Fault
Cause
Remedy
Insufficient water
-
-
-
Supply pressure inadequate
Regulator filter dirty
Shower filter seal dirty
-
-
-
Check mains pressure
Clean filters
Clean filter seal between shower
and hose
Crossflow, hot water being
forced
into cold water pipe, or vice
versa, when mixer is closed
- Backflow preventers dirty or
leaking
- Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
-
-
Thermostat has not been
adjusted
Hot water temperature too low
-
-
Adjust thermostat
Increase hot water temperature
to 42 °C to 65 °C
Temperature regulation not
possible
-
-
Temperature regulator dirty or
calcified
For new installations: basic
body incorrectly connected
(should be: cold right, hot left)
or installed with 180° rotation
-
-
Clean temperature regulator,
exchange if necessary
Install function block turned
through 180°
Safety stop button not operating
-
-
Spring defective
Button calcified
- Clean spring and/or button,
exchange if necessary