Page EN-38
Troubleshooting table
Error indicators
Code
Solution
E1
:
It takes too long for the
water to fill up.
Turn the water tap on completely.
Arrange the inlet hose properly so that it is not kinked
(see „Connecting the inlet hose“ on page EN-29).
Ensure that the water pressure is correct. See „Technical specifi-
cations“ on page EN-41.
E3
:
The heating element is
defective.
Have the appliance examined and repaired.
E4
:
Water overflow
Switch off the tap. Find the gap in the seal (or have someone find
it) and repair the leak (or have it repaired).