Warnings / Alerts (continued)
The following table lists the potential warnings / alerts that may appear and provides a description / potential
solution.
The top left corner of the universal banner on the display screen will read ‘
Check alerts
’ when there is an
active alert present. The message will remain on the banner and the alert will remain on the alerts screen until the
condition no longer exists.
To view details of any active warning or alert(s), go to the Alerts ('Alrt') screen.
Warning / Alert
Alert Message
Description / Solution
Low inlet pressure
Warning! Inlet pressure is too
low!
Check the inlet water supply (water being fed to the system) and
make sure any necessary valves leading to the system are open.
If a valve is closed, please open it to allow water to flow. Make
sure the inlet water is not leaking.
If you have a well, check for proper pressure in the well tank,
making sure that the circuit breaker on the well pump is switched
on. Ensure water is flowing through the well pump properly.
Ensure you have a 40/60 well tank pressure switch.
Set the
minimum bound of the switch to 45 psi for best performance.
High inlet pressure
Water inlet pressure is too high!
Check the inlet water supply (water being fed to the system) and
make sure the pressure is not over 60 psi. If the inlet pressure is
above 60 psi, a pressure regulating valve (PRV) will need to be
installed.
If you have a well, check for proper pressure in the well tank,
make sure that the well pump pressure switch is properly suited
for this application (i.e. 40-60 psi).