English
Assembly see page 60
Fault
Cause
Remedy
Insufficient water
- Supply pressure inadequate
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Regulator filter dirty
- Clean filters
- Shower filter seal dirty
- Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
- Backflow preventers dirty or
leaking
- Clean backflow preventers,
exchange if necessary
Spout temperature does not
correspond with temperature set
- Thermostat has not been adjusted
- Adjust thermostat
- Hot water temperature too low
- Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible - Temperature regulator dirty or
calcified
- Clean temperature regulator,
exchange if necessary
- For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180º rotation
- Install function block turned through
180º
Safety stop button not operating
- Spring defective
- Button calcified
- Clean spring and/or button,
exchange if necessary
Valve stiff
- Shut-off unit damaged
- Exchange shut-off unit
Shower or spout dripping
- Dirt or sedimentation on valve seat,
shut-off unit damaged
- Clean or exchange shut-off unit
Summary of Contents for PuraVida 15775 Series
Page 60: ...60 1 2 3 4 5 6 1 2 3 ...
Page 61: ...61 7 8 1 2 3 4 PuraVida 15775XXX ...
Page 62: ...62 z B 42 C for example 42 C 4 3 1 2 2 1 6 1 2 5 SW 3 mm 2 Nm ...
Page 63: ...63 1 3 2 ...
Page 64: ...64 6 2 3 4 1 5 1 1 2 1 2 2 3 4 ...
Page 65: ...65 5 1 2 3 4 8 9 10 11 7 1 2 ...