max, Voltage error : 

±0.5 % max, Temperature tolerance : ±2 % max (Percentage of full scale)

△ Conversion time error

±25 % max

Control 

output

Output mode

Power ON Start

Contact 

composition

     Contact : 1 a, △ Contact : 1 a

   Contact : 1a, △ Contact : 1 a, 

Instantaneous contact : 1 a

Contact capacity

250 V a.c 5 A resistive load

Relay Life span

Mechanical : 5 million times min, Electrical : 100 thousand times min (250 V a.c 5 A resistive load)

Insulation resistance

100 ㏁ min (at 500 V d.c Between current-carrying teminals and exposed noncurrent-carrying metal parts.)

Dielectric strength

2000 V a.c 50/60 Hz 2 minute  

(Between current-carrying terminal and exposed noncurrent-carrying metal parts.)

Noise immunity

±2 kV (Between power terminal, pulse width ±1 ㎲, square wave noise by noise simulator)

Vibration resistance

10 - 55 Hz (For 1 min), Double amplitude 0.75mm, X,Y,Z each direction for 1 hour

Shock resistance

300 ㎨ (30G)  X, Y, Z each direction for 3 times

Ambient temperature

-10 ~ 55 ℃ (icing or dew condensation not allowed)

Storage temperature

-25 ~ 65 ℃ (icing or dew condensation not allowed)

Ambient humidity

35 ~ 85 % R.H.

Weight

Approx. 95g (Including fixing bracket)

Υ

Υ

Υ

Part name and function

MA4SD

×

10 sec

    Operating time range selector
           (Select from 1,2,3,12,30)

 Operation time unit indication 
 (x10 sec fixed)

 Switching time indication 

Operation indication (Red)

Operating time indication

Operation indication (Green)

 Switching time selector 

     △  Switching time

A

50 ms

B

100 ms

C

200 ms

D

300 ms

E

400 ms

F

500 ms

-

Υ

MA4SD

×

10 sec

48.0

48.0

48.0

44.6

77.3

60.0

45.0

45.0

60.0

69.3
46.5

14.8

8.0 8.0

MA4SD

×

10 sec

48.0

48.0

48.0

44.6

77.3

60.0

45.0

45.0

60.0

69.3
46.5

14.8

8.0 8.0

MA4SD

×

10 sec

48.0

48.0

48.0

44.6

77.3

60.0

45.0

45.0

60.0

69.3
46.5

14.8

8.0 8.0

Time

Appearance and panel cutout

[Unit : mm]

▒    Operation time specification

Υ

Operation time range

Operation time 

1.2

1 ~ 12 sec

3

2.5 ~ 30 sec

12

10 ~ 120 sec

30

25 ~ 300 sec

 ※     Select operation time by operation time  
    range selector. 

Υ

Υ

▒    -▵ Switching time specification

Switching time indication letter

Switching time

A

50 ms

B

100 ms

C

200 ms

D

300 ms

E

400 ms

F

500 ms

 ※     -△ Select switching time by switching time  
    selector.

Υ

POWER

(-)

(+)

MA4SDI

MA4SD

POWER

(-)

(+)

POWER

(-)

(+)

MA4SDI

MA4SD

POWER

(-)

(+)

▒ MA4SDI

▒ MA4SD

Connection diagram

Operation specification

 ※  t1 :    Operating time
 ※ t2 :    -△ Conversion time
Caution) MA4SD does not have Instantaneous contact .

Υ 
Υ

Power

Instantaneous

contact 

Contact

 

Y

 Contact

Operation
  indicate

 

Y

▵ 

Operate

    indicate

LED

 

Y

 LED

t1

t1

t2

t2

①-③

②-⑦

⑥-⑧

⑤-⑧

When power is ON,

Instantaneous 

contact and  

contact will be ON.

When reaching to t1 

setting time,  

contact will be OFF. 

And after t2 

switching time, 

 

contact will be ON. 

 contact will be 

ON until Power is 

OFF. 

Y

Y

Reviews: