Warning / Alert
Alert Message
Description / Solution
Low outlet pressure (shutdown)
Low outlet pressure! Check
sensor!
A low outlet pressure shutdown will occur when the outlet pressure
reads at below 1 psi for more than 5-10 seconds (depending on
outlet flow). The unit will automatically shut down and remain in
this state until outlet pressure is restored for a minimum of 30
seconds.
This may be caused by a failure in the outlet pressure sensor or an
issue downstream from the unit.
If the issue persists, contact Customer Service.
High outlet pressure (shutdown)
Outlet pressure too
high! Check IMMEDIATELY!
Pump will be re-enabled when
pressure <70 PSI
The system is designed to prevent over-pressurization by prevent
pump operation when the outlet pressure is above 80 psi.
High Inlet TDS
ALERT!! Elevated Inlet TDS!
The system is not designed to handle inlet water TDS above 3000
(1500 TDS for Model 2R).
Confirm that the inlet water TDS is below 3000. If so, replace the
inlet TDS sensor and confirm the inlet water TDS settings under
the setup screen.
High Outlet TDS
ALERT!! Elevated Outlet TDS!
Outlet TDS is above 500
.
If the outlet TDS is above this threshold
the system with continue to operate but in an active alert state.
If the alert state persists, contact Customer Service.
Warnings / Alerts (continued)