Troubles
Possible causes
Eliminate methods
No argon flows out after
pressing the torch switch
Switch of argon bottle or
flowmeter doesn’t open up
Open up these two switches
Gas tube is jammed or broken
Check tube
Gas valve is broken
Change valve
Can’t close relay J3(4123) in
board AP1
Change relay J3(4123) or board
AP1
Can’t adjust welding current Potentiometer for adjusting
current is broken or wire is
disconnected
Change potentiometer or
connect wire
B1 in board AP1 is broken
Change B1 or board AP1
Rated output current is
reduced
Input voltage is too low
Ensure the normal voltage
Input wire is too thin
Change power supply wire
Capability of power supply is not
enough
Ensure the capability of power
supply more than the maximal
power of machine in normal
work condition
Function “pulsed TIG
welding” does not exist
One of the base current, summit
current or pulse frequency
potentiometers is broken
Check and change the broken
potentiometers
M1(4011),N1(555),B1(339) in
board AP1 is broken
Change M1(4011),N1(555),
B1(339) or board AP1
Inverter tube (IGBT) is
broken
Work in over loading condition
for a long time
Change IGBT
Work in over voltage or under
voltage condition for a long time
Change IGBT and ensure the
normal input voltage
Output commutation diode
is broken
Work in great current condition
for a long time or environment
temperature is too high
Change broken diode and
improve work condition
Frequent burnout of diode is
caused by the large discharging
space of arc-igniting unit.
Adjust the discharging space to
1.0-1.2mm