4
English
Assembly
(see page 35)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 41)
To adjust the hot water limiter. Using a hot water limiter in
combination with a continuous flow water heater is not
recommended.
Maintenance
(see page 48)
The check valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions
(see page 42)
Flow diagram
(see page 43)
Spare parts
(see page 47)
XXX = Colors
000 = Chrome Plated
340 = Brushed Black Chrome
670 = Matt Black
800 = Stainless Steel Optic
Special accessories
(order as an extra)
Adapter (G⅜ / G½)
#93395000 (see page 47)
Cleaning
(see page 44)
Operation
(see page 44)
Hansgrohe recommends not to use as drinking water the
first half liter of water drawn in the morning or after a
prolonged period of non-use.
Test certificate
(see page 48)
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping in area of swivel
spout
- O-ring defective
- Exchange O-ring
Water escaping at the threaded base - connection hoses not completely
screwed into basic body
- Tighten connection hoses by hand
- O-ring at the connection hose
defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Summary of Contents for Talis M54 210 2jet 72800 Series
Page 35: ...35 max 45 mm 1a 2 3 Nm max 70 mm 1b 150 110 6a 6d 6b 6c 5 3 SW 8 mm SW 19 mm 4 Nm 4 60 360...
Page 36: ...36 150 45 105 75 75 45 105 24 x 15 6a...
Page 37: ...37 24 x 15 6b 110 25 85 55 55 25 85 110...
Page 38: ...38 24 x 15 6c 60 45 15 30 30 60...
Page 39: ...39 6d 360 1 2 3 7 8 Armaturenfett Grease 1 2...
Page 40: ...40 80 CLICK 2 min 1 2 3 1 2 9 10 11 12 13 2 3 A r m a t u r e n f e t t G r e a s e 1...
Page 49: ...santehnica ru...