Start-up
Page EN-32
1. Move the appliance using a wheeled
platform for furniture and with a second
person.
2. Unpack the appliance and carefully re-
move all packaging, plastic profiles, adhe-
sive strips, protective film and foam pad-
ding from the inside, outside and reverse
of the appliance.
3. Select a suitable location and adhere to
the stipulated minimum distances and
ambient temperatures (see below).
Space required according to the appliance
dimensions
A:
833 mm
B:
1775 mm
C:
300 mm
D: 740 mm
E:
1085 mm
F:
100 mm
G:
100 mm
H: 130°
I:
720 mm
To prevent the formation of a flammable gas-
air mixture in the event of a leakage in the re-
frigeration circuit, the installation space must
have the following minimum size:
– for appliances of 70 g refrigerant
9 m
3
– for appliances of 90 g refrigerant
12 m
3
You will find information about the indicated
amounts of refrigerant on the data sheet on
page EN-40.
Suitable locations are dry, well-ventilated ar-
eas that are cool if possible. Unsuitable loca-
tions are ones with direct sunlight or which
are directly next to an oven, hob or radiator.
The following minimum distances must be
maintained:
– from electrical hobs
10 cm
– from oil and coal burning stoves
10 cm
– from other cooling appliances
10 cm
– from washing
machines/dishwashers
10 cm
WATER DISPENSER
Space requirement diagram (when the door is open and when the door is closed)