background image

8

Seal the wall around the anchors 

with waterproof sealant.
Failure to seal the wall can lead 

to possible water damage.
Be careful not to drill into water 

lines!

9

10

11

12

6 mm

Summary of Contents for ShowerArc 26396001

Page 1: ...ShowerArc 26396001 Installation Instructions Warranty...

Page 2: ...ShowerArc 26396001 Minimum ceiling height 90 1 2...

Page 3: ...ecommended hot water temp 120 140 F Max hot water temp 165 F Flow rate showerhead 2 5 gpm bodysprays 0 6 gpm each handshower 2 5 gpm The thermostatic mixing valve has a high temperature limit stop whi...

Page 4: ...installation Requires 26397000 installation kit included Instructions begin on page 13 Roughing in The ShowerArc requires 1 2 NPT female fittings recessed 3 8 behind the surface of the finished wall f...

Page 5: ...of supplies is required do not install two sets of supplies Installation in 90 corner The thermostatic mixing valve may be installed on either wall This diagram shows both possible positions for the...

Page 6: ...Installation in 90 Corner Seal the wall around the supplies with waterproof sealant Failure to seal the wall can lead to possible water damage 1 2 3 4...

Page 7: ...Seal the wall around the anchors with waterproof sealant Failure to seal the wall can lead to possible water damage 5 6 7 8...

Page 8: ...Seal the wall around the anchors with waterproof sealant Failure to seal the wall can lead to possible water damage Be careful not to drill into water lines 9 10 11 12 6 mm...

Page 9: ...13 14 15 16...

Page 10: ...10 1 2 17 18 19 20 6 mm...

Page 11: ...11 Seal the wall around the anchors with waterproof sealant Failure to seal the wall can lead to possible water damage 1 2 21 22 23 24 6 mm...

Page 12: ...12 Turn to page 22 to continue the installation Seal the wall around the anchors with waterproof sealant Failure to seal the wall can lead to possible water damage 25 26...

Page 13: ...static mixing valve may be installed on either wall The diagram shows both possible positions for the installation Only one set of supplies is required do not install two sets of supplies Wall to Wall...

Page 14: ...14 Wall to Wall Installation Seal the wall around the supplies with waterproof sealant Failure to seal the wall can lead to possible water damage 1 2 3 4...

Page 15: ...15 Seal the wall around the anchors with waterproof sealant Failure to seal the wall can lead to possible water damage 5 6 7 8...

Page 16: ...16 Seal the wall around the anchors with waterproof sealant Failure to seal the wall can lead to possible water damage Be careful not to drill into water lines 1 2 6 mm 12 9 10 11...

Page 17: ...17 Install the 26397000 mounting set 13 14 15 16...

Page 18: ...18 XX 90 XX 17 18 19 20...

Page 19: ...19 6 mm SW 3 mm M6x8 1 2 24 21 22 23...

Page 20: ...20 Install the 26397000 mounting set M6x60 1 2 3 SW 3 mm M6x8 25 26 27 6 mm 28 Seal the wall around the an chors with waterproof sealant Failure to seal the wall can lead to possible water damage 1 2...

Page 21: ...21 Turn to page 22 to continue the installation SW 3 mm M6x8 29...

Page 22: ...22 Install the Cover Escutcheon and Handle Install the Showerhead and Handshower 2 1...

Page 23: ...handle screw with a 3 mm Allen wrench Remove the retainer clip and stop ring from the stem Turn the stop unit to the handshower position Turn the temperature control stem until the output water is the...

Page 24: ...urn the stop unit to the off position Install the stop ring so that the tooth is against the stop Install the clip Install the handle Tighten the handle screw with a 3 mm Allen wrench KLICK SW 3 mm 5...

Page 25: ...ature control knob until the output water is 100 F Turn the diverter handle to the off position Loosen the handle screw with a 3 mm Allen wrench Remove the handle Align the indexing mark on the temper...

Page 26: ...counter clockwise to make the water warmer When the knob is turned counter clockwise to the 100 position it will stop To obtain water hotter than 100 push the knob in and continue turning it counter...

Page 27: ...ime shown in the label instructions Rinse the spray face with clear water Reinstall the handshower Flush the handshower for at least one minute before using The handshower uses the Rubit cleaning syst...

Page 28: ...28 Replacement Parts 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 17 25...

Page 29: ...escutcheon 97491000 13 thermostat cartridge 94282000 14 noise reducer 94073000 15 ball s union 96742001 16 rear panel 97493000 17 cover 97494000 18 sleeve nut 97492000 19 pipe elbow 97495000 20 pipe 9...

Page 30: ...erature is erratic thermostat cartridge is faulty replace thermostat cartridge Water drips for several min utes after the unit is turned off not a product defect normal clearing of showerhead not a pr...

Page 31: ...to comply with the needs of the market with regard to design and functionality To avoid damage and returns it is necessary to consider certain criteria when cleaning Cleaning Materials for Faucets and...

Page 32: ...date and place of purchase 2 A description of the problem 3 Delivery of the product or the defective part postage prepaid and carefully packed and insured to Hansgrohe Inc 1492 Bluegrass Lakes Parkwa...