background image

                                                                                                                                             

Chapter 1    Introduction 

1.1 Introduction 

DDS-3005 USB Arbitrary Waveform Generator has one channel of arbitrary 
waveform output, 8 Bits output, synchronized signal outputs, two channels of 
Counter/Frequency Measurement inputs, 8 Bits input and external trigger input. 
User can edit the waveform arbitrarily by the mouse or choose the regular 
waveforms such as Sine, Square, Tri-angle, Saw-tooth, TTL, White Noise, 
Gauss Noise, Trapezia, Exponent, AM and FM. The parameters, such as 
amplitude, frequency and offset, are also settable. The data format of 
DDS-3005 USB is completely compatible with that of Tektronix; it can directly 
read the waveform data files produced by the Tektronix oscilloscope or 
Tektronix waveform editor software and redisplay the waveform. DDS-3005 
USB adopts the DDS technology so that it has the advantages of high 
frequency accuracy, high waveform resolution, high reliability, and wide 
software support. It can be widely used in the various kinds of electronics labs 
and it offers complete interface for second time development to be jointlessly 
inserted into other auto-measuring systems.   

 

1.2 Working Principle 

The PC transfer the waveform data to the memorizer of the signal generator 
via the USB bus, the ID counter cycles and send the period waveform data to 
the DAC circuits, the DDS (Direct Digital Synthesized) circuit produces the 
corresponding DAC refreshing clock. The waveform of    DAC is outputted 
through the Cache magnifier, Low Pass Filter, and the Magnifier. The 
frequency counter can test the external frequency.   

1.3 Hardware Specification 

Waveform Output Channel 
Frequency Range 

0.1Hz(DC)~5MHz 

Resolution 

0.01Hz 

DAC Clock 

0~50MHz Continuously adjustable, in 
step of 0.2Hz 

Channels 

1CH waveform output 

Memory Depth 

256KSa 

Vertical Resolution 

14 Bits 

Stability 

<30ppm 

Amplitude 

±

10V Max. 

Output Impedance 

50 

Ω

 

Summary of Contents for DDS-3005 USB

Page 1: ...User s Guide DDS 3005 USB Operation Manual...

Page 2: ...ments 3 2 2 Shape and Terminal Illustration 3 Chapter 3 Software Operations 6 3 1 Installing the Hardware 6 3 2 Installing the Software 9 3 3 Run the DDS 3005 USB 10 3 4 Choose the Wave Forms 10 3 5 W...

Page 3: ...antages of high frequency accuracy high waveform resolution high reliability and wide software support It can be widely used in the various kinds of electronics labs and it offers complete interface f...

Page 4: ...racy Time Base Error 1 Count Input Impedance 50K Frequency Counter Channel 2 Range 25MHz 2 7GHz Input Power 20dbm Coupling Mode AC Accuracy Time Base Error 1 Count Input Impedance 50 Standard Frequenc...

Page 5: ...XP Memory 128Mbyte Graphic Card Microsoft DirectX supported Screen resolution 1024x768 Color depth 16bit l Recommended System Requirements Operating System Windows 98 2000 XP Memory 256Mbyte Graphic C...

Page 6: ...4 DDS 3005 USB Shape...

Page 7: ...PIN7 Bit1 PIN8 Bit0 PIN9 Synchronized Signal Output PIN10 Digital Ground Digital Output Port Definition PIN1 Bit7 PIN2 Bit6 PIN3 Bit5 PIN4 Bit4 PIN5 Bit3 PIN6 Bit2 PIN7 Bit1 PIN8 Bit0 PIN9 External Tr...

Page 8: ...ent to the USB port through the USB cable the PC prompts that new USB device is found The PC will automatically find the new USB device and choose the nominated directory to install the driver Choose...

Page 9: ...7 Click Continue to finish the installation...

Page 10: ...8 The system will notify that the new USB device can work normally now After the successfully installation in the Device Manager you can see the DDS 3005 USB device...

Page 11: ...9 3 2 Installing the Software The setup software of DDS 3005 USB is in the CD run the Setup exe to install the software...

Page 12: ...ms Press down any button of certain waveform to switch to the output of such kind of waveform When switch to arbitrary waveform from other kind of waveform the edition work can be done on the original...

Page 13: ...o measure by the buttons shown as below Including High Frequency Low Frequency Coupling Mode Frequency Measure Counter and the function s On Off 3 7 Waveform Output Control By the following buttons to...

Page 14: ...he draw the waveform 3 9 Waveform Data Files The data format of DDS 3005 USB is CSV Its format is compatible with the CSV file produced by the Tektronix ARBExpress software User can edit or set up the...

Page 15: ...13 strong electrical field and static may cause the abnormal working or even damage to the instrument...